ANALISIS TEKNIS DAN EKONOMIS PENGOPRASIAN PENERANGAN JALAN...

21
TUGAS AKHIR ANALISIS TEKNIS DAN EKONOMIS PENGOPRASIAN PENERANGAN JALAN UMUM MENGGUNAKAN SOLAR CELL UNTUK KEBUTUHAN PENERANGAN DI JALAN BY PASS I GUSTI NGURAH RAI I WAYAN HENDRA SETIAWAN JURUSAN TEKNIK ELEKTRO FAKULTAS TEKNIK UNIVERSITAS UDAYANA BUKIT JIMBARAN 2015

Transcript of ANALISIS TEKNIS DAN EKONOMIS PENGOPRASIAN PENERANGAN JALAN...

TUGAS AKHIR

ANALISIS TEKNIS DAN EKONOMIS

PENGOPRASIAN PENERANGAN JALAN UMUM

MENGGUNAKAN SOLAR CELL UNTUK

KEBUTUHAN PENERANGAN DI JALAN BY PASS

I GUSTI NGURAH RAI

I WAYAN HENDRA SETIAWAN

JURUSAN TEKNIK ELEKTRO

FAKULTAS TEKNIK UNIVERSITAS UDAYANA

BUKIT JIMBARAN

2015

ii

TUGAS AKHIR

ANALISIS TEKNIS DAN EKONOMIS

PENGOPRASIAN PENERANGAN JALAN UMUM

MENGGUNAKAN SOLAR CELL UNTUK

KEBUTUHAN PENERANGAN DI JALAN BY PASS

I GUSTI NGURAH RAI

I WAYAN HENDRA SETIAWAN

NIM : 1004405027

JURUSAN TEKNIK ELEKTRO

FAKULTAS TEKNIK UNIVERSITAS UDAYANA

BUKIT JIMBARAN

2015

iii

ANALISIS TEKNIS DAN EKONOMIS PENGOPRASIAN PENERANGAN

JALAN UMUM MENGGUNAKAN SOLAR CELL UNTUK KEBUTUHAN

PENERANGAN DI JALAN BY PASS I GUSTI NGURAH RAI

PRASYARAT GELAR

Skripsi Diajukan Sebagai Prasyarat untuk Memperoleh Gelar Sarjana SI (Strata 1)

pada Jurusan Teknik Elektro Fakultas Teknik Universitas Udayana

I WAYAN HENDRA SETIAWAN

1004405027

JURUSAN TEKNIK ELEKTRO

FAKULTAS TEKNIK UNIVERSITAS UDAYANA

BUKIT JIMBARAN

2015

iv

LEMBAR PERNYATAAN ORISINALITAS

Skripsi ini adalah hasil karya saya sendiri, dan semua sumber baik yang dikutip

maupun dirujuk telah saya nyatakan dengan benar.

Nama : I Wayan Hendra Setiawan

NIM : 1004405027

Tanda Tangan :

Tanggal : 2 Juli 2015

v

LEMBAR PENGESAHAN

Skripsi ini diajukan oleh :

Nama : I Wayan Hendra Setiawan

NIM : 1004405027

Jurusan : Teknik Elektro

Judul Skripsi : Analisis Teknis dan Ekonomis Pengoprasian Penerangan Jalan

Umum Menggunakan Solar Cell Untuk Kebutuhan Penerangan di

Jalan By Pass I Gusti Ngurah Rai

Telah berhasil dipertahankan di hadapan Dewan Penguji dan diterima

sebagai bagian persyaratan yang diperlukan untuk memperoleh gelar

Sarjana Teknik (ST) pada Jurusan Teknik Elektro, Fakultas Teknik,

Universitas Udayana

DEWAN PENGUJI

Pembimbing I : Ir. I Wayan Rinas, MT. ( )

Pembimbing II : I Made Suartika, ST. ( )

Penguji : Ir. I Wayan Arta Wijaya, M.Erg, MT. ( )

Penguji : Ir. I Gusti Ngurah Janardana, M.Erg. ( )

Penguji : Ir. Antonius Ibi Weking, MT. ( )

