Fizikalna-svojstva-zgrade.pdf - Mlinarska

Post on 29-Jan-2023

1 views 0 download

Transcript of Fizikalna-svojstva-zgrade.pdf - Mlinarska

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta br.24A, tel/mob: 091/ 515-3810

www.lineamenta.hr, e-mail: studio@lineamenta.hr, OIB: 52601971360

Projektantski ured :

STUDIO LINEAMENTA d.o.o.

ČULINEČKA CESTA br.24A

10 040 ZAGREB

OIB: 52601971360

e-mail: studio@lineamenta.hr

Investitor :

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34,

10 000 ZAGREB,

OIB: 63702214100

Naziv građevine / zahvata u prostoru :

DOGRADNJA DVORANE ZA ERGONOMIJU

RADNOG PROSTORA U ZDRAVSTVU PRI

ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA U SVRHU USPOSTAVE REGIONALNOG CENTRA

KOMPETENTNOSTI U STRUKOVNOM

OBRAZOVANJU I OSPOSOBLJAVANJU, SEKTOR

ZDRAVSTVA

Lokacija građevine / zahvata u prostoru :

MLINARSKA CESTA br.34,

10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR

Zajednička oznaka projekta (ZOP) : Dokumentacijski broj projekta (TD) :

05-6/19 26-2019

Redni broj mape : Razina razrade :

MAPA 2 GLAVNI PROJEKT

Strukovna odrednica projekta :

ARHITEKTONSKI PROJEKT

Naziv projektiranog dijela građevine :

ARHITEKTONSKI PROJEKT

- PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE

Projektanti :

GLAVNI PROJEKTANT : PROJEKTANT :

Irena Gajšak Tonković, dipl.ing.arh., A-3034 Željka Veseljak, dipl.ing.arh., A-3245

e-potpis e-potpis

Mjesto i datum projekta : Odgovorna osoba u projektantskom uredu :

Zagreb, siječanj 2020. godine direktor:

Željka Veseljak,

dipl.ing.arh. e-potpis

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 2

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

SADRŽAJ DIJELA INVESTICIONO TEHNIČKE DOKUMENTACIJE :

OPĆI DIO

Popis mapa koje čine Glavni projekt Zajedničke oznake projekta (ZOP): 05-6/19 str. 3

Registracija poduzeća str. 5

Rješenje o imenovanju projektanta str. 9

Rješenje o upisu projektanta u Imenik ovlaštenih arhitekata str. 10

Izjava o usklađenosti str. 12

Projektni zadatak str. 16

Isprava o primijenjenim propisima zaštita od požara str. 17

TEHNIČKI DIO:

MAPA 2 / dio a : PRORAČUN RACIONALNE UPORABE ENERGIJE

I TOPLINSKE ZAŠTITE

MAPA 2 / dio b : PRIKAZ MJERA ZAŠTITE OD BUKE

Popis projektanata glavnog projekta zajedničke oznake projekta (ZOP): 05-6/19

Irena Gajšak Tonković, dipl.ing.arh.

Željka Veseljak, dipl.ing.arh.

Mladen Marijanović dipl.ing.građ.

Dragica Pašalić, ing.građ.

Renata Gajšak Žerjav, dipl.ing.el.

Darko Bailo, dipl.ing.stroj.

Zvonimir Šepac, dipl.ing.građ.

Tomislav Hrkać dip.ing.građ.

Popis projektanata koji su izradili elaborate koji su prethodili izradi ovog glavnog projekta:

Zvonimir Šepac, dipl.ing.građ.

Josip Radeljić, dipl.ing.građ.

Saša Gal mag.ing.aedif.

Irena Gajšak Tonković, dipl.ing.arh.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 3

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

POPIS MAPA GLAVNOG PROJEKTA

KOJI SAČINJAVAJU GLAVNI PROJEKT

ZA DOGRADNJU DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB

na k.č.br. 333 k.o. CENTAR

ZAJEDNIČKA OZNAKA PROJEKTA : 05-6/19

MAPA 1 ARHITEKTONSKI PROJEKT

TD: 05-6/19-A

ELAG d.o.o., Zagreb, Jure Kaštelana 17/b

Ovlašteni projektant: Irena Gajšak Tonković, dipl.ing.arh.

MAPA 2 ARHITEKTONSKI PROJEKT

- PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE

TD: 26-2019

STUDIO LINEAMENTA d.o.o., Zagreb, Čulinečka cesta br.24A

Ovlašteni projektant: Željka Veseljak, dipl.ing.arh.

MAPA 3 GRAĐEVINSKI PROJEKT KONSTRUKCIJE

TD: 08-02/19 K

PROING d.o.o., Zagreb, Šenoina 3

Ovlašteni projektant: Mladen Marijanović dipl.ing.građ.

MAPA 4 GRAĐEVINSKI PROJEKT – VODOVOD I ODVODNJA

TD: 28/19VO

VOKA – PROJEKT d.o.o., Zagreb, Črna voda 18 B

Ovlašteni projektant: Dragica Pašalić, ing.građ.

MAPA 5 ELEKTROTEHNIČKI PROJEKT – ELEKTRIČNE INSTALACIJE

TD: 05-6/19-E

ELAG d.o.o., Zagreb, Jure Kaštelana 17/b

Ovlašteni projektant: Renata Gajšak Žerjav, dipl.ing.el.

MAPA 6 ELEKTROTEHNIČKI PROJEKT - PROJEKT SUSTAVA DOJAVE POŽARA

TD: 05-6/19-V

ELAG d.o.o., Zagreb, Jure Kaštelana 17/b

Ovlašteni projektant: Renata Gajšak Žerjav, dipl.ing.el.

MAPA 7 STROJARSKI PROJEKT TERMOTEHNIČKIH INSTALACIJA

TD: 60-07-19

ABC ING d.o.o., Zagreb, Konjščinska 64

Ovlašteni projektant: Darko Bailo, dipl.ing.stroj.

MAPA 8 PROJEKT STABILNOSTI ISKOPA

TD: 02KW-0819

STM constructions d.o.o., Zagreb, Jaruščica 7a

Ovlašteni projektant: Zvonimir Šepac, dipl.ing.građ.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 4

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

MAPA 9 PROJEKT REKONSTRUKCIJE PROMETNICE I PARKIRALIŠTA

TD: 01/20

Firma BET-NADZOR d.o.o. Jurjevski hrast 11, Velika Gorica

Ovlašteni projektant: Tomislav Hrkać dip.ing.građ.

POPIS TEHNIČKIH PODLOGA

– ELABORATA TEMELJEM KOJIH JE IZRAĐEN GLAVNI PROJEKT

Izradi glavnog projekta, odnosno pojedinih projekata koje sadrži, prethodila je izrada sljedećih elaborata:

GEOMEHANIČKI ELABORAT

TD: 06FE-0619

STM constructions d.o.o., Zagreb, Jaruščica 7a

Izradio: Zvonimir Šepac, dipl.ing.građ.

ELABORAT ZAŠTITE OD POŽARA

TD: 393/19-ZOP

INSPEKTING d.o.o., Zagreb, Vučetićev prilaz 1

Izradio: Josip Radeljić, dipl.ing.građ.

ELABORAT ZAŠTITE NA RADU

TD: 08-02/19 ZNR

PROING d.o.o., Zagreb, Šenoina 3

Izradio: Saša Gal mag.ing.aedif.

KRAJOBRAZNI ELABORAT

TD: 05-6/19-K

ELAG d.o.o., Zagreb, Jure Kaštelana 17/b

Izradio: Irena Gajšak Tonković, dipl.ing.arh.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 5

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 6

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 7

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 8

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 9

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge

10 040 Zagreb - Dubrava, Čulinečka cesta br.24A, mob. 091/ 515-3810

www.lineamenta.hr, e-mail: studio@lineamenta.hr, OIB: 52601971360

Na temelju odredbi članka 51. "Zakona o gradnji" (N.N. br. 153/2013, 020/2017, 039/2019, 125/2019) "Studio

Lineamenta" d.o.o. za projektiranje nadzor i usluge iz Zagreba, donosi

RJEŠENJE O IMENOVANJU PROJEKTANTA

kojim se ovl.arh. Željka Veseljak, dipl.ing.arh.

imenuje za projektanta u projektnom zadatku :

Razina razrade: GLAVNI PROJEKT

Vrsta projekta: ARHITEKTONSKI PROJEKT

- PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE

Investitor : ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, OIB: 63702214100

MLINARSKA CESTA br.34, 10 000 ZAGREB

Građevina : DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U

ZDRAVSTVU PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA U SVRHU USPOSTAVE REGIONALNOG CENTRA KOMPETENTNOSTI U STRUKOVNOM

OBRAZOVANJU I OSPOSOBLJAVANJU, SEKTOR ZDRAVSTVA

Lokacija : MLINARSKA CESTA br.34, 10 000 ZAGREB

k.č.br. 333 k.o. CENTAR

Dokumentacijski broj projekta (TD): 26-2019

Zajednička oznaka projekta (ZOP): 05-6/19

Projektant Željka Veseljak, (OIB: 34328845156), dipl.ing.arh. nosi strukovni naziv "Ovlaštena arhitektica" i

upisana je u Imenik ovlaštenih arhitekata kod HRVATSKE KOMORE ARHITEKATA pod rednim brojem A-3245,

s danom upisa 09. 01. 2007. Klasa: UP/I-350-07/07-01/3245 Urbroj: 314-01-01-1.

Projektant Željka Veseljak, dipl.ing.arh. ispunjava uvjete iz Zakona o gradnji (N.N. br. 153/2013, 020/2017, 039/2019,

125/2019), Zakona o komori arhitekata i komorama inženjera u graditeljstvu i prostornom uređenju (NN 078/2015,

114/2018, 110/2019) i Zakona o poslovima i djelatnostima prostornog uređenja i gradnje (NN 078/2015, 118/2018,

110/2019), te odgovara da projekti koje izrađuje zadovoljavaju uvjete iz Zakona o gradnji (N.N. br. 153/2013,

020/2017, 039/2019, 125/2019) i posebnih zakona i drugih propisa.

U Zagrebu, siječanj 2020. godine.

DIREKTOR : Željka Veseljak, dipl.ing.arh.

"STUDIO LINEAMENTA"_____________________________________________________________________ d.o.o. za projektiranje, nadzor i usluge, 10 040 Zagreb - Dubrava, Čulinečka cesta br.24A

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 10

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 11

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 12

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Na temelju članaka 51. stavak 2 i članka 68. stavka 1 i 3. "Zakona o gradnji" (NN br. 153/2013, 020/2017, 039/2019,

125/2019) dajem ovu

IZJAVU O USKLAĐENOSTI broj I-26-2018.

Ja : Željka Veseljak, dipl. ing. arh.

zaposlena u "Studio Lineamenta" d.o.o. za projektiranje, nadzor i usluge

10 040 Zagreb - Dubrava, Čulinečka cesta br.24A, mob. 091/ 515-3810,

nosim strukovni naziv "Ovlaštena arhitektica" i upisana sam u Imenik ovlaštenih arhitekata kod HRVATSKE

KOMORE ARHITEKATA pod rednim brojem A-3245, s danom upisa 09. 01. 2007. Klasa: UP/I-350-07/07-01/3245

Urbroj: 314-01-01-1,

kao Projektant u projektnom zadatku :

Investitor : ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, OIB: 63702214100

MLINARSKA CESTA br.34, 10 000 ZAGREB

Građevina : DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U

ZDRAVSTVU PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA U SVRHU USPOSTAVE REGIONALNOG CENTRA KOMPETENTNOSTI U STRUKOVNOM

OBRAZOVANJU I OSPOSOBLJAVANJU, SEKTOR ZDRAVSTVA

Lokacija : MLINARSKA CESTA br.34, 10 000 ZAGREB

k.č.br. 333 k.o. CENTAR

Razina razrade: GLAVNI PROJEKT

Vrsta projekta: ARHITEKTONSKI PROJEKT

- PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE

Dokumentacijski broj projekta (TD): 26-2019

Zajednička oznaka projekta (ZOP): 05-6/19

izjavljujem :

da je Mapa 2: Arhitektonski projekt – Proračun fizikalnih svojstava zgrade izrađen (prema Mapi 1: Arhitektonskom

projektu) u skladu sa važećom prostorno planskom dokumentacijom:

- Odlukom o donošenju Prostornog plana Grada Zagreba – Službeni Glasnik Grada Zagreba, br. 03/2018 – pročišćeni

tekst

- Odlukom o donošenju Generalnog urbanističkog plana Grada Zagreba – Službeni Glasnik Grada Zagreba, br. 016/2007,

008/2009, 007/2013, 009/2016, 012/2016 – pročišćeni tekst.

u dijelu koji se odnosi na ovu mapu (Mapa 2).

Ovaj projekt temeljem članka 51. stavka 2. Zakona o gradnji (NN br. 153/2013, 020/2017, 039/2019, 125/2019)

ispunjava bitne zahtjeve za građevinu, a usklađen je s odredbama članka 68. Zakona o gradnji (NN br. 153/2013,

020/2017, 039/2019, 125/2019), posebnim uvjetima i posebnim uvjetima priključenja, te posebnim Zakonima,

Tehničkim propisima i Pravilnicima navedenima u popisu (sve u dijelu koji se odnose na ovu mapu):

Arhitektonska djelatnost 1. Zakon o komori arhitekata i komorama inženjera u graditeljstvu i prostornom uređenju (NN 078/2015, 114/2018,

110/2019)

2. Zakon o poslovima i djelatnostima prostornog uređenja i gradnje (NN 078/2015, 118/2018, 110/2019)

3. Pravilnik o stručnom ispitu osoba koje obavljaju poslove graditeljstva i prostornoga uređenja (NN 129/2015)

4. Zakon o reguliranim profesijama i priznavanju inozemnih stručnih kvalifikacija (NN 082/2015)

5. Zakon o općem upravnom postupku (NN 047/2009)

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 13

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

6. Zakon o autorskom pravu i srodnim pravima (NN 167/2003, 079/2007, 080/2011 141/2013, 127/2014, 062/2017)

7. Zakon o obveznim odnosima (NN 035/2005, 041/2008, 078/2015)

8. Statut Hrvatske komore arhitekata (NN 140/2015, 043/2017, 085/2019)

9. Kodeks strukovne etike članova Hrvatske komore arhitekata (NN 043/2016)

10. Zakon o upravnim pristojbama (NN 115/2016)

11. Uredba o tarifi upravnih pristojbi (NN 008/2017, 037/2017, 129/2017, 018/2019, 097/2019)

12. Zakon o obavljanju geodetske djelatnosti (NN 025/2018)

Gradnja 13. Zakon o prostornom uređenju (NN 153/2013, 065/2017, 114/2018, 039/2019, 098/2019)

14. Zakon o gradnji (NN 153/2013, 020/2017, 039/2019, 125/2019)

15. Uredba o određivanju zahvata u prostoru i građevina za koje Ministarstvo zaštite okoliša, prostornog uređenja i

graditeljstva izdaje lokacijsku i/ili građevinsku dozvolu (NN 116/2007, 056/2011)

16. Zakon o preuzimanju prije važećih propisa (NN 053/1991)

17. Zakon o postupanju s nezakonito izgrađenim zgradama (NN 086/2012, 143/2013, 065/2017, 014/2019)

18. Pravilnik o jednostavnim i drugim građevinama i radovima (NN 112/2017, 034/2018, 036/2019, 098/2019)

19. Pravilnik o osiguranju pristupačnosti građevina osobama s invaliditetom i smanjene pokretljivosti (NN 078/2013)

20. Pravilnik o načinu izračuna građevinske (bruto) površine zgrade (NN 093/2017)

21. Pravilnik o zahvatima u prostoru koji se ne smatraju građenjem, a za koje se izdaje lokacijska dozvola (NN 105/2017,

108/2017)

22. Pravilnik o obveznom sadržaju idejnog projekta (NN 118/2019)

23. Pravilnik o obveznom sadržaju i opremanju projekata građevina (NN 118/2019)

24. Naputak o izradi nacrta akata u postupku izdavanja akata na temelju Zakona o prostornom uređenju i Zakona o gradnji te

provedbi tih postupaka elektroničkim putem (NN 056/2014)

25. Pravilnik o potrebnim znanjima iz područja upravljanja projektima (NN 085/2015)

26. Pravilnik o nostrifikaciji projekata (NN 098/1999, 029/2003, 020/2017)

27. Pravilnik o kontroli projekata (NN 032/2014)

28. Pravilnik o održavanju građevina (NN 122/2014, 098/2019)

Građevinska inspekcija, građenje i tehnički pregled 29. Zakon o građevinskoj inspekciji (NN 153/2013)

30. Pravilnik o načinu zatvaranja i označavanja zatvorenog gradilišta (NN 116/2019)

31. Pravilnik o načinu pečaćenja oruđa, strojeva i dr. sredstava za rad izvođača na gradilištu (NN 047/2012)

32. Pravilnik o načinu obavljanja inspekcijskog nadzora građevne inspekcije (NN 009/2000, 099/2002)

33. Pravilnik o službenoj iskaznici i znački građevinskog inspektora (NN 042/2014)

34. Pravilnik o materijalno-tehničkim uvjetima za rad građevnih inspektora (NN 116/2019)

35. Pravilnik o tehničkom pregledu građevine (NN 046/2018, 098/2019)

36. Pravilnik o načinu provedbe stručnog nadzora građenja, obrascu, uvjetima i načinu vođenja građevinskog dnevnika te o

sadržaju završnog izvješća nadzornog inženjera (NN 111/2014, 107/2015, 020/2017, 098/2019, 121/2019)

37. Pravilnik o suglasnosti za započinjanje obavljanja djelatnosti građenja (NN 043/2009)

38. Pravilnik o sadržaju i izgledu ploče kojom se označava gradilište (NN 043/2014)

39. Pravilnik o sadržaju pisane Izjave izvođača o izvedenim radovima i uvjetima održavanja građevine (NN 043/2014)

40. Klasifikacija vrsta građevina-KGV i metodološke upute za mjesečni i tromjesečni izvještaj građevinarstva (GRAĐ-

21/M7OBRT, GRAĐ-2173M) (NN 11/98)

41. Pravilnik o manje složenim radovima (NN 014/2020)

Komunalno gospodarstvo 42. Zakon o komunalnom gospodarstvu (NN 068/2018, 110/2018 – Odluka Ustavnog suda RH)

43. Podatak o prosječnim troškovima građenja kubnog metra (m3) građevine u Republici Hrvatskoj (NN 098/2018)

44. Pravilniku o načinu utvrđivanja obujma i površine građevina u svrhu obračuna komunalnog doprinosa (NN 015/2019)

45. Podatak o etalonskoj cijeni građenja (NN 067/2019)

Tehnički propisi

Nosiva konstrukcija 46. Tehnički propis za građevinske konstrukcije (NN 017/2017)

47. Tehnički propis za staklene konstrukcije (NN 053/2017)

Zgradarstvo 48. Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018,

086/2018)

49. Algoritam za proračun potrebne energije za grijanje i hlađenje prostora zgrade prema HRN EN ISO 13790 (MGIPU,

Zagreb, svibanj 2017.)

50. Metodologija provođenja energetskog pregleda zgrada (MGIPU, Zagreb, kolovoz 2017., u obaveznoj primijeni od 30. rujna

2017. godine)

51. Tehnički propis za prozore i vrata (NN 069/2006)

52. Odluka o popisu normi bitnih za primjenu Tehničkog propisa za prozore i vrata www.mzopu.hr

53. Zakon o energetskoj učinkovitosti (NN 127/2014, 116/2018)

54. Zakon o obnovljivim izvorima energije i visokoučinkovitoj kogeneraciji (NN 100/2015)

55. Pravilnik o energetskom pregledu zgrade i energetskom certificiranju (NN 088/2017)

56. Pravilnik o osobama ovlaštenim za energetsko certificiranje, energetski pregled zgrade i redoviti pregled sustava grijanja i

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 14

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

sustava hlađenja ili klimatizacije u zgradi (NN 073/2015)

57. Pravilnik o kontroli energetskog certifikata zgrade i izvješća o redovitom pregledu sustava grijanja i sustava hlađenja ili

klimatizacije u zgradi (NN 073/2015)

58. Pravilnik o sustavu obveze energetske učinkovitosti (NN 041/2019)

Strojarske instalacije 59. Tehnički propis o sustavima ventilacije, djelomične klimatizacije i klimatizacije zgrada (NN 003/2007)

60. Tehnički propis za dimnjake u građevinama (NN 003/2007)

61. Tehnički propis o sustavima grijanja i hlađenja zgrada (NN 110/2008)

62. Prozračivanje u skladu s HRN U.02.201 i HRN U.02.202 (NN 053/1991, 055/1996)

Priznata tehnička pravila 63. Pravilnik o tehničkim normativima za projektiranje i izvođenje završnih radova u građevinarstvu (Sl. list SFRJ 21/1990)

64. Pravilnik o tehničkim mjerama i uvjetima za ugljikovodične hidroizolacije krovova i terasa (Sl. list SFRJ 26/1969)

65. Naredba o obaveznom atestiranju ploča iverica za opću uporabu i građevinarstvo (Sl.list SFRJ 61/1983)

66. HRN U.F2.010/78 - Tehnički uvjeti za izvođenje fasaderskih radova-

67. HRN U.F2.011/77 - Tehnički uvjeti za izvođenje keramičarskih radova.

68. HRN U.F2.012/78 - Tehnički uvjeti za izvođenje ličilačkih radova.

69. HRN U.F2.016/77 - Tehnički uvjeti za izvođenje parketarskih radova.

70. HRN U.FS.017/78 - . Tehnički uvjeti za izvođenje radova pri polaganju podnih podloga.

71. HRN U.F2.024/80 - . Tehnički uvjeti izvođenja izolacijskih radova na ravnim krovovima.

72. HRN U.F3.050/78 - Tehnički uvjeti za izvođenje teracerskih radova.

73. HRN U.F7.010/68 - Prirodni kamen. Tehnički uvjeti za oblaganje kamenim pločama.

Građevni proizvodi 74. Zakon o građevnim proizvodima (NN 076/2013, 030/2014, 130/2017, 039/2019)

75. Zakon o tehničkim zahtjevima za proizvode i ocjenjivanju sukladnosti (NN 080/2013, 014/2014)

76. Pravilnik o tijelima, dokumentaciji i postupcima tržišta građevnih proizvoda (NN 118/2019)

77. Pravilnik o ocjenjivanju sukladnosti, ispravama o sukladnosti i označavanju građevnih proizvoda (NN 103/2008, 147/2009,

087/2010, 129/2011) – izvan snage osim odredbi članka 4. stavaka 4. i 5., članka 16. i Tablice 1.

78. Pravilnik o nadzoru građevnih proizvoda (NN 113/2008)

79. Tehnički propis o građevnim proizvodima (NN 035/2018, 104/2019)

80. Uredba o usklađivanju područja građevnih proizvoda s Uredbom (EU) br. 305/2011 u prijelaznom razdoblju (NN

046/2013)

81. Tehnički propis kojim se utvrđuju tehničke specifikacije za građevne proizvode u usklađenom području (NN 004/2015,

024/2015, 093/2015, 133/2015, 036/2016, 058/2016, 104/2016, 028/2017, 088/2017, 029/2018, 043/2019)

Opća sigurnost proizvoda 82. Zakon o općoj sigurnosti proizvoda (NN 030/2009, 139/2010, 014/2014)

83. Pravilnik o obavješćivanju o proizvodu koji je opasan za potrošače (NN 055/2010)

84. Popis usklađenih hrvatskih normi u području opće sigurnosti proizvoda (NN 013/2016)

Normizacija, akreditacija mjeriteljstvo 85. Zakon o normizaciji (NN 080/2013)

86. Zakon o akreditaciji (NN 158/2003, 075/2009, 056/2013)

87. Zakon o mjeriteljstvu (NN 74/2014)

88. Pravilnik o mjernim jedinicama (NN 088/2015, 016/2020)

89. Pravilnik o tehničkim i mjeriteljskim zahtjevima koji se odnose na mjerila (NN 085/2013)

Zaštita okoliša i prirode i kulturnih dobara 90. Zakon o zaštiti okoliša (NN 080/2013, 078/2015, 012/2018, 118/2018)

91. Uredba o procjeni utjecaja zahvata na okoliš (NN 064/2008, 067/2009)

92. Zakon o zaštiti zraka (NN 127/2019)

93. Pravilnik o gospodarenju građevnim otpadom (NN 038/2008)

94. Pravilnik o građevnom otpadu i otpadu koji sadrži azbest (NN 069/2016)

95. Zakon o održivom gospodarenju otpadom (NN 094/2013, 173/2017, 014/2019, 098/2019)

96. Zakon o zaštiti prirode (NN 080/2013, 015/2018, 014/2019, 127/2019)

97. Zakon o zaštiti pučanstva od zaraznih bolesti (NN 079/2007, 113/2008, 043/2009)

98. Zakon o zaštita i očuvanju kulturnih dobara (NN 069/1999, 151/2003, 157/2003, 087/2009, 088/2010, 061/2011, 025/2012,

136/2012, 157/2013, 152/2014, 098/2015, 044/2017)

Zaštita na radu 99. Zakon o zaštiti na radu (NN 071/2014, 118/2014-ispravak, 154/2014-uredba Vlade RH)

100. Zakon o Državnom inspektoratu (NN 116/2008, 123/2008, 049/2011)

101. Pravilnik o zaštiti na radu za mjesta rada (NN 029/2013)

102. Pravilnik o vrsti objekata namijenjenih za rad kod kojih inspekcija rada sudjeluje u postupku izdavanja građevnih dozvola i

u tehničkim pregledima izgrađenih objekata (NN 048/1997)

103. Pravilnik o zaštiti na radu u građevinarstvu (Sl. list SFRJ 42/68, 45/68-ispravak)

104. Pravilnik o zaštiti na radu na privremenim gradilištima (NN 048/2018)

Zaštita od buke 105. Zakon o zaštiti od buke (NN 030/2009, 055/2013, 153/2013, 041/2016, 114/2018)

106. Pravilnik o najvišim dopuštenim razinama buke u sredini u kojoj ljudi rade i borave (NN 145/2004)

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 15

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

107. Pravilnik o zaštiti radnika od izloženosti buci na radu ( NN 046/2008)

108. Pravilnik o djelatnostima za koje je potrebno utvrditi provedbu mjera za zaštitu od buke (NN 091/2007)

109. Pravilnik o mjerama zaštite od buke izvora na otvorenom prostoru (NN 156/2008)

110. HRN U.J6.001/82 - akustika u građevinarstvu: Termini i definicije

111. HRN U.J6.151/82 - akustika u građevinarstvu: Standardne vrijednosti za ocjenu zvučne izolacije

112. HRN U.J6.201/89 - akustika u građevinarstvu: Tehnički uvjeti za projektiranje i građenje zgrada

113. HRN U.J6.153/89 - akustika u građevinarstvu: Metode izračunavanja zvučne izolacije jednim brojem

114. HRN U.J6.205/90 - akustika u građevinarstvu: Akustičko zoniranje prostora

115. HRN U.J6.216/82 - akustika u građevinarstvu: Akustička kvaliteta malih i srednje velikih prostorija

116. HRN EN ISO 16283-1:2014 (zvučna izolacija)

Zaštita od požara 117. Zakon o zaštiti od požara (NN 092/2010)

118. Pravilnik o razvrstavanju građevina, građevinskih dijelova i prostora u kategoriji ugroženosti o požara (NN 062/1994,

032/1997)

119. Pravilnik o razvrstavanju građevina u skupine po zahtjevnosti mjera zaštite od požara (NN 056/2012, 061/2012-ispravak)

120. Pravilnik o sadržaju elaborata zaštite od požara (NN 051/2012)

121. Pravilnik o uvjetima za vatrogasne pristupe (NN 035/1994, 055/1994-ispravak, 142/2003)

122. Pravilnik o vatrogasnim aparatima (NN 101/2011, 074/2013)

123. Pravilnik o hidrantskoj mreži za gašenje požara (NN 008/2006)

124. Pravilnik o sustavima za dojavu požara (NN 056/1999)

125. Pravilnik o ovlaštenjima za izradu elaborata zaštite od požara (NN 141/2011)

126. Pravilnik o provjeri tehničkih rješenja iz zaštite od požara predviđenih u glavnom projektu (NN 088/2011)

127. Pravilnik o revidentima iz zaštite od požara (NN 141/2011)

128. Pravilnik o mjerama zaštite od požara kod građenja (NN 141/2011)

129. Pravilnik o otpornosti na požar i drugim zahtjevima koje građevine moraju zadovoljiti u slučaju požara (NN 029/2013,

087/2015)

130. Pravilnik o tehničkim normativima za zaštitu visokih objekata od požara (Sl. list SFRJ 7/84)

131. Pravilnik o zahvatima u prostoru u kojima tijelo nadležno za zaštitu od požara ne sudjeluje u postupku izdavanja rješenja o

uvjetima građenja, odnosno lokacijske dozvole (NN 115/2011)

Vodno gospodarstvo 132. Zakon o vodama (NN 153/2009, 130/2011, 056/2013, 014/2014, 046/2018)

133. Uredba o visini vodnog doprinosa (NN 078/2010, 076/2011, 019/2012, 151/2013, 083/2015)

134. Pravilnik o izdavanju vodopravnih akata (NN 078/2010, 079/2013, 009/2014)

135. Pravilnik o obračunu i naplati vodnog doprinosa (NN 107/2014)

136. Pravilnik o obračunavanju i plaćanju naknade za zaštitu voda (NN 083/2010)

137. Pravilnik o obračunu i naplati naknade za korištenje voda (NN 084/2010, 146/2012)

138. Pravilnik o obračunu i naplati naknade za uređenje voda (NN 083/2010)

139. Zakon o vodi za ljudsku potrošnju (NN 056/2013, 064/2015)

140. Pravilnik o posebnim uvjetima za obavljanje djelatnosti uzimanja uzoraka i ispitivanja voda (NN 020/2011)

141. Pravilnik o zdravstvenoj ispravnosti vode za piće (NN 047/2008)

Sanitarno – tehnički uvjeti 142. Zakon o sanitarnoj inspekciji (NN 113/2008, 088/2010)

143. Pravilnik o sadržaju i načinu davanja potvrde o usklađenosti glavnog projekta sa sanitarno-tehničkim uvjetima gradnje i

vrstama građevina koje podliježu sanitarnom nadzoru (NN 093/1999)

144. Pravilnik o građevinama koje podliježu sanitarnom nadzoru te načinu obavljanja sanitarnog nadzora tijekom njihove

gradnje (NN 048/2000, 042/2008)

U Zagrebu, siječanj 2020. godine.