Ditetapkan di : Bukit Jimbaran, Badung

Tanggal : Agustus 2015

Mengetahui

Ketua Jurusan Teknik Elektro

Ir. I Nyoman Setiawan, MT

NIP. 196312291991031001

vi

UCAPAN TERIMA KASIH

Puji syukur penulis panjatkan ke hadapan Ida Sang Hyang Widhi Wasa,

Tuhan Yang Maha Esa atas karunia-Nya sehingga penulis dapat menyelesaikan

Skripsi ini. Skripsi ini berjudul “ANALISIS TEKNIS DAN EKONOMIS

PENGOPRASIAN PENERANGAN JALAN UMUM MENGGUNAKAN

SOLAR CELL UNTUK KEBUTUHAN PENERANGAN DI JALAN BY PASS

I GUSTI NGURAH RAI”.

Skripsi ini disusun untuk memenuhi salah satu syarat dalam menyelesaikan

pendidikan sarjana strata satu (S1) pada Jurusan Teknik Elektro Fakultas Teknik

Universitas Udayana.

Penulis menyadari bahwa dalam menyelesaikan Skripsi ini tidak terlepas

dari bantuan berbagai pihak yang telah memberikan dukungan baik moril maupun

materiil. Pada kesempatan ini penulis menyampaikan ucapan terima kasih kepada:

1. Bapak Prof. Ir. Ngakan Putu Gede Suardana, MT, PhD. selaku Dekan

Fakultas Teknik Universitas Udayana.

2. Bapak Ir. I Nyoman Setiawan, MT. selaku Ketua Jurusan Teknik Elektro

Fakultas Teknik Universitas Udayana.

3. Bapak Ir. I Wayan Rinas, MT. Selaku dosen pembimbing I yang telah banyak

memberikan arahan, waktu, semangat serta saran-saran selama penyusunan

laporan.

4. Bapak I Made Suartika, ST. selaku Dosen Pembimbing II yang telah banyak

memberikan bantuan dan saran serta bimbingan dalam penulisan Skripsi.

5. Bapak dan Ibu dosen pengajar, para Pegawai serta Staf Teknisi Program Studi

Teknik Elektro atas sumbangsih ilmu pengetahuan dan bimbingan selama

menempuh kuliah di Jurusan Teknik Elektro.

6. Bapak Ida Bagus Muter, beserta Staff di DISHUBKOMINFO yang telah

banyak memberikan masukan-masukan dan informasi yang menunjang dalam

penyusunan Skripsi ini.

7. Orang Tua tersayang, Kakak dan anggota keluarga besar yang telah

memberikan dukungan moril dan material selama penyusunan skripsi ini.

vii

8. Ni Putu Dewi Cahyaningsih sayang, Semeton Gardu : I Made Adi

Sudiatmika, I Gede Ariana, Made Ananta Pradnya, serta semeton FPMHD -

Unud yang selalu menemani serta memberikan semangat dan motivasi selama

penyusunan skripsi ini.

9. Teman-teman Elektro angkatan 2010 yang turut membantu dan memberikan

semangat dalam penulisan Skripsi ini.

10. Serta semua pihak yang tidak bisa penulis sebutkan satu-persatu atas bantuan

dan saran yang diberikan sehingga laporan ini bisa selesai tepat pada

waktunya.

Penulis menyadari masih terdapat kekurangan dalam Skripsi ini, saran-

saran yang membangun sangat diharapkan untuk menyempurnakan Skripsi ini.

Akhir kata penulis mengharapkan semoga Skripsi ini dapat memberikan

kontribusi dalam pengembangan ilmu pengetahuan yang bermanfaat bagi

kita semua.

Denpasar, 10 Juli 2015

Penulis

viii

ABSTRAK

Penggunaan energi listrik konvensional akan berdampak pada krisis energi

dan juga berdampak pada kerusakan lingkungan hidup karena bersifat tidak dapat

diperbaharui. Salah satu bentuk energi alternatif yang dapat diperbaharui untuk

mengurangi terjadinya krisis energi serta kerusakan lingkungan hidup yaitu energi

matahari. Dinas Perhubungan, Komunikasi, dan Informatika, Kabupaten Badung

mengupayakan penghematan energi listrik konvensional melalui penerapan solar

cell 160 Watt Peak sebagai sumber energi listrik khusus untuk penerangan pada

jalan By Pass I Gusti Ngurah Rai sepanjang 9,4 km dari bundaran patung I Gusti

Ngurah Rai sampai Nusa Dua. Pemasangan solar cell di jalan by pass I Gusti

Ngurah Rai mengikuti arah jalan sehingga terdapat 4 jenis arah kemiringan solar

cell yang akan berdampak perbedaan pada keluaran arus dan tegangan panel

surya.

Dalam penelitian ini dilakukan analisis secara teknis maupun ekonomis

penerapan solar cell pada lampu penerangan jalan umum di jalam By Pass I gusti

Ngutrah Rai untuk mengetahui pengaruh perbedaan arah kemiringan solar cell

terhadap arus dan tegangan pengisian baterai solar cell serta pengaruh arah

kemiringan solar cell terhadap konsumsi energi lampu LED. Penelitian dilakukan

7 hari yaitu dari tanggal 22 – 28 Pebruari 2015 dengan monitoring tegangan dan

arus yang dhasilkan oleh panel surya, serta monitoring kondisi cuaca lingkungan.

Berdasarkan hasil perhitungan diperoleh sudut kemiringan yang

maksimum untuk penyerapan intensitas matahari yaitu 14,7 namun sudut

kemiringan di lokasi panel surya yaitu 10. Dari pengukuran 4 jenis arah

kemiringan solar cell yaitu arah barat laut, barat, selatan dan barat daya diperoleh

perbandingan hasil tegangan keluaran solar cell maksimum pada solar cell

dengan arah kemiringan barat pada sudut kemiringan 10 sebesar 19,49 V, serta

arus keluaran solar cell maksimum pada solar cell dengan rah kemiringan barat

sebesar 1,64 A. sedangkan keluaran solar cell terrendah terdapat pada panel surya

dengan arah kemiringan selatan pada sudut kemiringan 10, yaitu tegangan

sebesar 14,07 V serta Arus sebesar 0, 79 A. Kemudian dengan rumus dan data

pendukung lainnya dilakukan perhitungan yang menghasilkan konsumsi energi

lampu LED 57 W yang digunakan lampu penerangan jalan umum di jalan by pass

I Gusti Ngurah Rai yaitu sebesar 57Ah selama 12 jam , hal tersebut dapat

terpenuhi oleh kapasitas baterai yang terpasang yaitu 200 Ah dengan produksi

energi terrendah yaitu 79 Ah per hari.

Kata Kunci : Solar cell, Produksi Energi, dan Lampu Penerangan Jalan Umum.

ix

ABSTRACT

The use of conventional electrical energy will have an impact on the

energy crisis and also have an impact on the environmental damage due to non-

renewable. One form of alternative renewable energy to reduce the energy crisis

and the environmental damage that the sun's energy. Department of

Transportation, Communications, and Information Technology Badung seek

conventional electrical energy savings through the implementation of a solar cell

160 Watt Peak as a special source of electrical energy for lighting on By Pass I

Gusti Ngurah Rai Street along 9.4 km from I Gusti Ngurah Rai roundabout

sculpture to Nusa Dua. Installation of the solar cell on the I Gusti Ngurah Rai

street follow the direction of the road with the result that there are four types of

solar cell slope direction diverification that will impact the current and voltage

output of solar panels.

In this research, conducted technical and economic analysis the application of

solar cell on a public street lighting lamps in the I Gusti Ngurah Rai street to determine

the effect of different slope direction of the solar cell to the battery charging current and

voltage of the solar cell and influence the direction of the slope of the solar cell to the

energy consumption LED lights. Research conducted 7 days from the date of 22-28

February 2015 by monitoring the voltage and current generated by solar panels, as well

as environmental monitoring weather conditions.

From measurements of 4 different types of solar cell slope direction which,

direction of northwest, west, south and southwest, the comparison of the results of

the maximum output voltage of the solar cell in the solar cell with direction of the

west slope is 19.49 V, and output current of the solar cell the maximum in the

solar cell with direction of the west slope is 1.64 A. Whereas, output of the lowest

solar cell, was located on the solar panel of the southern slope direction, with a voltage

of 14.07 V and the current of 0, 79 A. Furthermore, with formulas and other supporting

data was calculated which the results in energy consumption 57 W LED lamp is used as a

public street lighting on the I Gusti Ngurah Rai street is 57Ah for 12 hours, it can be

fulfilled by the installed battery capacity is 200 Ah with the lowest possible energy

production is 79 Ah per day.