PROJEKTANT :

Željka Veseljak, dipl.ing.arh.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 16

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

PROJEKTNI ZADATAK

za DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U

ZDRAVSTVU PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA

U SVRHU USPOSTAVE REGIONALNOG CENTRA KOMPETENTNOSTI U

STRUKOVNOM OBRAZOVANJU I OSPOSOBLJAVANJU, SEKTOR ZDRAVSTVA

Na zahtjev Investitora

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA,

MLINARSKA CESTA br.34,

10 000 ZAGREB,

OIB: 63702214100

treba izraditi:

ARHITEKTONSKI PROJEKT - PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE

koji se sastoji od

Proračuna racionalne uporabe energije i toplinske zaštite

i

Prikaza mjera zaštite od buke

za dobivanje dozvole za DOGRADNJU DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA, na lokaciji u Mlinarskoj cesti br.34, Zagreb, na k.č.br. 333

k.o. CENTAR.

Gore navedenim dijelovima Arhitektonskog projekta – Proračuna fizikalnih svojstava zgrade potrebno je dokazati

ispunjavanje temeljnih zahtjeva za građevinu koja je predmet ovog zahvata u vezi temeljnog zahtjeva

- higijene, zdravlja i okoliša: u području koje se odnosi na uvjet da nema prisutnost vlage u dijelovima

građevine ili na površini unutar građevine

- zaštite od buke

- gospodarenje energijom i očuvanje topline: u području koje se odnosi na uvjet racionalne uporabe energije i

toplinske zaštite zgrade.

U Zagrebu, siječanj 2020. godine.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 17

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge

10 040 Zagreb - Dubrava, Čulinečka cesta br.24A, mob. 091/ 515-3810

www.lineamenta.hr, e-mail: studio@lineamenta.hr, OIB: 52601971360

Na temelju čl. 25 "Zakona o zaštiti od požara" (N.N. br. 092/2010) daje se ova

ISPRAVA PROJEKTANTA O PRIMIJENJENIM PROPISIMA

ZAŠTITE OD POŽARA broj : 26-2018

Investitor : ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, OIB: 63702214100

MLINARSKA CESTA br.34, 10 000 ZAGREB

Građevina : DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U

ZDRAVSTVU PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA U SVRHU USPOSTAVE REGIONALNOG CENTRA KOMPETENTNOSTI U STRUKOVNOM

OBRAZOVANJU I OSPOSOBLJAVANJU, SEKTOR ZDRAVSTVA

Lokacija : MLINARSKA CESTA br.34, 10 000 ZAGREB

k.č.br. 333 k.o. CENTAR

Razina razrade: GLAVNI PROJEKT

Vrsta projekta: ARHITEKTONSKI PROJEKT

- PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE

Dokumentacijski broj projekta (TD): 26-2019

Zajednička oznaka projekta (ZOP): 05-6/19

kojom se potvrđuje sljedeće:

- Izvršena je provjera ovog dijela tehničke dokumentacije za građevinu koja je predmet ovog zahvata

(Arhitektonski projekt - Proračun fizikalnih svojstava zgrade)

- Mjere zaštite od požara i tehnička rješenja primijenjena u ovoj tehničkoj dokumentaciji udovoljavaju Zakonu

o zaštiti od požara (NN 092/2010), posebnim uvjetima uređenja prostora te tehničkim propisima i normama.

U Zagrebu, siječanj 2020. godine.

PROJEKTANT :

Željka Veseljak, dipl.ing.arh.

DIREKTOR : Željka Veseljak, dipl.ing.arh.

"STUDIO LINEAMENTA"_____________________________________________________________________ d.o.o. za projektiranje, nadzor i usluge, 10 040 Zagreb - Dubrava, Čulinečka cesta br.24A

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta br.24A, tel/mob: 091/ 515-3810 www.lineamenta.hr, e-mail: studio@lineamenta.hr, OIB: 52601971360

Projektantski ured : STUDIO LINEAMENTA d.o.o. ČULINEČKA CESTA br.24A 10 040 ZAGREB OIB: 52601971360 e-mail: studio@lineamenta.hr Investitor : ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB, OIB: 63702214100 Naziv građevine / zahvata u prostoru : DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA U SVRHU USPOSTAVE REGIONALNOG CENTRA KOMPETENTNOSTI U STRUKOVNOM OBRAZOVANJU I OSPOSOBLJAVANJU, SEKTOR ZDRAVSTVA Lokacija građevine / zahvata u prostoru : MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR Zajednička oznaka projekta (ZOP) : Dokumentacijski broj projekta (TD) : 05-6/19 26-2019

Redni broj mape : Razina razrade : MAPA 2 / dio a GLAVNI PROJEKT

Strukovna odrednica projekta : ARHITEKTONSKI PROJEKT

Naziv projektiranog dijela građevine :

PRORAČUN RACIONALNE UPORABE ENERGIJE I TOPLINSKE ZAŠTITE Projektanti : PROJEKTANT : SURADNIK

Željka Veseljak, dipl.ing.arh., A-3245 Neno Veseljak, CAD specijalist

Mjesto i datum projekta : Odgovorna osoba u projektantskom uredu : Zagreb, siječanj 2020. godine direktor:

Željka Veseljak, dipl.ing.arh.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 2

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Proračun racionalne uporabe energije i toplinske zaštite izrađen je na temelju slijedećih važećih zakona, normi i pravilnika: - Zakon o prostornom uređenju (NN 153/2013, 065/2017, 114/2018, 039/2019, 098/2019) - Zakon o gradnji (NN 153/2013, 020/2017, 039/2019, 125/2019) - Zakon o normizaciji (NN 080/2013) - Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018,

073/2018, 086/2018) - Tehnički propis za prozore i vrata (NN 069/2006) - Algoritam za proračun potrebne energije za grijanje i hlađenje prostora zgrade prema HRN EN ISO 13790

(MGIPU, Zagreb, svibanj 2017.) - Metodologija provođenja energetskog pregleda zgrada (MGIPU, Zagreb, kolovoz 2017., u obaveznoj primjeni

od 30. rujna 2017. godine) - Zakon o energetskoj učinkovitosti (NN 127/2014, 116/2018) - Tehnički propis o sustavima grijanja i hlađenja zgrada (NN 110/2008) - Tehnički propis o sustavima ventilacije, djelomične klimatizacije i klimatizacije zgrada (NN 003/2007) - Zakon o građevnim proizvodima (NN 076/2013, 030/2014, 130/2017, 039/2019) - Zakon o tehničkim zahtjevima za proizvode i ocjenjivanju sukladnosti (NN 080/2013, 014/2014) - Tehnički propis o građevnim proizvodima (NN 035/2018, 104/2019) - Pravilnik o nadzoru građevnih proizvoda (NN 113/2008) - Pravilnik o energetskom pregledu zgrade i energetskom certificiranju (NN 088/2017) - Tehnički propis za dimnjake u građevinama (NN 003/2007) - Pravilnik o tijelima, dokumentaciji i postupcima tržišta građevnih proizvoda (NN 118/2019) - Pravilnik o ocjenjivanju sukladnosti, ispravama o sukladnosti i označavanju građevnih proizvoda (NN

103/2008, 147/2009, 087/2010, 129/2011) – izvan snage osim odredbi članka 4. stavaka 4. i 5., članka 16. i Tablice 1.

- Pravilnik o tehničkim normativima za projektiranje i izvođenje završnih radova u građevinarstvu (Sl. list SFRJ 21/1990)

- Pravilnik o održavanju građevina (NN 122/2014, 098/2019) Napomena izvođaču: Proračun racionalne uporabe energije i toplinske zaštite izrađen je na osnovu navedenih zakona, tehničkih propisa i pravilnika kojih se treba pridržavati i izvođač pri izvedbi. U slučaju promjene vrste materijala i koncepcije konstrukcija iz ovog dijela Arhitektonskog projekta, treba tražiti suglasnost projektanta, a novi materijal i nova koncepcija konstrukcije ne smije imati lošije karakteristike od karakteristika utvrđenih ovim dijelom glavnog projekta, niti narušiti postignuti nivo toplinske zaštite i uštede energije. Za sve ugrađene materijale treba pribaviti ateste od u Hrvatskoj mjerodavnih institucija kojima se potvrđuju svojstva čijim se vrijednostima koristilo u ovom proračunu. Materijali se trebaju ugrađivati u klimatskim uvjetima koji su odgovarajući toj vrsti materijala, a izvedba-ugradba se treba povjeriti ekipama stručnim za odgovarajuću vrstu radova.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 3

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Hrvatske norme: HRN EN 410:2011 Staklo u graditeljstvu -- Određivanje svjetlosnih i sunčanih značajka ostakljenja (EN 410:2011) HRN EN 673:2011 Staklo u graditeljstvu -- Određivanje koeficijenta prolaska topline (U vrijednost) -- Proračunska metoda (EN 673:2011) HRN EN ISO 6946:2008 Građevni dijelovi i građevni dijelovi zgrade -- Toplinski otpor i koeficijent prolaska topline -- Metoda proračuna (ISO 6946:2007; EN ISO 6946:2007) HRN ISO 9836:2011 Standardi za svojstva zgrada -- Definiranje i proračun površina i prostora (ISO 9836:2011) HRN EN ISO 10077-1:2008 Toplinska svojstva prozora, vrata i zaslona -- Proračun koeficijenta prolaska topline -- 1. dio: Općenito (ISO 10077-1:2006; EN ISO 10077-1:2006) HRN EN ISO 10077-1:2008/Ispr.1:2010 Toplinska svojstva prozora, vrata i zaslona -- Proračun koeficijenta prolaska topline -- 1. dio: Općenito (ISO 10077-1:2006/Cor 1:2009; EN ISO 10077-1:2006/AC:2009) HRN EN ISO 10211:2008 Toplinski mostovi u zgradarstvu -- Toplinski tokovi i površinske temperature -- Detaljni proračuni (ISO 10211:2007; EN ISO 10211:2007) HRN EN ISO 10456:2008 Građevni materijali i proizvodi -- Svojstva s obzirom na toplinu i vlagu -- Tablične projektne vrijednosti i postupci određivanja nazivnih i projektnih toplinskih vrijednosti (ISO 10456:2007; EN ISO 10456:2007) HRN EN 12464-1:2012 Svjetlo i rasvjeta -- Rasvjeta radnih mjesta -- 1. dio: Unutrašnji radni prostori (EN 12464-1:2011) HRN EN 12524:2002 Građevni materijali i proizvodi -- Svojstva s obzirom na toplinu i vlagu -- Tablice projektnih vrijednosti (EN 12524:2000) HRN EN 12831:2004 Sustavi grijanja u građevinama -- Postupak proračuna normiranoga toplinskog opterećenja (EN 12831:2003) HRN EN ISO 13370:2008 Toplinske značajke zgrada -- Prijenos topline preko tla -- Metode proračuna (ISO 13370:2007; EN ISO 13370:2007) HRN EN 13779:2008 Ventilacija u nestambenim zgradama -- Zahtjevi za sustave ventilacije i klimatizacije (EN 13779:2007) HRN EN ISO 13788:2002 Značajke građevnih dijelova i građevnih dijelova zgrada s obzirom na toplinu i vlagu -- Temperatura unutarnje površine kojom se izbjegava kritična vlažnost površine i unutarnja kondenzacija -- Metode proračuna (ISO 13788:2001; EN ISO 13788:2001) HRN EN ISO 13789:2008 Toplinske značajke zgrada -- Koeficijenti prijelaza topline transmisijom i ventilacijom -- Metoda proračuna (ISO 13789:2007; EN ISO 13789:2007) HRN EN ISO 13790:2008 Energetska svojstva zgrada -- Proračun potrebne energije za grijanje i hlađenje prostora (EN ISO 13790:2008) HRN EN ISO 14683:2008 Toplinski mostovi u zgradarstvu -- Linearni koeficijent prolaska topline -- Pojednostavnjene metode i zadane utvrđene vrijednosti (ISO 14683:2007; EN ISO 14683:2007) HRN EN 15193:2008 Energijska svojstva zgrade -- Energijski zahtjevi za rasvjetu (EN 15193:2007) HRN EN 15193:2008/Ispr.1:2011 Energijska svojstva zgrade -- Energijski zahtjevi za rasvjetu (EN 15193:2007/AC:2010) HRN EN 15232:2012 Energijske značajke zgrada -- Utjecaj automatizacije zgrada, nadzor i upravljanje zgradama (EN 15232:2012) HRN EN 15251:2008 Ulazni mikroklimatski parametri za projektiranje i ocjenjivanje energijskih značajka zgrada koji se odnose na kvalitetu zraka, toplinsku lagodnost, osvjetljenje i akustiku (EN 15251:2007)

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 4

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

SADRŽAJ

A) TEHNIČKI OPIS str. 5 1. OPĆENITO str. 5 1.1. Lokacija, kategorizacija, prostorna dispozicija str. 5 1.2. Konstrukcija str. 8 1.3. Koncepcija toplinske zaštite str. 10 1.4. Strojarske instalacije - grijanje, ventilacija, klimatizacija str. 11 2. SLOJEVI OBODNIH KONSTRUKCIJA str. 13 B) PROGRAM KONTROLE I OSIGURANJA KVALITETE str. 35 U ODNOSU NA GRAĐEVNE PROIZVODE KOJI SE UGRAĐUJU U ZGRADU U

SVRHU UŠTEDE TOPLINSKE ENERGIJE I TOPLINSKE ZAŠTITE

1. UVOD str. 35 2. GRAĐEVNI PROIZVODI str. 37 3. POPIS HRVATSKIH NORMI I DRUGIH TEHNIČKIH SPECIFIKACIJA KOJE

UPUĆUJU NA ZAHTJEVE KOJE, U SVEZI S TOPLINSKOM ZAŠTITOM, TREBAJU ISPUNITI TOPLINSKO-IZOLACIJSKI GRAĐEVNI PROIZVODI ZA ZGRADE

str. 42

4. NORME ZA ISPITIVANJE NA KOJE UPUĆUJE PROPIS str. 43 5. TEHNIČKA SVOJSTVA I DRUGI ZAHTJEVI ZA GRAĐEVNE PROIZVODE str. 43 6. DOPUŠTENA ZRAKOPROPUSNOST OVOJNICE ZGRADE, VENTILIRANJE

PROSTORA ZGRADE str. 44

7. PROZORI I VRATA (prema Tehničkom propisu za prozore i vrata (NN 069/2006)) str. 45 8. UVJETI ZA ODRŽAVANJE GRAĐEVINE U ODNOSU NA RACIONALNU