Keywords: Solar Cell, Energy Production, and Street Lightning Lamp,

x

DAFTAR ISI

SAMPUL DALAM ............................................................................................ i

LEMBAR PERNYATAAN ORISINALITAS .................................................. ii

PRASYARAT GELAR....................................................................................... iii

LEMBAR PENGESAHAN................................................................................. v

UCAPAN TERIMA KASIH .............................................................................. vi

ABSTRAK.......................................................................................................... viii

ABSTRACT........................................................................................................ ix

DAFTAR ISI ..................................................................................................... x

DAFTAR GAMBAR ....................................................................................... xiii

DAFTAR TABEL ............................................................................................ xv

DAFTAR SINGKATAN DAN LAMBANG .................................................. xvii

DAFTAR LAMPIRAN……………………………………………………….. xix

BAB I PENDAHULUAN ............................................................................... 1

1.1 Latar Belakang ................................................................................. 1

1.2 Rumusan Masalah ............................................................................ 3

1.3 Tujuan Penelitian ............................................................................. 3

1.4 Manfaat Penelitian ........................................................................... 3

1.5 Batasan Masalah ........................................................................... 4

1.6 Sistematika Penulisan ...................................................................... 4

BAB II KAJIAN PUSTAKA ..................................................................... 6

2.1 State of The Art Review ................................................................... 6

2.2 Jalan .................................................................................................. 7

2.2.1 Klasifikasi Jalan……………...................................................... 7

2.2.2 Volume Lalu lintas .................................................................. 8

2.2.3 Kecepatan Rencana.................................................................... 9

2.3 Kuat Penerangan ….......................................................................... 9

2.4 Lampu Penerangan Jalan Umum .................................................... 10

2.5 Fungsi Lampu Penerangan Jalan .................................................... 11

xi

2.6 Instalasi Penerangan Jalan Umum ................................................... 12

2.6.1 Pemasangan PJU dengan cara under ground kabel (kabel

bawah tanah).......................................................... ................... 12