UPORABU ENERGIJE I TOPLINSKU ZAŠTITU str. 46

C) PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE GLEDE RACIONALNE

UPORABE ENERGIJE I TOPLINSKE ZAŠTITE str. 48

(PRILOG) Proračun je napravljen s računalnim programom EnCert-HR2; str. 1 - str. 51 D) NACRTI str. 49 (PRILOG) list. 1 - list. 5 E) KATALOG DOBRO RJEŠENIH TOPLINSKIH MOSTOVA NA ZGRADAMA -

prilog D Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018)

str. 50

(PRILOG) list. 1 - 10

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 5

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

A) TEHNIČKI OPIS 1. OPĆENITO 1.1. Lokacija, kategorizacija, prostorna dispozicija Na parceli koja se nalazi u Zagrebu, Mlinarska ulica br.34, na k.č.br. 333 k.o. Centar, se predviđa DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU (PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA). Ovim projektom je predviđena izgradnja dvorane, prostorija za edukaciju i popratnih prostorija kao dogradnja odnosno dio Škole za medicinske sestre Mlinarska, a namjena cijele dogradnje je zgrada za obrazovanje sa svim pratećim zatvorenim i otvorenim prostorima. Etažnost zgrade je: prizemlje+kat. Zgrada se dograđuje sa istočne strane školskog kompleksa. Teren na parceli je u padu po zapada prema istoku, prema Medvedgradskoj ulici. Sukladno važećoj prostorno planskoj dokumentaciji (Generalnom urbanističkom planu Grada Zagreba), predmetna građevina nalazi se unutar zone javne i društvene namjene – školska namjena (D5). Predmetna parcela omeđena je Mlinarskom ulicom na zapadu, te Medvedgradskom ulicom na istoku. U postojećoj građevini i njenoj dogradnji se nalazi jedan korisnik – škola za medicinske sestre. Kompleks se sastoji od: građevine škole povezane s učeničkim domom, prostora amfiteatra i drvenog objekta u kojem se nalaze nastavni kabineti. Medicinska škola, đački dom i drveni objekt orijentirani su na Mlinarsku ulicu, dok je građevina amfiteatra uz Medvedgradsku ulicu. Južno od građevine amfiteatra, planira se dogradnja dvorane za ergonomiju. Dogradnja je sa školom povezana spojnim hodnikom na etaži kata Dogradnja se sastoji od gornje etaže (kata) gdje je smještena dvorana za ergonomiju s pratećim sanitarijama i kabinetima- spremištima medicinske opreme, te donje etaže (prizemlja) gdje su višenamjenske prostorije za edukaciju, višenamjenska učionica s pripadajućim kabinetom, sanitarije i spremište. Na etaži kata smještena je dvorana za ergonomiju koja će se prema potrebi moći podijeliti pokretnim panelima u dva dijela radi istovremenog održavanja različitih predavanja. Svi prostori u zgradi grijati će se na prosječnu temperaturu od +20 °C, sistemom centralnog grijanja prostora preko dizalice topline (COP=3,91) i plinskih bojlera. Sistem grijanja prostora je putem ventilokonvektora, radijatora i podnog grijanja, te ventilacionih komora s rekuperacijom, sve prema strojarskom projektu. Tako se ne postavljaju posebni zahtjevi za toplinsko izolacionu vrijednost pregrada između grijanih prostorija istog korisnika. Priprema medija za hlađenje (i grijanje) prostora u zgradi se radi u dizalicama topline (EER=5,05), čije vanjska jedinice su smještene u prizemlju u prostoriji spremišta sa jugozapadne strane dogradnje zgrade. Vanjske jedinice klima komora kojima se vrši ventilacija podrumskih prostorija za edukaciju i ventilacije dvorane su smještene na razini ravnog krova iznad prvog kata dogradnje zgrade sa zapadne strane zgrade. Za hlađenje zgrade preko ljetnih mjeseci, proračuni su rađeni prema Algoritmu (MGIPU, Zagreb, svibanj 2017.) na prosječnu temperaturu od +22 °C. U zgradi koja je predmet ovog projekta postoji negrijani prostor spremišta u prizemlju zgrade (jugozapadni ugao) gdje su smještene vanjske jedinice dizalice topline. Prostorije u grijanom dijelu zgrade bez zasebnih grijaćih tijela su posredno grijane prostorije. Zgrada je toplinski izolirana prema svim vanjskim i negrijanim prostorima sve u skladu sa Algoritmom (MGIPU, Zagreb, svibanj 2017.). Svi boravišni prostori u građevini imaju mogućnost prirodnog ventiliranja (mogućnost otvaranja prozora) i prirodnog osvjetljenja. Oni prostori koji nemaju prozora su umjetno ventilirani (mehanička ventilacija sa sanitarnim ventilatorima) putem ventilacionog kanala preko krova građevine. Prostorije za edukaciju i višenamjenska učionica u prizemlju te dvorana na katu imaju predviđeno mehaničko provjetravanje s izmjenjivačem topline (sustav za povrat topline – rekuperacija sa cca 89%). Potrošna topla voda (PTV) se dobiva navedenim plinskim bojlerima za vanjsku ugradnju koji služe i za grijanje zgrade.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 6

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Vrsta zgrade prema Tehničkom propisu o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) : - zgrade za obrazovanje (zgrade za osnovno i srednje obrazovanje (škola)) Klimatski podaci (vanjski) – vezano na lokaciju građevine : - Referentna meteorološka postaja: Zagreb - Grič - Nadmorska visina meteorološke postaje: 157 m - Nadmorska visina lokacije zgrade: cca 151m ( ±0,00 m = 151,46 mnv) - Srednja mjesečna temperatura vanjskog zraka, najhladnijeg mjeseca na lokaciji zgrade: Θe,mj,min [°C] = +2,3C - Srednja mjesečna temperatura vanjskog zraka, najtoplijeg mjeseca na lokaciji zgrade: Θe,mj,max [°C] = +22,8C - Referentna klima: Kontinentalna Hrvatska Klimatski podaci (unutarnji) – vezano na prostore u građevini : - prosječna unutarnja projektna temperatura grijanja unutar prostora se procjenjuje na +20C - prosječna unutarnja projektna temperatura hlađenja unutar prostora se procjenjuje na +22C - prosječna unutarnja vlažnost prostorija se procjenjuje na 30-70% Projektom su definirani svi slojevi konstrukcija, a pomoću računalnog programa su izračunati:

koeficijenti prolaska topline, difuzija vodene pare, transmisijski gubici topline, toplinski dobici, zaštita od sunčevog zračenja potrebna toplina za grijanje

Priložena je iskaznica s potrebnim podacima o zgradi. U Iskaznici energetskih svojstava zgrade su prema podatcima od glavnog projektanta i projektanta strojarskog dijela ovog glavnog projekta dani podatci zavisni o načinu grijanja i pripreme potrošne tople vode dok su prema podatcima od projektanta elektrotehničkog dijela ovog glavnog projekta dani podatci zavisni o rasvjeti, odnosno o obnovljivim izvorima energije i njihovom udjelu u ukupnoj potrebnoj energiji korištenoj u predmetnoj zgradi. U svakom pojedinom dijelu proračunskih cjelina predložene konstrukcije su zadovoljile postavljene kriterije. Tablica 1. Najveće dopuštene vrijednosti koeficijenta prolaska topline, U [W/(m²·K)], građevnih dijelova novih zgrada, i nakon rekonstrukcije postojećih zgrada:

Redni broj

Građevni dio

U [W/(m²·K)]

Θi ≥ 18 °C 12°C < Θi < 18 °C

Θe,mj, min ≤3 °C

Θe,mj, min >3 °C

Θe,mj, min ≤3 °C

Θe,mj, min >3 °C

1. Vanjski zidovi, zidovi prema garaži, zidovi prema provjetravanom tavanu

0,30 0,45 0,50 0,60

2. Prozori, balkonska vrata, krovni prozori, ostali prozirni elementi ovojnice zgrade

1,60 1,80 2,50 2,80

3. Ostakljeni dio prozora, balkonskih vrata, krovnih prozora, prozirnih elemenata ovojnice zgrade (Ug)

1,10 1,40 1,40 1,40

4. Ravni i kosi krovovi iznad grijanog prostora, stropovi prema provjetravanom tavanu

0,25 0,30 0,40 0,50

5. Stropovi iznad vanjskog zraka, stropovi iznad garaže

0,25 0,30 0,40 0,50

6. Zidovi i stropovi prema negrijanim prostorijama i negrijanom stubištu temperature više od 0°C

0,40 0,60 0,90 1,20

7. Zidovi prema tlu, podovi na tlu 0,40 0,501) 0,651) 0,801)

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 7

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

8. Vanjska vrata, vrata prema negrijanom stubištu, s neprozirnim vratnim krilom i ostakljene pregrade prema negrijanom ili provjetravanom prostoru

2,00 2,40 2,90 2,90

9. Stjenke kutija za rolete 0,60 0,80 0,80 0,80

10. Stropovi i zidovi između stanova ili između različitih grijanih posebnih dijelova zgrade (poslovni prostori i sl.)

0,60 0,80 1,20 1,20

11. Kupole i svjetlosne trake 2,50 2,50 2,50 2,50

12. Vjetrobrani, promatrano u smjeru otvaranja vrata 3,00 3,00 3,00 3,00

Napomena: Θe,mj,min je srednja mjesečna temperatura vanjskog zraka najhladnijeg mjeseca na lokaciji zgrade. 1) Kod podova na tlu zahtjev vrijedi do dubine poda prostorije 5 m od vanjskog zida, zida prema tlu ili negrijanog prostora, osim u slučaju projektiranja podnog grijanja. Sustavi u zgradi: - grijanje: dizalica topline + plinska kotlovnica (centralno plinsko, plinski bojleri) - hlađenje: dizalica topline - PTV: solarni paneli + prema potrebi preko plinskog bojlera - ventilacija: prirodna + mehanička (prisilna) bez povrata topline, za pomoćne prostorije (sanitarije) +

mehanička (prisilna) s povratom topline za neke prostorije (dvorana, prostorije za edukaciju). Za grijanje zgrade proračuni su izrađeni na pretpostavci da grijanje dizalicom topline (toplina okoline) na električnu energiju (sa COP=3,91) pokriva 70% potreba za grijanjem, dok plinsko grijanje pokriva ostalih 30% potreba. Prema tablici 8.a za proračun isporučene i primarne energije uzima se u obzir: - sustav grijanja - sustav mehaničke ventilacije i klimatizacije ukoliko postoji i - sustav rasvjete. Tablica 8.a – Definirani tehnički sustavi* za proračun isporučene i primarne energije

Vrsta zgrade SUSTAV

GRIJANJA SUSTAV

HLAĐENJA

SUSTAV PRIPREME

PTV-a

SUSTAV MEH. VENTILACIJE I

KLIMATIZACIJE

SUSTAV RASVJETE

4 Zgrade za obrazovanje DA NE NE Uzima se u obzir ukoliko postoji

DA

* Za izračun udjela obnovljivih izvora energije u ukupnoj isporučenoj energiji mogu se koristiti isporučene energije svih tehničkih sustava ugrađenih u zgradi. Proračun je proveden prema Tehničkom propisu o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015) za stvarne meteorološke podatke meteorološke postaje: Zagreb - Grič. U proračun su uzeti referentni parametri rada sustava: rad sustava s prekidom grijanja za namjenu zgrade: zgrada za obrazovanje (škola), vrijeme rada sustava grijanja određeno je u skladu sa Algoritmom za proračun potrebne energije za grijanje i hlađenje prostora zgrade prema HRN EN ISO 13790 (MGIPU, Zagreb, svibanj 2017.) za namjenu školska zgrada (08:00-20:00 sati), te iznosi 14h/dan, 5 dana u tjednu; projektna unutarnja temperatura grijanja 20°C; projektna unutarnja temperatura hlađenja 22°C; unutarnji toplinski dobitak 6 W/m2 (nestambene zgrade), prirodna ventilacija s brojem izmjena zraka u iznosu od 0,5 (1/h), odnosno mehaničko provjetravanje pomoćnih prostorija bez povrata topline (sanitarije, spremišta i sl.) + mehaničko provjetravanje nekih prostorija (višenamjenske prostorije za edukaciju, višenamjenska učionica, dvorana) s povratom topline (rekuperacija: 89%). Utjecaj toplinskih mostova uzet je u obzir povećanjem koeficijenata prolaska topline U (W/m2K) svakog građevinskog dijela oplošja grijanog dijela zgrade za UTM=0,05 W/m2K uz obavezno izvođenje toplinskih mostova prema Prilogu D – Katalogu dobro riješenih toplinskih mostova na zgradama u skladu sa zahtjevima iz članka 33. stavak 3. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018). Prema podatcima iz strojarskog projekta u prostorima građevine se za rad sustava u zgradi koristi oko 46,71% energije iz obnovljivih izvora energije: grijanje (i hlađenje) sa dizalicom topline. Time je prema članku 42. stavku 2 paragrafu

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 8

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

1 Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018), ispunjen zahtjev u pogledu primjene obnovljivih izvora energije, te jedan od parametara u pogledu zahtjeva zgrade za kategorijom nZEB (>30%). Drugi parametar za ispunjenje zahtjeva zgrade za kategorijom nZEB je da je Eprim niža od vrijednosti iskazanih u tablici 8 istog pravilnika, odnosno da je Eprim < 55 [kWh/(m²·a)]. Kako je Eprim = 37,78 [kWh/(m²·a)] i drugi parametar u pogledu zahtjeva zgrade za kategorijom nZEB je zadovoljen. Time predmetna zgrada zadovoljava kategoriju nZEB. OPASKA: Vrijednosti izračunate godišnje potrebne toplinske energije za grijanje i godišnje potrebne toplinske energije za hlađenje po jedinici ploštine korisne površine zgrade za stvarne klimatske podatke Q’’H,nd [kWh/(m²·a)] i Q’’C,nd [kWh/(m²·a)] (za stambene ili nestambene zgrade) zadovoljavaju i kada su veće od dopuštenih vrijednosti, ukoliko je specifična vrijednosti Eprim niža za najmanje 20% od dopuštene vrijednosti prema članku 45. stavak (8) Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018). Kako je dopuštene vrijednost Eprim = 65,00 [kWh/(m²·a)], a izračunata vrijednost Eprim = 37,78 [kWh/(m²·a)], to je niže za 41,87%; te time Q"H,nd [kWh/(m²·a)] i Q"C,nd [kWh/(m²·a)] viši od propisanih zadovoljavaju. 1.2. Konstrukcija Nosiva konstrukcija su armiranobetonski zidovi debljine 20cm, 25cm i 30cm, ukrućeni punim armiranobetonskim pločama debljine 22cm. Zgrada je temeljena na trakastim temeljima koji su povezani podnom armiranobetonskom pločom debljine 20cm. U podu prema tlu grijanih prostorija prizemlja ispod lagano armirane betonske podloge (tzv. cementne glazure) su ugrađene ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 10 cm, te 2 cm elastificiranog ekspandiranog polistirena EPS-T koji je u funkciji i toplinske i zvučne izolacije. U podu prema tlu grijanih prostorija kata ispod lagano armirane betonske podloge (tzv. cementne glazure) su ugrađene ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 5 cm, te 2 cm elastificiranog ekspandiranog polistirena EPS-T koji je u funkciji i toplinske i zvučne izolacije, dok se ispod podne ploče ugrađuje još sloj ekstrudiranog polistirena XPS debljine 5 cm. U podu prema tlu negrijanog prostora spremišta u prizemlju ispod lagano armirane betonske podloge (tzv. cementne glazure) su ugrađene ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 6 cm, te 2 cm elastificiranog ekspandiranog polistirena EPS-T koji je u funkciji i toplinske i zvučne izolacije. Toplinska izolacija je postavljena radi sprečavanja toplinskih mostova na konstrukcijama. Međukatna konstrukcija je predviđena kao puna armiranobetonska stropna ploče debljine 22 cm. Sve međukatne konstrukcije i podovi na tlu predviđene su u izvedbi s prigušnim slojem elastificiranog ekspandiranog polistirena kao prvenstveno zvučnom izolacijom između etaža ("plivajući pod"). U plivajućem podu međukatnih konstrukcija osim 2 cm elastificiranog ekspandiranog polistirena EPS-T se nalaze još dodatno i ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 1cm odnosno 5cm (ovisno o poziciji na kojoj se nalazi). U podgled međukatne konstrukcije iznad otvorenog gdje je predviđeno ventilirano pročelje, prema grijanom prostoru iznad predviđena je postava toplinske izolacije sa fasadnim pločama mineralne vune za ventilirano pročelje debljine 16 cm (ploče kao Knauf Insulation ploče za ventilirane fasade s crnim voalom NaturBoard Ventacusto GVB ili NaturBoard Venti GVB ili jednakovrijedan materijal), sa završnom oblogom ventiliranog pročelja na podkonstrukciji prema izboru projektanta, sve izvedeno prema preporukama proizvođača ventiliranog pročelja. U podgled međukatne konstrukcije iznad negrijanog prostora spremišta u prizemlju, prema grijanom prostoru iznad predviđena je postava toplinske izolacije fasadnim pločama od mineralne vune (kao Knauf Insulation ploče za kontaktne fasade FKD S Thermal ili jednakovrijedan materijal) debljine 5 cm, sa završnom polimercementnom žbukom, kao kompaktni fasadni sustav, sve izvedeno prema preporukama proizvođača za izvedbu žbuke na pločama mineralne vune (ETICS fasada). U plivajućem podu iznad osim 2 cm elastificiranog ekspandiranog polistirena EPS-T nalaze se još dodatno i ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 1cm.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 9