2.6.2 Penyambungan kabel atau penghantar pada PJU....................... 13

2.6.3 PHB pada instalasi penerangan jalan umum............................... 13

2.6.3 Arde dan Penghantar Proteksi ……………................................ 14

2.7 Satuan Penerangan Sistem Internasional.............................................. 14

2.8 Spesifikasi Lampu Penerangan Jalan…............................................... 14

2.9 Penempatan Lampu Penerangan.......................................................... 18

2.10 Tiang Lampu Penerangan jalan ......................................................... 21

2.11 Jenis Lampu Penerangan Jalan Umum ........................................ 24

2.12 Penataan Penempatan Lampu Jalan...................................................... 27

2.13 Dasar Pencahayaan .......................................................................... 27

2.13.1 Arus Cahaya / Fluks Cahaya ................................................. 27

2.13.2 Intensitas Cahaya.................................................................... 28

2.13.3 Iluminasi .............................................................................. 28

2.13.4 Efikasi Cahaya ..................................................................... 29

2.14 Konsumsi energi …........................................................................... 29

2.14.1 Daya Lampu Total ….............................................................. 29

2.14.2 Daya Lampu Tiap Bulan …..................................................... 30

2.14.3 Biaya Pemakaian Energi …..................................................... 30

2.15 Potensi Matahari…............................................................................. 30

2.16 Solar Cell ………............................................................................. 32

2.17 Jenis-Jenis Panel Surya...................................................................... 33

2.18 Solar change controller ................................................................... 35

2.19 Baterai .............................................................................................. 36

2.20 Sistem Solar Cell LPJU .................................................................... 37

2.21 Inklinasi dan Orientasi Panel Surya ................................................. 39

BAB III METODE PENELITIAN .................................................................... 40

3.1 Lokasi dan Waktu Penelitian .............................................................. 40

3.2 Sumber dan Jenis Data Penelitian........................................................ 41

xii

3.2.1 Sumber Data ............................................................................... 41

3.2.2 Jenis Data.................................................................................... 41

3.3 Tahapan Penelitian…………............................................................... 42

3.4 Alur Analisis......................................................................................... 43

BAB IV PEMBAHASAN………....................................................................... 44

4.1 LPJU By Pass I Gusti Ngurah Rai Sebelum Menggunakan

Solar Cell…………………….……………………..…………..…… 44

4.2 LPJU Solar Cell By Pass I Gusti Ngurah Rai………………..……… 46

4.3 Klasifikasi Intensitas Penerangan………………………………...…. 50

4.4 Menentukan Penerangan yang Diperlukan pada Jalan By Pass

I Gusti Ngurah Rai……………….…….………………….…..……. 50

4.4.1 Pemilihan lampu penerangan jalan…………………..…..….. 50

4.4.2 Perbandingan Penggunaan Lampu Sodium Jenis SON-T 150W

dengan LED Philips Solar Green Vision Family 57 W...…….. 52

4.5 Sistem Instalasi……………………………………………………… 54

4.6 Analisa Sudut dan arah kemiringan panel surya…………………… 56

4.7 Pengukuran arus dan tegangan pembangkitan………………………. 59

4.8 Hasil pengukuran arus tengangan pembangkitan…………………… 60

4.9 Analisa efektifitas solar cell terhadap produksi energi……………… 78

4.10 Kebutuhan daya 1 unit LPJU solar cell di Jalan By Pass I Gusti…… 82

4.11 Analisa kapasitas Baterai LPJU solar cell By pass Ngurah Rai…….. 83

4.12 Perbandingan konsumsi energi Lampu LED dengan Lampu

Sodium ( SON-T)………………….……….…………….…............. 92

BAB IV PENUTUP…….. ….…......................................................................... 94

5.1 Simpulan ………………………………………………...……......... 94

5.2 Saran….. …………………………………………………………… 95

DAFTAR PUSTAKA………...........................................................................… 96

LAMPIRAN…………………............................................................................ 98

xiii

DAFTAR GAMBAR

Gambar 2.1 Penempatan Lampu Penerangan..................................................... 19

Gambar 2.2 Tipikal Tiang Lampu Dengan Lengan Tunggal.............................. 21

Gambar 2.3 Tipikal Tiang Lampu Dengan Lengan Ganda................................. 22

Gambar 2.4 Tipikal Tiang Lampu Tegak Tanpa Lengan.................................... 23

Gambar 2.5 Penentuan sudut kemiringan stang ornamen terhadap lebar Jalan.. 24

Gambar 2.6 Garis peredaran matahari semu tahunan.......................................... 31

Gambar 2.7 Kelas Teknologi Sel Surya.............................................................. 33

Gambar 2.8 Modul Surya Polycrystalline........................................................... 34

Gambar 2.9 Modul Surya Monocrystalline......................................................... 34

Gambar 2.10 Modul Surya Thin Film................................................................. 35

Gambar 2.11 Solar change controller................................................................. 36

Gambar 2.12 Lampu Penerangan Jalan Umum Mengguankan Solar Cel.......... 37

Gambar 2.13 Konfigurasi Dasar System Lampu Penerangan Jalan Solar Cell... 38

Gambar 2.14 Kombinasi inklinasi dan orientasi menentukan eksposisi

panel surya..................................................................................... 39

Gambar 4.1 LPJU By Pass I Gusti Ngurah Rai………………………………… 45

Gambar 4.2 Lampu penerangan jalan umum solar cell tipikal tiang lampu

dengan lengan tunggal (kiri) dan tipikal tiang lampu dengan

lengan ganda (kanan) di Jalan By Pass I Gusti Ngurah Rai…..… 46

Gambar 4.3 Sistem instalasi lampu penerangan jalan umum solar cell tipikal

tiang lampu dengan lengan ganda…...…………..………………. 47

Gambar 4.4 Sistem instalasi lampu penerangan jalan umum solar cell tipikal

tiang lampu dengan lengan tunggal……………………………... 48

Gambar 4.5 Single line Sistem instalasi lampu penerangan jalan umun solar

cell By pass I Gusti Ngurah Rai………………………………… 55

Gambar 4.6 Arah kemiringan LPJU solar cell By Pass Ngurah Rai pada zona

1, 2, 3, dan 4……………………………………………………… 57

xiv

Gambar 4.7 Denah lokasi penelitian LPJU solar cell By Pass Ngurah Rai…..58

Gambar 4.8 Konstruksi penyangga modul surya LPJU solar cell By Pass

Ngurah Rai………………………………………………………. 59

Gambar 4.9 Pemasangan alat ukur untuk pengukuran arus dan tegangan

yang dibangkitkan oleh solar cell……………………......……... 60

Gambar 4.10 Grafik Perbandingan pembangkitan tegangan rata-rata solar

cell sampel 1, 2, 3, dan 4 pada tanggal 22 Pebruari 2015…....... 62

Gambar 4.11 Grafik Perbandingan pembangkitan arus rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 22 Pebruari 2015……......... 63