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Krov iznad dvorane je laki ravni zeleni krov sa čeličnom konstrukcijom kao slagani krov, sa kompaktnim pločama od tvrde mineralne vune debljine 25 cm položenom na trapezni profilirani lim (kao Knauf Insulation ploče za ravne krovove SMARTROOF thermal debljine 15 cm + Knauf Insulation ploče za ravne krovove SMARTROOF TOP debljine 10 cm ili jednakovrijedni materijali). Ispod toplinske izolacije je potrebno postaviti parnu branu, dok je iznad predviđena hidroizolacijska traka na bazi FPO/TPO-a. Iznad hidroizolacije je predviđen ploča ekstrudiranog polistirena XPS debljine 5 cm kao dodatna zaštita hidroizolacije od slojeva zelenog krova. Navedeni laki krov je predviđen kao zeleni krov, sve izvedeno prema preporukama proizvođača zelenih krovova. Iznad nižeg dijela kata postoji ravni teški neprohodni krov sa teškom armiranobetonskom pločom debljine 16 cm kao nosivim dijelom krova. Toplinska izolacija krova je predviđena pločama ekstrudiranog polistirena XPS debljine 30 cm položenim na armiranobetonsku ploču, te hidroizolacijom krova postavljenom iznad toplinske izolacije i parnom branom ispod toplinske izolacije. Kao završna obloga krova je predviđen zaštitni sloj oblutaka. Vanjski zidovi od armiranog betona su obloženi toplinskom izolacijom sa fasadnim pločama mineralne vune za ventilirano pročelje debljine 14cm u prizemlju i 16cm na katu (ploče kao Knauf Insulation ploče za ventilirane fasade s crnim voalom NaturBoard Ventacusto GVB ili NaturBoard Venti GVB ili jednakovrijedan materijal), sa završnom oblogom ventiliranog pročelja na podkonstrukciji prema izboru projektanta, sve izvedeno prema preporukama proizvođača ventiliranog pročelja. Kod podnožja vanjskih zidova izloženih prskanju kiše toplinska izolacija se izvodi s pločama ekstrudiranog polistirena XPS minimalne debljine 12cm odnosno 14cm, sa završnom polimercementnom žbukom ili sl., kao kompaktni fasadni sustav sokla iznad tla / terasa. Vanjski zid zapadnog pročelja zgrade iznad razine prvog kata je armiranobetonski predviđen kao ETICS fasada, s predviđenom toplinskom izolacijom od mineralne vune za ETICS fasade (kao Knauf Insulation ploče za kontaktne fasade FKD S Thermal) debljine 16 cm, sa završnom polimercementnom žbukom, kao kompaktni fasadni sustav, sve izvedeno prema preporukama proizvođača za izvedbu žbuke na pločama mineralne vune (ETICS fasada). Armiranobetonski zid grijanog prostora prema negrijanom prostoru spremišta u prizemlju su obloženi toplinskom izolacijom fasadnim pločama od mineralne vune (kao Knauf Insulation ploče za kontaktne fasade FKD S Thermal ili jednakovrijedan materijal) debljine 10 cm, sa završnom polimercementnom žbukom, kao kompaktni fasadni sustav, sve izvedeno prema preporukama proizvođača za izvedbu žbuke na pločama mineralne vune (ETICS fasada). Zidovi prema tlu predviđeni sa dodatnom toplinskom izolacijom s vanjske strane nosivog zida, toplinsko izolacijskim pločama ekstrudiranog polistirena XPS debljine 12 cm te zaštićeni hidroizolacijom. Zid između grijanog i negrijanog dijela prizemlja koji je predviđen kao laka montažna pregradna stijena je od gipskartonskih ploča kao tipa Knauf Diamant ploče na metalnoj podkonstrukciji (debljine 15 cm), s ispunom međuprostora mineralnom vunom (kao Knauf Insulation filc za pregradne zidove TI 140 W, Knauf Insulation ECOSE filc za pregradne zidove DECIBEL ili jednakovrijedni materijal debljine 10 cm), s obavezno postavljenom parnom branom s toplije strane toplinske izolacije. Unutarnji novi pregradni zidovi su predviđeni kao lake montažne pregradne stijene od gipskartonskih ploča na metalnoj podkonstrukciji (debljine minimalno 10 cm), s ispunom međuprostora mineralnom vunom (kao Knauf Insulation filc za pregradne zidove TI 140 W, Knauf Insulation ECOSE filc za pregradne zidove DECIBEL ili jednakovrijedni materijal debljine 5 cm). Pregrade je potrebno izvoditi do nosive konstrukcije, iznad razine spuštenog stropa (ukoliko on postoji kao interijerska završna obrada stropa). Kod zidova gdje je potrebna bolja zvučna izolacija između različitih prostorija predviđena je upotreba gipskartonskih ploča kao tipa Knauf Diamant ploče umjesto običnih gipskartonskih ploča (zidovi učionice, dvorane, prostorija za edukaciju, kabineta i sl) debljine 15 cm ispunjenu mineralnom vunom debljine 10cm. Iz razloga zvučne izolacije se projektirana debljina zida ne smije tanjiti (prilikom montiranja instalacija), te je iz razloga provođenja instalacija potrebno izvoditi dodatni parapetni zid (u prostorijama sanitarija). Sva unutarnja stolarija je predviđena drvena. Prozori, ostakljena ulazna vrata i staklene stijene su predviđene u plastificiranim aluminijskim okvirima, s prekinutim toplinskim mostom i toplinski poboljšanim svojstvima, ostakljenje IZO staklom; dva sloja stakla 4+16+6 mm (4 LowE

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 10

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

+ 16/argon + 6). Minimalni razmak između stakla je 12 mm, jedno staklo mora biti low energie staklo (vanjska strana unutarnjeg stakla), a međurazmak je ispunjen plinom argonom. Prema potrebi unutarnje staklo sigurnosno lamelirano – veće staklene površine i prema potrebi prostora. Prozori imaju mogućnost otvaranja zbog prirodne ventilacije prostora. Prozori i balkonska vrata su otklopno zaokretni ili klizni. Zaštita od sunčevog zračenja: Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60. Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i maksimalnim g = 0,60. Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od sunca je riješena s mutnim neprozirnim staklom s g = 0,60. Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite od sunca je riješena sa staklom koje ima g = 0,33. Vanjska vrata grijanih prostora - neprozirno vratno krilo su predviđena u plastificiranim aluminijskim okvirima s prekinutim toplinskim mostom i toplinski poboljšanim svojstvima te s ispunom punog glatkog sendvič krila toplinskom izolacijom. Moguće je manje ostakljenje IZO staklo 4+12+4 mm, a ispuna (sendvič panel) prema izboru projektanta. Vrata grijanog prostora prema negrijanom prostoru (spremište u prizemlju) su protupožarna vrata, predviđena od metalnih okvira s prekidom toplinskog mosta i toplinski poboljšanim svojstvima. Ispunom punog glatkog sendvič krila toplinskom izolacijom. 1.3. Koncepcija toplinske zaštite Toplinska zaštita se ostvaruje dodatnim toplinsko izolacijskim pločama odnosno na slijedeći način: - u podovima grijanog prostora prizemlja na tlu je debljina ploča samogasivog ekspandiranog polistirena EPS-150

ili EPS-100 od 10 cm + elastificirani polistiren debljine 2 cm (1+1 cm). - u podovima grijanog prostora kata na tlu je debljina ploča samogasivog ekstrudiranog polistirena XPS 5 cm (ispod

podne ploče) + samogasivi ekspandirani polistiren EPS-150 ili EPS-100 od 5 cm + elastificirani polistiren debljine 2 cm (1+1 cm).

- u podovima negrijanog prostora spremišta u prizemlju na tlu je debljina ploča samogasivog ekspandiranog polistirena EPS-150 ili EPS-100 od 6 cm + elastificirani polistiren debljine 2 cm (1+1 cm) – toplinski mostovi.

- u plivajućem podu međukatne konstrukcije ugrađuju se ploče ekspandiranog polistirena EPS-150 ili EPS-100 od 1 cm + elastificirani polistiren debljine 2 cm (1+1 cm) - dvorana.

- u plivajućem podu međukatne konstrukcije ugrađuju se ploče ekspandiranog polistirena EPS-150 ili EPS-100 od 5 cm + elastificirani polistiren debljine 2 cm (1+1 cm).

- u međukatnoj konstrukciji grijanog prostora iznad vanjskog prostora se dodatno s donje strane armiranobetonske ploče postavljaju ploče mineralne vune debljine 16 cm, ploče kamene vune (kao Knauf Insulation ploča za ventilirane fasade s crnim voalom NaturBoard Venti GVB ili NaturBoard Ventacusto GVB ili jednakovrijedan materijal) naknadno učvršćene na podgled vijcima sa širokom glavom (kao ventilirana fasada)

- u međukatnoj konstrukciji grijanog prostora iznad negrijanog prostora spremišta u prizemlju se dodatno s donje strane armiranobetonske ploče postavljaju ploče mineralne vune debljine 5 cm, ploče kamene vune (kao Knauf Insulation ploče za kontaktne fasade FKD S Thermal ili jednakovrijedan materijal) naknadno učvršćene na podgled vijcima sa širokom glavom (s tankoslojnom žbukom kao završnom podgleda stropa – ETICS fasada)

- u lakom ravnom zelenom krovu ugrađuju se kompaktne meke ploče mineralne vune ukupne debljine 25 cm (kao Knauf Insulation ploča za ravne krovove SMARTROOF THERMAL debljine 15cm + Knauf Insulation ploča za ravne krovove SMARTROOF TOP debljine 10 cm ili jednakovrijedni materijali) + kao dodatna zaštita ploče samogasivog ekstrudiranog polistirena XPS debljine 5cm, te s hidroizolacijom krova postavljenom iznad mineralne vune i parnom branom ispod toplinske izolacije.

- u teškom ravnom neprohodnom krovu iznad kata (niži dio) ugrađuju se ploče samogasivog ekstrudiranog polistirena XPS debljine 30 cm, položene na armiranobetonsku ploču, te s hidroizolacijom krova postavljenom iznad toplinske izolacije i parnom branom ispod toplinske izolacije.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 11

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- u zidovima prema tlu s vanjske strane se na hidroizolaciju postavlja obloga od ekstrudiranog polistirena XPS debljine 12 cm kao toplinska izolacija tog dijela zida.

- vanjski zidovi prizemlja koji su predviđeni u izvedbi kao ventilirano pročelje, su s vanjske strane obloženi pločama mineralne vune debljine 14 cm (kao Knauf Insulation ploče za ventilirane fasade s crnim voalom NaturBoard Ventacusto GVB ili NaturBoard Venti GVB ili jednakovrijedan materijal) sa završnom oblogom ventiliranog pročelja na podkonstrukciji prema izboru projektanta kao završnom oblogom.

- vanjski zidovi kata koji su predviđeni u izvedbi kao ventilirano pročelje, su s vanjske strane obloženi pločama mineralne vune debljine 16 cm (kao Knauf Insulation ploče za ventilirane fasade s crnim voalom NaturBoard Ventacusto GVB ili NaturBoard Venti GVB ili jednakovrijedan materijal) sa završnom oblogom ventiliranog pročelja na podkonstrukciji prema izboru projektanta kao završnom oblogom.

- vanjski zid zapadnog pročelja iznad kata je predviđen s tankoslojnom žbukom kao završnom obradom zida, te je s vanjske strane obložen fasadnim pločama mineralne vune debljine 16 cm (kao Knauf Insulation ploča za kontaktne fasade FKD S Thermal ili jednakovrijedan materijal), koje su naknadno učvršćene na zid vijcima sa širokom glavom (s tankoslojnom žbukom kao završnom obradom zida – ETICS fasada).

- u soklu vanjskog zida iznad terena (kontaktna vlažna zona) s vanjske strane se na hidroizolaciju postavlja obloga od ekstrudiranog polistirena XPS debljine 12cm u prizemlju i 14cm na katu kao toplinska izolacija tog dijela zida.

- laki pregradni zid između grijanog i negrijanog dijela prizemlja se predviđa kao tipa Knauf Diamant pregradni zid W112 debljine 15,0 cm čija metalna podkonstrukcija se ispunjava mineralnom vunom (kao Knauf Insulation filc za pregradne zidove TI 140 W, Knauf Insulation ECOSE filc za pregradne zidove DECIBEL ili jednakovrijedan materijal) debljine 10 cm, s obavezno postavljenom parnom branom s toplije strane toplinske izolacije.

- armiranobetonski zid grijanog prostora prema negrijanom je predviđen s tankoslojnom žbukom kao završnom obradom zida, te je s hladnije strane obložen fasadnim pločama mineralne vune debljine 10 cm (kao Knauf Insulation ploča za kontaktne fasade FKD S Thermal ili jednakovrijedan materijal), koje su naknadno učvršćene na zid vijcima sa širokom glavom (s tankoslojnom žbukom kao završnom obradom zida – ETICS fasada).