Gambar 4.12 Grafik Perbandingan pembangkitan daya rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 22 Pebruari 2015……......... 63

Gambar 4.13 Grafik Perbandingan pembangkitan tegangan rata-rata solar

cell sampel 1, 2, 3, dan 4 pada tanggal 23 Pebruari 2015…....... 65

Gambar 4.14 Grafik Perbandingan pembangkitan arus rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 23 Pebruari 2015……......... 65

Gambar 4.15 Grafik Perbandingan pembangkitan daya rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 23 Pebruari 2015……......... 65

Gambar 4.16 Grafik Perbandingan pembangkitan tegangan rata-rata solar

cell sampel 1, 2, 3, dan 4 pada tanggal 24 Pebruari 2015…....... 67

Gambar 4.17 Grafik Perbandingan pembangkitan arus rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 24 Pebruari 2015……......... 67

Gambar 4.18 Grafik Perbandingan pembangkitan daya rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 24 Pebruari 2015……......... 68

Gambar 4.19 Grafik Perbandingan pembangkitan tegangan rata-rata solar

cell sampel 1, 2, 3, dan 4 pada tanggal 25 Pebruari 2015…....... 62

Gambar 4.20 Grafik Perbandingan pembangkitan arus rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 25 Pebruari 2015……......... 63

Gambar 4.21 Grafik Perbandingan pembangkitan daya rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 25 Pebruari 2015……......... 63

Gambar 4.22 Grafik Perbandingan pembangkitan tegangan rata-rata solar

cell sampel 1, 2, 3, dan 4 pada tanggal 26 Pebruari 2015…....... 62

xv

Gambar 4.23 Grafik Perbandingan pembangkitan arus rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 26 Pebruari 2015……......... 63

Gambar 4.24 Grafik Perbandingan pembangkitan daya rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 26 Pebruari 2015……......... 63

Gambar 4.27 Grafik Perbandingan pembangkitan tegangan rata-rata solar

cell sampel 1, 2, 3, dan 4 pada tanggal 27 Pebruari 2015…....... 62

Gambar 4.28 Grafik Perbandingan pembangkitan arus rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 27 Pebruari 2015……......... 63

Gambar 4.29 Grafik Perbandingan pembangkitan daya rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 27 Pebruari 2015……......... 63

Gambar 4.30 Grafik Perbandingan pembangkitan tegangan rata-rata solar

cell sampel 1, 2, 3, dan 4 pada tanggal 28 Pebruari 2015…....... 62

Gambar 4.31 Grafik Perbandingan pembangkitan arus rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 28 Pebruari 2015……......... 63

Gambar 4.32 Grafik Perbandingan pembangkitan daya rata-rata solar cell

sampel 1, 2, 3, dan 4 pada tanggal 28 Pebruari 2015……......... 63

Gambar 4.33 Diagram perbandingan jumlah tiang lpju terhadap produksi

daya bulanan LPJU Solar cell By Pass I Gusti

Ngurah Rai………………………………………………….….. 77

Gambar 4.34 Grafik output arus solar cell sampel 1 pada saat cuaca cer…….. 79

Gambar 4.35 Hubungan kapasitas baterai dengan jam oprasional LPJU

solar cell pada sampel 1…………………………………...…… 80

Gambar 4.36 Grafik output arus solar cell sampel 2 pada saat cuaca cerah…. 81

Gambar 4.37 Hubungan kapasitas baterai dengan jam oprasional LPJU solar

cell pada sampel 2……………………………………………… 82

Gambar 4.38 Grafik output arus solar cell sampel 3 pada saat cuaca cerah.,,,. 83

Gambar 4.39 Hubungan kapasitas baterai dengan jam oprasional LPJU solar

cell pada sampel 3…………………………………………….... 84

Gambar 4.40 Grafik output arus solar cell sampel 4 pada saat cuaca cerah….. 85

Gambar 4.41 Hubungan kapasitas baterai dengan jam oprasional LPJU

solar cell pada sampel 4……………..……................................. 86

xvi

DAFTAR TABEL

Tabel 2.1 Klasifikasi Jalan Berdasarkan Fungsi, Kelas Beban Dan Tipe Medan. 7

Tabel 2.2 Penentuan Lebar Jalur dan Bahu Jalan…….......................................... 8