Sve obodne konstrukcije predviđene su tako da se postižu dobre vrijednosti toplinske zaštite, da konstrukcije izložene velikim temperaturnim promjenama budu stabilne, da plošna temperatura obodnih konstrukcija grijanih prostora bude zadovoljavajuća, te da unutar sastava obodnih konstrukcija ne dolazi do stvaranja kondenzata vodene pare koja se neće moći isušiti. Sve konstrukcije s istakama iz obodnih konstrukcija grijanih prostora prema otvorenom prostoru (toplinski mostovi - istake iz zidova ili stropnih ploča) moraju biti obostrano prevučene slojem toplinske izolacije u vidu ploča mineralne vune ili (odgovarajućeg) polistirena (EPS-F, XPS), minimalne debljine 8 cm odnosno mineralnih termoizolacijskih ploča Ytong Multipor ili kombi pločama debljine 10 cm, s odgovarajućim završnim slojem (obloga gipskartonskim pločama, žbuka i sl.), u duljini minimalno 100 cm od kontakta izolirane površine i istake, kako bi se produljili toplinski mostovi. Sve površine obodnih konstrukcija moraju biti neizostavno izvedene sa oblogom od toplinske izolacije. 1.4. Strojarske instalacije - grijanje, ventilacija, klimatizacija Kratki opis iz strojarskog projekta: 4.1.1.GRIJANJE I HLAĐENJE- VRV SUSTAV Za potrebe grijanja dijela građevine; predviđen je direktni koncept grijanja i hlađenja putem zrakom hlađenih dizalica topline s promjenjivimvolumenomradne tvari (VRV sustav). VRV sustav s direktnom ekspanzijom radnog medija sastoji se od većeg broja unutarnjih jedinica(isparivača/kondenzatora) spojenih na jednu vanjsku (kondenzator + kompresor). … Vanjske jedinice smještene su u zasebnoj prostoriji u prizemlju. Moduli se postavljaju na postolje izrađeno iz čeličnih kvadratnih profila. Između postolja i jedinice postavljaju se gumeni antivibracijski podlošci. Prilikom postavljanja jedinice potrebno se pridržavati minimalnih potrebnih udaljenoisti od bočnih zidova, te minimalne potrebne visine ugradnje. Ovisno o konfiguraciji prostorija potrebnih za grijanje/hlađenje, izabrane su slj. unutarnje jedinice VRV sustava: Parapetna podna jedinica… zidna jedinica… ili kazetna četverosmjerna jedinica - ugradbena. … 4.1.2.GRIJANJE VODENI SUSTAV

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 12

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Za pripremu ogrjevne i rashladne vode za potrebe podnog grijanja predviđen je kondenzacijski kotao modularne izvedbe ukupne toplinske snage 230kW, tipa Power Plus Box 1002 P EXT, proizvođača BERETTA, EWAQ025CWP. Kotao se nalazi na krovu prema postojećem dijelu škole. VODENO PODNO GRIJANJE/HLAĐENJE SANITARIJA I GARDEROBA Grijanje sanitarija i grderoba riješeno je podnim površinskim grijanjem. Sustav podnog grijanja priključuje se na toplinski sustav kondenzacijskog kotla na krovu zgrade. Predviđeni temperaturni režim podnog grijanja iznosi 40/37ºC. … GRIJANJE DVORANE Grijanje dvorane riješeno je pomoću radijatora koji su temeljni sustav i ventilacijske komore koja je dodatni sustav. 4.1. VENTILACIJA Sve prostorije koje nemaju vlastite prozore za provjetravanje, trebaju biti ventilirane prisilno pomoću ventilatora i ventilacijskih kanala. Zadatak ventilacije u takvim prostorijama je izmjena zraka radi održavanja vlažnosti zraka, čistoće i kretanja zraka po normativima koji odgovaraju potrebama čovjekovog zdravlja i ugodnog boravka. …. 4.2.1. VENTILACIJA DVORANE ZA ERGONOMIJU Za potrebe ventiliranja dvorane za ergonomiju i kabineta u prizemlju predviđena je prisilna ventilacija putem klima komore (KK1) s povratom topline (rekuperatorska jedinica),. Rekuperatorska - ventilacijska jedinica kompaktnemonoblock izvedbe, opremljena je sa visokoučinskim pločastim rekuperatorom (temperaturna učinkovitost 89%), tlačnim i odsisnim elektronički upravljanim ventilatorima, filterima klase M5 i prigušivačima na tlačnom i odsisnom kanalu, te svim potrebnim elementima za zaštitu, kontrolu i regulaciju uređaja. Klima komora je smještena na ravnom dijelu krova prema postojećem dijelu građevine. Prilikom postavljanja jedinice potrebno se pridržavati minimalnih potrebnih servisnih udaljenoisti od bočnih zidova, te minimalne potrebne visine ugradnje. Zrak se od komore do usisnih i odsisnih mjesta distribuira putem limenih pocinčanih kanala, odgovarajućih dimenzija, vođenih u spuštenom stropu. Kanali svježeg i otpadnog zraka izoliraju se paronepropusom izolacijom od kamene vune tipa Larock, kao proizvod Rockwool, debljine prema specifikaciji. Odsisavanje zraka vrši se preko zračnih odsisnih ventila tipa LVS, proizvod kao TROX,. Na granama tlačnih kanala ugrađeni su regulatori konstantnog protoka, tipa VFL, proizvod kao TROX, za automatsku regulaciju protoka. Kako bi se omogučilo strujanje zraka od mjesta ubacivanja do mjesta odsisavanja (sanitarije) zraka vrata između prostorija potrebno je podrezati ili na ista ugraditi adekvatne prestrujne rešetke. … 4.2.1. VENTILACIJA VIŠENAMJENSKIH PROSTORIJA ZA EDUKACIJU Za potrebe ventiliranja višenamjenskih prostorija u prizemlju predviđena je prisilna ventilacija putem klima komore (KK2) s povratom topline (rekuperatorska jedinica),. Rekuperatorska - ventilacijska jedinica kompaktnemonoblock izvedbe, opremljena je sa visokoučinskim pločastim rekuperatorom (temperaturna učinkovitost 89%), tlačnim i odsisnim elektronički upravljanim ventilatorima, filterima klase M5 i prigušivačima na tlačnom i odsisnom kanalu, te svim potrebnim elementima za zaštitu, kontrolu i regulaciju uređaja. Klima komora je smještena na ravnom dijelu krova prema postojećem dijelu građevine. Prilikom postavljanja jedinice potrebno se pridržavati minimalnih potrebnih servisnih udaljenoisti od bočnih zidova, te minimalne potrebne visine ugradnje. Zrak se od komore do usisnih i odsisnih mjesta distribuira putem limenih pocinčanih kanala, odgovarajućih dimenzija, vođenih u spuštenom stropu. Kanali svježeg i otpadnog zraka izoliraju se paronepropusom izolacijom od kamene vune tipa Larock, kao proizvod Rockwool, debljine prema specifikaciji. … 4.2.3. VENTILACIJA SANITARIJA Ventilacija sanitarija predviđena je putem nadžbuknih ventilatora tipa ER-100-VZ količine odsisa 100 m3/h, kao proizvod MAICO. Ventilatori imaju ugrađeni timer koji odgađa početak rada nakon paljenja putem strujne sklopke i odgađa prestanak rada ventilatora za 6 min nakon gašenja putem sklopke. Ventilatori se priključuju na zajednički ventilacijskikanal, a otpadni zrak izbacuje se u okolinu preko krova građevine. … Odsisani zrak iz prostorija nadomješta se zrakom iz susjednih prostorija preko prestrujnih rešetki, odnosno zazora ispod vrata (usaglasiti sa dobavljačem unutarnje stolarije i arhitektom). Projektant : Darko Bailo, dipl.ing.stroj.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 13

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

2. SLOJEVI OBODNIH KONSTRUKCIJA (slojevi prikazani odozgo prema dolje kod horizontalnih konstrukcija, te iznutra prema van kod vertikalnih) Konstrukcija istake iz obodnih konstrukcija grijanih prostora prema otvorenom odnosno negrijanom prostoru (toplinski mostovi - istake iz zidova ili stropnih ploča) mora biti obostrano prevučena slojem toplinske izolacije minimalne debljine 8 cm s odgovarajućim završnim slojem, u duljini minimalno 100 cm od kontakta izolirane površine i istake, kako bi se produljili toplinski mostovi. Vidi rješenja toplinskih mostova u Katalogu dobro riješenih toplinskih mostova na zgradama – prilog D Tehničkog propisa (NN 128/2015). Ili su riješena ugradnjom odgovarajućih Isokorb elemenata. Sve toplinske mostove obavezno rješavati prema Katalogu dobro riješenih toplinskih mostova na zgradama – prilog D Tehničkog propisa (NN 128/2015). Prema Prikazu mjera zaštite od požara i članku 4. Pravilnika o otpornosti na požar i drugim zahtjevima koje građevine moraju zadovoljiti u slučaju požara (NN 029/2013, 087/2015) predmetna zgrada se nalazi u podskupini ZPS3 prema zahtjevnosti zaštite od požara. Podovi na tlu : Kod svih "plivajućih podova" gornja ploča iznad mekoelastičnog sloja elastificiranog ekspandiranog polistirena (EPS-T) mora biti bočno odijeljena od zidova vertikalnom trakom EPS-a debljine 1 cm; gornji slojevi su "plivajući"; PE foliju podignuti vertikalno uz rubove. ZPS3: kod izvedbe podnih konstrukcija toplinska izolacija može biti razreda reakcije na požar E, uz uvjet da je nosiva podna konstrukcija razreda reakcije na požar A2 propisane otpornosti na požar (armiranobetonska ploča), te da se iznad toplinske izolacije nalazi sloj materijala od najmanje 5 cm debljine razreda reakcije na požar A2 (cementna glazura i sl.), odnosno da ne postoji mogućnost izravnog prijenosa požara na toplinsku izolaciju, prema mišljenju Ministarstva unutarnjih poslova, Uprava za upravne i inspekcijske poslove, Sektor za inspekcijske poslove, Zagreb (Mišljenje, Klasa: 214-02/18-21/4, Urbroj: 511-01-208-18-2 od 18. siječnja 2018. godine). P1 Pod na tlu grijanog prostora u prizemlju

- završna hodna obloga – ovisno o namjeni prostora: poliuretanski lijevani pod, lijepljene protuklizne gres keramičke pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje) ili jednakovrijedan materijal, izvedba sa svim potrebnim predradnjama i prema uputama proizvođača odabranog materijala (podna obloga na evakuacijskim putevima ima reakciju na požar najmanje Cfl-s1 za ZPS3)

≥ 0,5 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

10 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- hidroizolacija trakama za zavarivanje – dvije trake (1000 kg/m3) / polimer-bitumenska traka s uloškom staklene tkanine u dva sloja (kao 2x GV4) (Klasa gorivosti po HRN EN 13501-1: E)

cca 1 cm

- hladni bitumenski prednamaz (Klasa gorivosti po HRN EN 13501-1: E) -

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 14

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- armiranobetonska podna ploča (2500 kg/m3) zaglađene gornje površine pogodne za postavu odabrane hidroizolacije, sve prema uputama proizvođača hidroizolacije (Klasa gorivosti po HRN EN 13501-1: A1)

20 cm

- polietilenska folija (1000 kg/m3), prema potrebi (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - nabijeno tlo / zamjenski kameni agregat (ovisno o terenu) / nasip dobro nabijene batude (dobro nabijena u dva sloja) ≥ 20 cm

-

U = 0,28 W/m2K < 0,40 W/m2K ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. P2 Pod na tlu u sanitarijama grijanog prostora u prizemlju

- završna hodna obloga - lijepljene protuklizne keramičke pločice, lijepljene protuklizne gres porculanske pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje na navedenoj hidroizolaciji), sve izvedeno prema uputama za izvedbu odabrane završne obrade poda (Klasa gorivosti po HRN EN 13501-1: A1)

≥ 1 cm

- visoko elastični cementni mort za HI u vlažnim prostorijama, d=2-4 mm, hidroizolacija tipa kao Mapelastic + mrežica Mapenet 150 ili Sikalastic 152 ili neki drugi hidroizolacijski elastični premaz istih karakteristika (jednakovrijedan materijal), izvedba prema smjernicama proizvođača (Klasa gorivosti po HRN EN 13501-1 za Sikalastic 152: C-s1, d0)

0,2 – 0,4 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

10 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- hidroizolacija trakama za zavarivanje – dvije trake (1000 kg/m3) / polimer-bitumenska traka s uloškom staklene tkanine u dva sloja (kao 2x GV4) (Klasa gorivosti po HRN EN 13501-1: E)

cca 1 cm

- hladni bitumenski prednamaz (Klasa gorivosti po HRN EN 13501-1: E) - - armiranobetonska podna ploča (2500 kg/m3) zaglađene gornje površine pogodne za postavu odabrane hidroizolacije, sve prema uputama proizvođača hidroizolacije (Klasa gorivosti po HRN EN 13501-1: A1)

20 cm

- polietilenska folija (1000 kg/m3), prema potrebi (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - nabijeno tlo / zamjenski kameni agregat (ovisno o terenu) / nasip dobro nabijene batude (dobro nabijena u dva sloja) ≥ 20 cm

-

U = 0,28 W/m2K < 0,40 W/m2K ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 15

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

P3 Pod na tlu u sanitarijama grijanog prostora u prizemlju + podno grijanje - završna hodna obloga - lijepljene protuklizne keramičke pločice, lijepljene protuklizne gres porculanske pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje na navedenoj hidroizolaciji i podnom grijanju), sve izvedeno prema uputama za izvedbu odabrane završne obrade poda (Klasa gorivosti po HRN EN 13501-1: A1)

≥ 1 cm

- visoko elastični cementni mort za HI u vlažnim prostorijama, d=2-4 mm, hidroizolacija tipa kao Mapelastic + mrežica Mapenet 150 ili Sikalastic 152 ili neki drugi hidroizolacijski elastični premaz istih karakteristika (jednakovrijedan materijal), izvedba prema smjernicama proizvođača (Klasa gorivosti po HRN EN 13501-1 za Sikalastic 152: C-s1, d0)

0,2 – 0,4 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje s dodatkom aditiva ECO30 i aditiva VD450; minimalna debljina sloja iznad cijevi podnog grijanja je 4 cm, odnosno ukupno minimalno 6,5 cm zajedno sa cijevima podnog grijanja (Klasa gorivosti po HRN EN 13501-1: A1)

≥ 4 cm

- cijevi podnog grijanja s nosačima – sistem cijevi REHAU i EUROVAL modularne letvice oko kojih se motaju ovalne cijevi ili sistem cijevi ROTEX koje se postavljaju na tipske podložne ploče sa čepovima ispod kojih je postavljen sloj izolacije (stiropor) od 2,5cm ili jednakovrijedni materijali

2,5 cm

- polietilenska folija (1000 kg/m3), preklopi od 20 cm; postavlja se u funkciji razdjelnog sloja i parne brane u vidu sprječavanja prodora kondenzata / vlage prema slojevima poda s podnim grijanjem, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

10 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- hidroizolacija trakama za zavarivanje – dvije trake (1000 kg/m3) / polimer-bitumenska traka s uloškom staklene tkanine u dva sloja (kao 2x GV4) (Klasa gorivosti po HRN EN 13501-1: E)

cca 1 cm

- hladni bitumenski prednamaz (Klasa gorivosti po HRN EN 13501-1: E) - - armiranobetonska podna ploča (2500 kg/m3) zaglađene gornje površine pogodne za postavu odabrane hidroizolacije, sve prema uputama proizvođača hidroizolacije (Klasa gorivosti po HRN EN 13501-1: A1)