Tabel 2.3 Kecepatan Rencana Sesuai Klasifikasi Fungsi Jalan dan MedanJalan.. 9

Tabel 2.4 Klasifikasi Jalan..................................................................................... 9

Tabel 2.5 Rekomendasi Intensitas Penerangan Jalan……………...………......... 10

Tabel 2.6 Faktor Kehilangan Cahaya Lampu Penerangan Jalan Raya................. 11

Tabel 2.7 Faktor Perawatan Lampu...................................................................... 12

Tabel 2.8 Jenis Lampu Penerangan Jalan Ditinjau dari Karakteristik

dan Penggunaannya.............................................................................. 15

Tabel 2.9 Kode Indek Perlindungan IP ( Index of Protection )............................ 16

Tabel 2.10 Sistem Penempatan Lampu Penerangan Jalan................................... 18

Tabel 2.11 Lampu Penerangan Jalan Umum Mengguankan Solar Cel ........... . 36

Tabel 2.12 Jarak Antar Tiang Lampu Penerangan Berdasarkan Tipikal,

Distribusi Pencahayaan Dan Klasifikasi Lampu Pada Lampu Tipe A. 20

Tabel 2.13 Jarak Antar Tiang Lampu Penerangan Berdasarkan Tipikal

Distribusi Pencahayaan Dan Klasifikasi Lampu Pada Lampu Tipe B. 20

Tabel 2.14 Waktu kedudukan matahari.............................................................. 31

Tabel 2.15 Peak Hour per Day rata-rata daerah Bali.......................................... 22

xvii

Tabel 3.1 Jadwal Kegiatan............................................................................... 38

Tabel 4.1 Konsumsi daya LPJU By Pass I Gusti Ngurah Rai pada bulan

Januari 2013………………………………………………............… 44

Tabel 4.2 Spesifikasi Lampu LED LPJU solar cell By Pass Ngurah Rai…….. 49

Tabel 4.3 Spesifikasi Panel Surya LPJU solar cell By Pass Ngurah Rai……… 49

Tabel 4.4 Spesifikasi Battery LPJU solar cell By Pass Ngurah Rai…………… 49

Tabel 4.5 Spesifikasi Solar Change Control LPJU solar cell By Pass

Ngurah Rai………………………………………………………….. 50

Tabel 4.6 Spesifikasi Tiang LPJU solar cell By Pass Ngurah Rai…………….. 50

Tabel 4.7 Perbandingan Pemilihan Lampu…………………………………….. 54

Tabel 4.8 Hasil pengukuran output solar cell pada tanggal 22 Pebruari 2015.... 61

Tabel 4.9 Hasil pengukuran output solar cell pada tanggal 23 Pebruari 2015.... 63

Tabel 4.10 Hasil pengukuran output solar cell pada tanggal 24 Pebruari 2015... 65

Tabel 4.11 Hasil pengukuran output solar cell pada tanggal 25 Pebruari 2015... 67

Tabel 4.12 Hasil pengukuran output solar cell pada tanggal 26 Pebruari 2015... 68

Tabel 4.13 Hasil pengukuran output solar cell pada tanggal 27 Pebruari 2015... 70