20 cm

- polietilenska folija (1000 kg/m3), prema potrebi (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - nabijeno tlo / zamjenski kameni agregat (ovisno o terenu) / nasip dobro nabijene batude (dobro nabijena u dva sloja) ≥ 20 cm

-

U = 0,28 W/m2K < 0,40 W/m2K U = 0,28 W/m2K < 0,30 W/m2K – podno grijanje ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. P4 Pod na tlu negrijanog prostora u prizemlju

- završna hodna obloga – ovisno o namjeni prostora: lijepljene protuklizne gres keramičke pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje) ili jednakovrijedan materijal, izvedba sa svim potrebnim predradnjama i prema uputama proizvođača odabranog materijala (podna obloga na evakuacijskim putevima ima reakciju na požar najmanje Cfl-s1 za ZPS3)

≥ 1 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 16

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

6 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- hidroizolacija trakama za zavarivanje – dvije trake (1000 kg/m3) / polimer-bitumenska traka s uloškom staklene tkanine u dva sloja (kao 2x GV4) (Klasa gorivosti po HRN EN 13501-1: E)

cca 1 cm

- hladni bitumenski prednamaz (Klasa gorivosti po HRN EN 13501-1: E) - - armiranobetonska podna ploča (2500 kg/m3) zaglađene gornje površine pogodne za postavu odabrane hidroizolacije, sve prema uputama proizvođača hidroizolacije (Klasa gorivosti po HRN EN 13501-1: A1)

20 cm

- polietilenska folija (1000 kg/m3), prema potrebi (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - nabijeno tlo / zamjenski kameni agregat (ovisno o terenu) / nasip dobro nabijene batude (dobro nabijena u dva sloja) ≥ 20 cm

-

U = 0,40 W/m2K ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. P5 Pod na tlu grijanog prostora na katu

- završna hodna obloga – ovisno o namjeni prostora: poliuretanski lijevani pod, lijepljene protuklizne gres keramičke pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje) ili jednakovrijedan materijal, izvedba sa svim potrebnim predradnjama i prema uputama proizvođača odabranog materijala (podna obloga na evakuacijskim putevima ima reakciju na požar najmanje Cfl-s1 za ZPS3)

≥ 0,5 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

5 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- armiranobetonska stropna/podna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

22 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - ploče ekstrudiranog polistirena XPS (cca 40 kg/m3); (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,033 W/mK, Klasa gorivosti po HRN EN 13501-1: E)

5 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 17

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- varena PVC hidroizolacija (1000 kg/m3); poput: Sika (Sikaplan WP 1100-15 HL) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E) ili hidroizolacija TPO/FPO membrana (1000 kg/m3); poput: Sika (Sikaplan WT 1200-16, FPO-PE) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E)

0,15 – 0,2 cm

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- donja betonska podloga, armirana i zaglađena (2500 kg/m3) zaglađene gornje površine pogodne za postavu odabrane hidroizolacije, sve prema uputama proizvođača hidroizolacije (Klasa gorivosti po HRN EN 13501-1: A1)

cca 10 cm

- polietilenska folija (1000 kg/m3), prema potrebi (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - nabijeno tlo / zamjenski kameni agregat (ovisno o terenu) / nasip dobro nabijene batude (dobro nabijena u dva sloja) ≥ 20 cm

-

U = 0,27 W/m2K < 0,40 W/m2K ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. P6 Pod na tlu u sanitarijama grijanog prostora na katu + podno grijanje

- završna hodna obloga - lijepljene protuklizne keramičke pločice, lijepljene protuklizne gres porculanske pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje na navedenoj hidroizolaciji i podnom grijanju), sve izvedeno prema uputama za izvedbu odabrane završne obrade poda (Klasa gorivosti po HRN EN 13501-1: A1)

≥ 1 cm

- visoko elastični cementni mort za HI u vlažnim prostorijama, d=2-4 mm, hidroizolacija tipa kao Mapelastic + mrežica Mapenet 150 ili Sikalastic 152 ili neki drugi hidroizolacijski elastični premaz istih karakteristika (jednakovrijedan materijal), izvedba prema smjernicama proizvođača (Klasa gorivosti po HRN EN 13501-1 za Sikalastic 152: C-s1, d0)

0,2 – 0,4 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje s dodatkom aditiva ECO30 i aditiva VD450; minimalna debljina sloja iznad cijevi podnog grijanja je 4 cm, odnosno ukupno minimalno 6,5 cm zajedno sa cijevima podnog grijanja (Klasa gorivosti po HRN EN 13501-1: A1)

≥ 4 cm

- cijevi podnog grijanja s nosačima – sistem cijevi REHAU i EUROVAL modularne letvice oko kojih se motaju ovalne cijevi ili sistem cijevi ROTEX koje se postavljaju na tipske podložne ploče sa čepovima ispod kojih je postavljen sloj izolacije (stiropor) od 2,5cm ili jednakovrijedni materijali

2,5 cm

- polietilenska folija (1000 kg/m3), preklopi od 20 cm; postavlja se u funkciji razdjelnog sloja i parne brane u vidu sprječavanja prodora kondenzata / vlage prema slojevima poda s podnim grijanjem, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

5 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- armiranobetonska stropna/podna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

22 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - ploče ekstrudiranog polistirena XPS (cca 40 kg/m3); (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,033 W/mK, Klasa gorivosti po HRN EN 13501-1: E)

5 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 18

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- varena PVC hidroizolacija (1000 kg/m3); poput: Sika (Sikaplan WP 1100-15 HL) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E) ili hidroizolacija TPO/FPO membrana (1000 kg/m3); poput: Sika (Sikaplan WT 1200-16, FPO-PE) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E)

0,15 – 0,2 cm

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- donja betonska podloga, armirana i zaglađena (2500 kg/m3) zaglađene gornje površine pogodne za postavu odabrane hidroizolacije, sve prema uputama proizvođača hidroizolacije (Klasa gorivosti po HRN EN 13501-1: A1)

cca 10 cm

- polietilenska folija (1000 kg/m3), prema potrebi (Klasa gorivosti po HRN EN 13501-1: E) 0,02 cm - nabijeno tlo / zamjenski kameni agregat (ovisno o terenu) / nasip dobro nabijene batude (dobro nabijena u dva sloja) ≥ 20 cm

-

U = 0,26 W/m2K < 0,40 W/m2K U = 0,26 W/m2K < 0,30 W/m2K – podno grijanje ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. Međukatne konstrukcije : Kod svih "plivajućih podova" gornja ploča iznad mekoelastičnog sloja elastificiranog ekspandiranog polistirena (EPS-T) mora biti bočno odijeljena od zidova vertikalnom trakom EPS-a debljine 1 cm; gornji slojevi su "plivajući"; PE foliju podignuti vertikalno uz rubove. ZPS3: kod izvedbe podnih konstrukcija toplinska izolacija može biti razreda reakcije na požar E, uz uvjet da je nosiva podna konstrukcija razreda reakcije na požar A2 propisane otpornosti na požar (armiranobetonska ploča), te da se iznad toplinske izolacije nalazi sloj materijala od najmanje 5 cm debljine razreda reakcije na požar A2 (cementna glazura i sl.), odnosno da ne postoji mogućnost izravnog prijenosa požara na toplinsku izolaciju, prema mišljenju Ministarstva unutarnjih poslova, Uprava za upravne i inspekcijske poslove, Sektor za inspekcijske poslove, Zagreb (Mišljenje, Klasa: 214-02/18-21/4, Urbroj: 511-01-208-18-2 od 18. siječnja 2018. godine). OPASKA: Kao akustička obloga predlaže se perforirana drvena obloga TOPAKUSTIK ploče GR 28/4 32/16 (drvo) odmaknute od podloge + 5cm mineralne vune (sve prema specifikacijama proizvođača). Parametri u proračunu za izabrane perforirane ploče: mHz 125 250 500 1000 2000 4000

α 0,45 0,85 0,65 0,60 0,45 0,45

ili perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE 12/25 Q – ploče s akustičkim voalom (standardno crne boje) (koji zamjenjuje u smislu zvučne izolacije 5 cm mineralne vune) + 5 cm mineralne vune (u podgledu stropa, odnosno obloge zida). Akustik ploče treba montirati na odmaku od podloge (krova) cca 200 mm, dok su ploče od zida odmaknute cca 50 mm ili više. Sloj zraka između podloge i akustičke obloge je ventiliran unutarnjim zrakom kako bi se spriječila neželjena kondenzacija. Perforirana površina gore navedenih ploča je cca 18,1 %. Akustik ploče – zid, odmak cca 50mm: mHz 125 250 500 1000 2000 4000

α 0,10 0,34 0,69 0,88 0,78 0,64 Akustik ploče – strop, odmak cca 200mm: mHz 125 250 500 1000 2000 4000

α 0,58 0,92 0,99 0,86 0,84 0,64

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 19

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

M1 Međukatna konstrukcija između grijanih prostora – pod dvorane za ergonomiju - završna hodna obloga – poliuretan / PVC cca 0,4 cm - OSB ploče (650 kg/m3), QSB ploče ili šperploče, nosivu hodnu konstrukciju potrebno izvesti ravno, bez pukotina i sl. radi postave završne hodne obloge (obavezno odabrati završnu oblogu s Klasom gorivosti po HRN EN 13501-1: D)

1,8 – 2,4 cm

- dvostruki drveni nosači na elastičnim podlošcima, zračni prostor između; drvena potkonstrukcija nosača nosive hodne obloge poda – roštilj specijalnih savitljivih drvenih gredica (u dva smjera) na gumenim podlošcima (zvučna zaštita od udarnog zvuka i elasticitet poda)

≥ 3,5 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 10 cm; postavlja se u funkciji razdjelnog sloja i parne brane u vidu sprječavanja prodora kondenzata / vlage prema slojevima sportskog poda

0,02 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

1 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- armiranobetonska stropna/podna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

22 cm

- elastično ovješena potkonstrukcija limenih profila (CD 60x27) + neventilirani zračni prostor između potkonstrukcije (podkonstrukcija spuštenog stropa mora imati reakciju na požar A2 za ZPS3)

≥ 5 cm

- spušteni strop na elastično ovješenoj metalnoj potkonstrukciji, gipskartonske ploče (700-825 kg/m3) na metalnoj potkonstrukciji, 1 x 12,5 mm ili 2 x 12,5 mm; obične (Knauf ploča A 13) ili vodootporne prema potrebama prostora u kojem se nalaze (Knauf ploča H2 13) ili vatrootporne prema mjerama zaštite od požara (Knauf ploča DF 13) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0); (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,25 cm

"Sportski pod" od proizvođača kao "HARO Sport Flooring" tipa London 10, sve izvedeno prema uputama proizvođača. Debljina sportskog poda je 5-7cm. U = 0,54 W/m2K ZPS3: minimalna dopuštena reakcija na požar za konstrukcije ispod neobrađene stropne ploče uključujući i pričvršćenja izuzev stropne obloge, je za klasificirani sustav D-d0, dok je za stropne obloge na evakuacijskim putevima C-s1, d0 za hodnike i za stubišta. ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. OPASKA: U višenamjenskim učionicama i prostorijama za edukaciju u podgledu stropa umjesto gore navedenog stropa je predviđeni spušteni strop sa akustičkim pločama i mineralna vuna u međuprostoru:

- elastično ovješena potkonstrukcija limenih profila (CD 60x27) + neventilirani zračni prostor između potkonstrukcije (podkonstrukcija spuštenog stropa mora imati reakciju na požar A2 za ZPS3) + mineralna vuna između potkronstrukcije debljine min.5cm kao Knauf Insulation ECOSE filc DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal

≥ 5 cm

- spušteni strop na elastično ovješenoj metalnoj potkonstrukciji – akustičke ploče, perforirana drvena obloga kao TOPAKUSTIK ploče GR 28/4 32/16 (drvo) odmaknute od podloge (+ 5cm mineralne vune - gore opisana) (sve prema specifikacijama proizvođača)

≥ 1,25 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 20

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

ili perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE 12/25 Q – ploče s akustičkim voalom (standardno crne boje) ili jednakovrijedan materijal (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

M2 Međukatna konstrukcija grijanih prostora iznad otvorenog– pod dvorane za ergonomiju

- završna hodna obloga – poliuretan / PVC cca 0,4 cm - OSB ploče (650 kg/m3), QSB ploče ili šperploče, nosivu hodnu konstrukciju potrebno izvesti ravno, bez pukotina i sl. radi postave završne hodne obloge (obavezno odabrati završnu oblogu s Klasom gorivosti po HRN EN 13501-1: D)

1,8 – 2,4 cm

- dvostruki drveni nosači na elastičnim podlošcima, zračni prostor između; drvena potkonstrukcija nosača nosive hodne obloge poda – roštilj specijalnih savitljivih drvenih gredica (u dva smjera) na gumenim podlošcima (zvučna zaštita od udarnog zvuka i elasticitet poda)

≥ 3,5 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 10 cm; postavlja se u funkciji razdjelnog sloja i parne brane u vidu sprječavanja prodora kondenzata / vlage prema slojevima sportskog poda

0,02 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E)

1 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- armiranobetonska stropna/podna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

22 cm

- mineralna vuna s površinskom obradom za ventilirana pročelja - kao Knauf Insulation ploča za ventilirane fasade s crnim voalom NaturBoard Venti GVB ili NaturBoard Ventacusto GVB (50-70 kg/m3) ili jednakovrijedan materijal (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK ili λD = 0,034 W/mK, Klasa gorivosti po HRN EN 13501-1: A1)

16 cm

- ventilirani sloj zraka i podkonstrukcija nosača obloge podgleda, otvori zaštićeni mrežicama ≥ 4 cm - završna obloga ventiliranog pročelja (obloga trespom), na ovješenoj metalnoj podkonstrukciji; preporuča se odabrati klasificirani sustav ventiliranog pročelja s najmanjom dopuštenom reakcijom na požar od D-d1 za ZPS3

≥ 0,8 cm

"Sportski pod" od proizvođača kao "HARO Sport Flooring" tipa London 10, sve izvedeno prema uputama proizvođača. Debljina sportskog poda je 5-7cm. U = 0,16 W/m2K < 0,25 W/m2K ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski sustav ventiliranog pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za vanjski sloj D, za izolacijski sloj D, za podkonstrukciju D – štapasta ili A2 - točkasta, što gore navedeni sustav zadovoljava. M3 Međukatna konstrukcija između grijanih prostora (hodnik)

- završna hodna obloga – ovisno o namjeni prostora: poliuretanski lijevani pod, lijepljene protuklizne gres keramičke pločice / gres stoneware (lijepljene fleksibilnim građevinskim

≥ 0,5 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 21

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

ljepilom prema uputama za lijepljenje) ili jednakovrijedan materijal, izvedba sa svim potrebnim predradnjama i prema uputama proizvođača odabranog materijala (podna obloga na evakuacijskim putevima ima reakciju na požar najmanje Cfl-s1 za ZPS3) - lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E) – postavljanje u toj debljini radi niveliranja kota gotovog poda različitih prostorija

5 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge)

2 cm

- armiranobetonska stropna/podna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