Tabel 4.14 Hasil pengukuran output solar cell pada tanggal 28 Pebruari 2015.. 72

xviii

DAFTAR SINGKATAN DAN LAMBANG

a-Si : Amorphous silicon

AC : Alternating Current

A : Ampere

Ah : Ampere hour

BSN : Badan Standarisasi Nasional

CdS : Cadmium sulfide

CdTe : Cadmium telluride

CIGS : Copper indium di-seleiiide

CIS : Copper indium selenide

DC : Direct Current

DISHUBKOMINFO : Dinas Perhubungan Komunikasi dan Informatika

DOD : Depth Of Discharge

GaAs : Gallum arsenide

IP : Index of Protection

LED : Light Emiting Diode

LPJU : Lampu Penerangan Jalan Umum

LLF : Light Loss Factor

LVD : Low Voltage Discharge

MCB : Mini Circuit Breaker

PHB : Perangkat Hubung Bagi

PLN : Perusahan Listrik Negara

PUIL : Pedoman Umum Instalasi Listrik

PV : Photovoltaic

PWM : Pulse width modulation

SNI : Standar Nasional Indonesia

VLHR : Volume Lalu-lintas Harian Rata-rata

xix

𝜶 : ketinggian maksimum ketika matahari mencapai langit

𝜷 : sudut kemiringan dan panel surya

𝝓 : fluks cahaya

𝜼 : efikasi

𝜹 : sudut dari deklinasi matahari

𝜸 : sudut asimut

E : Jarak interval antar tiang lampu

H : Tinggi tiang lampu

i : sudut inklinasi pencahayaan/penerangan

I : Intensitas cahaya

l : Lebar badan jalan, termasuk median jika ada

L : luminasi

Lat : garis lintang (latitude)

N : Jumlah

M : biaya pemakaian tiap bulan

P : Daya

Q : Energi cahaya

R : titik jarak / luas

S1 : jarak tiang lampu ke tepi perkerasan

S2 : jarak dari tepi perkerasan ke titik penyinaran terjauh

t : waktu

U : Tarif biaya pemakaian tiap bulan

V : Volt

W : Watt

Wh : Watt hour

xx

DAFTAR LAMPIRAN

Lampiran 1. Lampu Penerangan Jalan Umum By Pass I GustiNgurah Rai yang

di dihentikan berlangganan daya PLN pada bulan Januari 2013... 99

Lampiran 1.1 Lampu Penerangan Jalan Umum By Pass I GustiNgurah Rai

yang di dihentikan berlangganan daya PLN pada bulan Januari

2013............................................................................................ 100

Lampiran 2. Spesifikasi Peralatan 1 Unit Lampu Penerangan Jalan Umum

Solar Cell di Jalan By Pass I Gusti Ngurah Rai………...…….. 101

Lampiran 2.1 Spesifikasi Lampu LED solar Green Vision family, Philip......... 102

Lampiran 2.2 Spesifikasi Panel Surya YL70P-17b Yingli Grenn holding

Monocrystaline........................................................................... 102

Lampiran 2.3 Spesifikasi Battery Battery LPJU solar cell By Pass Ngurah Rai. 102

Lampiran 2.4 Spesifikasi Solar Change Control, CIS20-1.1, Phocos China.... 103

Lampiran 2.5 Spesifikasi Tiang LPJU……………………………………....... 103

Lampiran 3. Sistem instalasi Lampu Penerangan Jalan Umum…………...... 104

Lampiran 3.1 Sistem instalasi Lampu Penerangan Jalan Umum…………...... 105

Lampiran 4. Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

Ngurah Rai ….……………………………………………....... 107

Lampiran 4.1 Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

Ngurah Rai (a)……………………………………………....... 107

Lampiran 4.2 Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

Ngurah Rai (b)……………………………………………....... 108

Lampiran 4.3 Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

Ngurah Rai (c)……………………………………………....... 109

Lampiran 4.4 Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

Ngurah Rai (d)……………………………………………....... 110

Lampiran 4.5 Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

xxi

Ngurah Rai (e)……………………………………………....... 111

Lampiran 4.6 Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

Ngurah Rai (f)……………………………………………....... 112

Lampiran 4.7 Denah Pemasangan LPJU Solar Cell di Jalan By Pass I Gusti

Ngurah Rai (g)……………………………………………....... 113

Lampiran 5. Dokumenasi Penelitian

Lampiran 5.1 Dokumenasi Pengukuran Output Tegangan Solar cell pada

Lampu Penerangan Jalan Umum Solar Cell di Jalan By Pass

I Gusti Ngurah Rai dalam kondisi cuaca cerah ……................ 115

Lampiran 5.1 Dokumenasi Pengukuran Output Arus Solar cell pada Lampu

Penerangan Jalan Umum Solar Cell di Jalan By Pass

I Gusti Ngurah Rai dalam kondisi cuaca cerah …….…...........