22 cm

- elastično ovješena potkonstrukcija limenih profila (CD 60x27) + neventilirani zračni prostor između potkonstrukcije (podkonstrukcija spuštenog stropa mora imati reakciju na požar A2 za ZPS3)

≥ 5 cm

- spušteni strop na elastično ovješenoj metalnoj potkonstrukciji, gipskartonske ploče (700-825 kg/m3) na metalnoj potkonstrukciji, 1 x 12,5 mm ili 2 x 12,5 mm; obične (Knauf ploča A 13) ili vodootporne prema potrebama prostora u kojem se nalaze (Knauf ploča H2 13) ili vatrootporne prema mjerama zaštite od požara (Knauf ploča DF 13) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0); (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,25 cm

U = 0,39 W/m2K ZPS3: minimalna dopuštena reakcija na požar za konstrukcije ispod neobrađene stropne ploče uključujući i pričvršćenja izuzev stropne obloge, je za klasificirani sustav D-d0, dok je za stropne obloge na evakuacijskim putevima C-s1, d0 za hodnike i za stubišta. ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. M4 Međukatna konstrukcija u sanitarijama između grijanih prostora

- završna hodna obloga - lijepljene protuklizne keramičke pločice, lijepljene protuklizne gres porculanske pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje na navedenoj hidroizolaciji), sve izvedeno prema uputama za izvedbu odabrane završne obrade poda (Klasa gorivosti po HRN EN 13501-1: A1)

≥ 1 cm

- visoko elastični cementni mort za HI u vlažnim prostorijama, d=2-4 mm, hidroizolacija tipa kao Mapelastic + mrežica Mapenet 150 ili Sikalastic 152 ili neki drugi hidroizolacijski elastični premaz istih karakteristika (jednakovrijedan materijal), izvedba prema smjernicama proizvođača (Klasa gorivosti po HRN EN 13501-1 za Sikalastic 152: C-s1, d0)

0,2 – 0,4 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E) – postavljanje u toj debljini radi niveliranja kota gotovog poda različitih prostorija

5 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E) + elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog

2 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 22

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge) - armiranobetonska stropna/podna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

22 cm

- elastično ovješena potkonstrukcija limenih profila (CD 60x27) + neventilirani zračni prostor između potkonstrukcije (podkonstrukcija spuštenog stropa mora imati reakciju na požar A2 za ZPS3)

≥ 5 cm

- spušteni strop na elastično ovješenoj metalnoj potkonstrukciji, gipskartonske ploče (700-825 kg/m3) na metalnoj potkonstrukciji, 1 x 12,5 mm ili 2 x 12,5 mm; obične (Knauf ploča A 13) ili vodootporne prema potrebama prostora u kojem se nalaze (Knauf ploča H2 13) ili vatrootporne prema mjerama zaštite od požara (Knauf ploča DF 13) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0); (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,25 cm

U = 0,39 W/m2K ZPS3: minimalna dopuštena reakcija na požar za konstrukcije ispod neobrađene stropne ploče uključujući i pričvršćenja izuzev stropne obloge, je za klasificirani sustav D-d0, dok je za stropne obloge na evakuacijskim putevima C-s1, d0 za hodnike i za stubišta. ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. M5 Međukatna konstrukcija stubišta – kraka

- završna hodna obloga - lijepljene protuklizne keramičke pločice, lijepljene protuklizne gres porculanske pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom), sve izvedeno prema uputama za izvedbu odabrane završne obrade poda (Klasa gorivosti po HRN EN 13501-1: A1) (podna obloga na evakuacijskim putevima ima reakciju na požar najmanje Cfl-s1 za ZPS3)

1 - 1,5 cm

- armiranobetonska kosa ploča stubišta (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

> 16 cm

- cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden podgled stropne ploče (Klasa gorivosti po HRN EN 13501-1: A1); (završna stropna obloga na evakuacijskim putevima mora imati reakciju na požar najmanje C-s1, d0 za ZPS3)

0,5 - 2 cm

Stubišni krakovi predviđaju se u izvedbi dilatirani od obodnih zidova, vezani samo na podeste. Za završnu oblogu stropova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. ZPS3: minimalna dopuštena reakcija na požar za stropne obloge na evakuacijskim putevima je za hodnike i stubišta C-s1, d0, što gore navedeni sustav zadovoljava. M6 Međukatna konstrukcija grijanog prostora na katu iznad negrijane prostorije prizemlja

- završna hodna obloga – ovisno o namjeni prostora: poliuretanski lijevani pod, lijepljene protuklizne gres keramičke pločice / gres stoneware (lijepljene fleksibilnim građevinskim ljepilom prema uputama za lijepljenje) ili jednakovrijedan materijal, izvedba sa svim potrebnim predradnjama i prema uputama proizvođača odabranog materijala (podna obloga na evakuacijskim putevima ima reakciju na požar najmanje Cfl-s1 za ZPS3)

≥ 0,5 cm

- lagano armirana betonska podloga zaglađena (2200 kg/m3); cementna glazura sa staklenim nitima za armiranje (Klasa gorivosti po HRN EN 13501-1: A1), cca d = 6 cm

≥ 4 cm

- polietilenska folija (1000 kg/m3) (Klasa gorivosti po HRN EN 13501-1: E), preklopi od 20 cm; razdjelni sloj, polietilenska (PE) folija se povlači i uz bočne zidove do završne visine cementne glazure

0,02 cm

- ploče ekspandiranog polistirena EPS 100 ili EPS 150 (25 kg/m3) (deklarirana toplinska provodljivost po HRN EN 12667: min. λD = 0,036 W/mK ili bolje, Klasa gorivosti po HRN EN 13501-1: E) – postavljanje u toj debljini radi niveliranja kota gotovog poda različitih prostorija

5 cm

- elastificirani ekspandirani polistiren EPS – T (15 kg/m3) u dva sloja (2x1 cm) (Klasa gorivosti po HRN EN 13501-1: E)

2 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 23

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

+ elastificirani ekspandirani polistiren na spoju poda sa zidom (rubno uza zid) debljine 10 mm ili jednakovrijedno; područje dodira podnog sustava potrebno je trakom iz elastificiranog ekspandiranog polistirena do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge) - armiranobetonska stropna/podna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

22 cm

- klasificirani ETICS sustav sa toplinskom izolacijom od MW (Klasa gorivosti cijelog klasificiranog ETICS sustava s MW po HRN EN 13501-1: A2-s1, d0) koji se sastoji od: + ploče mineralne vune za ETICS fasade - kao Knauf Insulation ploča za kontaktne fasade FKD S Thermal (115 kg/m3) ili jednakovrijedan materijal, dodatno učvršćen građevinskim ljepilom i plastičnim pričvrsnicama sa širokom glavom na podlogu (min. 6-8 kom/m2) (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK) + polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom (1800 kg/m3) sa odgovarajućom završnom fasadnom (silikatnom) žbukom, prema uputama proizvođača odabranog fasadnog sustava ili jednakovrijedan materijal

5 cm + cca 0,5 cm

U = 0,26 W/m2K < 0,40 W/m2K Za završnu oblogu stropova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama ZPS3: minimalna dopuštena reakcija na požar za završnu podnu oblogu na evakuacijskim putevima (hodnik i stubište) je Cfl-s1, što gore navedeni sustav zadovoljava. ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski kontaktni sustav pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za pokrovni sloj D, za izolacijski sloj C, što gore navedeni sustav zadovoljava. Krovovi : K1 Ravni zeleni laki krov dvorane za ergonomiju

- biljni sloj kao SEDUM MIX – 100% gusto prorašteni sedum tepih na kokosovoj prostirci - - supstrat za ekstenzivne zelene krovove (mješavina mineralnih sastojaka odgovarajuće granulacije i tresetno – humusnog dodatka) – kao HUMOKOMPOVIT H6 R ili jednakovrijedan materijal; debljina supstrata 10cm - 12 cm

10 - 12 cm

- prostirka za retenciju vode od kamene vune bez veziva, kao URBANSCAPE GREEN ROLL ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A1)

2 cm

- filterski sloj (kao tipa FIBRAN SF32 ili jednakovrijedan materijal), netkani polipropilenski geotekstil termički vezanih vlakana (Klasa gorivosti po HRN EN 13501-1: E)

-

- drenažno akumulacijske ploče – EPS kadice; kao KEMPOR ZK60 ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E)

6 cm

- zaštitni sloj (kao FIBRAN skin SEAL ili jednakovrijedan materijal), difuzno otvorena membrana za bržu odvodnju vode (Klasa gorivosti po HRN EN 13501-1: E)

-

- ploče ekstrudiranog polistirena XPS (cca 40 kg/m3); (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,033 W/mK, Klasa gorivosti po HRN EN 13501-1: E), kao FIBRAN XPS 300 L, d=50mm ili jednakovrijedan materijal, kao mehanička zaštita hidroizolacije

5 cm

- razdjelni sloj, filc od netkanog staklenog voala (300-500 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- sintetička krovna hidroizolacijska membrana za balastne prohodne, neprohodne i zelene krovove na bazi TPO; jednoslojna hidroizolacijska membrana od sintetičke gume (FPO/TPO) ojačana staklenim voalom (1200 – 1600 kg/m3) – kao Sarnafil TG66, Bauder Thermolin 018 ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E) potrebno je da odabrana hidroizolacija otporna na korijenje; izvedba sve prema uputama proizvođača odabranog sustava hidroizolacije, toplinske izolacije i slojeva zelenog krova

0,18 cm

- tvrde ploče mineralne vune - kao Knauf Insulation ploča za ravne krovove SMARTROOF TOP ili jednakovrijedan materijal, ploče polagane po slojevima na ravnoj armiranobetonskoj

10 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 24

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

ploči (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1) - tvrde ploče mineralne vune - kao Knauf Insulation ploča za ravne krovove SMARTROOF THERMAL ili jednakovrijedan materijal, ploče polagane po slojevima na ravnoj armiranobetonskoj ploči (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,036 W/mK, Klasa gorivosti po HRN EN 13501-1: A1)

15 cm

- parna brana – kao Sarnavap 1000 E (polietilenska parna brana, obavezno sa ljepljenjem preklopa i uz rubna ljepljenja) ili Knauf Insulation HOMESEAL LDS 100 AluPlus parna brana (90 g/m2) ili jednakovrijedan materijal, postava parne brane u svemu prema uputama proizvođača (moguće ih je zabrtviti i ljepljivim trakama kao Soliplan i Solifit) (Klasa gorivosti po HRN EN 13501-1: E)

0,02 – 0,4 cm

- čelični trapezni profilirani lim, samonosivi, visine 155 mm + neventilirani zračni sloj

0,1 cm

- čelična krovna konstrukcija nosača IPE 550, L60/60/6 i HEA 120, sve prema statičkom proračunu, zaštićeno protupožarnim premazom

cca 73 cm

- elastično ovješena potkonstrukcija limenih profila (CD 60x27) + neventilirani zračni prostor između potkonstrukcije (podkonstrukcija spuštenog stropa mora imati reakciju na požar A2 za ZPS3) + mineralna vuna između potkronstrukcije debljine min.5cm kao Knauf Insulation ECOSE filc DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal

≥ 5 cm

- spušteni strop na elastično ovješenoj metalnoj potkonstrukciji – akustičke ploče, perforirana drvena obloga kao TOPAKUSTIK ploče GR 28/4 32/16 (drvo) odmaknute od podloge (+ 5cm mineralne vune - gore opisana) (sve prema specifikacijama proizvođača) ili perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE 12/25 Q – ploče s akustičkim voalom (standardno crne boje) ili jednakovrijedan materijal (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,25 cm

U = 0,10 W/m2K < 0,25 W/m2K Za završnu oblogu stropova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. Slojeve zelenog ravnog krova tipa URBANSCAPE ekstenzivni zeleni krov potrebno je izvesti prema uputama proizvođača. ZPS3: minimalna dopuštena reakcija na požar za konstrukcije ispod neobrađene stropne ploče uključujući i pričvršćenja izuzev stropne obloge, je za klasificirani sustav D-d0, dok je za stropne obloge na evakuacijskim putevima C-s1, d0 za hodnike i za stubišta. ZPS3: minimalna dopuštena reakcija na požar za ravni krov je za pokrov = Bkrov (t1), za toplinsku izolaciju = E, sve postavljeno na negorivu podlogu (trapezni lim), što gore navedeni sustav zadovoljava. K2 Ravni neprohodni krov

- zaštitni sloj oblutaka 16-32 min. 8 cm - razdjelni sloj, filc od netkanog staklenog voala (300-500 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- sintetička krovna hidroizolacijska membrana za balastne prohodne, neprohodne i zelene krovove na bazi TPO; jednoslojna hidroizolacijska membrana od sintetičke gume (FPO/TPO) ojačana staklenim voalom (1200 – 1600 kg/m3) – kao Sarnafil TG66 ili sintetička krovna hidroizolacijska membrana za balastne prohodne, neprohodne i zelene krovove na bazi PVC-a (1200 – 1600 kg/m3) – kao Sikaplan SGmA -15 ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E) izvedba sve prema uputama proizvođača odabranog sustava hidroizolacije i toplinske izolacije, obavezno brtvljenje svih prodora kroz hidroizolaciju

0,15 – 0,2 cm

- razdjelni sloj, filc od netkanog staklenog voala (300-500 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 25

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- ploče ekstrudiranog polistirena XPS (cca 40 kg/m3); ploče polagane po slojevima na ravnoj armiranobetonskoj ploči; debljine 15cm+15cm (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,033 W/mK, Klasa gorivosti po HRN EN 13501-1: E)

30 cm

- parna brana s uloškom alu-folije (950 kg/m3) ili Sika BituSeal T-230 PA (punoplošno lijepljena) ili kao Knauf Insulation LDS parna brana ili jednakovrijedan materijal, sve prema uputama proizvođača odabranog sustava toplinske izolacije i hidroizolacije (Klasa gorivosti po HRN EN 13501-1: E)

0,02 – 0,4 cm

- sloj za izjednačenje, sintetički voal (Klasa gorivosti po HRN EN 13501-1: E) prema potrebi (kod parnih brana koje nisu punoplošno lijepljene)

-

- lagani beton u nagibu (cca 1000 – 1500 kg/m3) (Klasa gorivosti po HRN DIN 4102-1: A1); u padu ≥ 1,5 % prema slivnicima

≥ 4 cm

- armiranobetonska stropna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

16 cm

- cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden podgled stropne ploče (Klasa gorivosti po HRN EN 13501-1: A1); (završna stropna obloga na evakuacijskim putevima mora imati reakciju na požar najmanje C-s1, d0 za ZPS3)

0,5 - 2 cm

U = 0,11 W/m2K < 0,25 W/m2K Za završnu oblogu stropova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama ZPS3: minimalna dopuštena reakcija na požar za ravni krov sa gornjim slojem od minimalno 5cm šljunka ili istovjetnog materijala je za hidroizolaciju E, a za toplinsku izolaciju položenu na armiranobetonsku ploču odnosno negorivu podlogu D, što gore navedeni sustav zadovoljava, prema mišljenju Ministarstva unutarnjih poslova, Uprava za upravne i inspekcijske poslove, Sektor za inspekcijske poslove, Zagreb (Mišljenju o mogućnosti primjene gorivih toplinskih izolacija obloženih negorivim materijalima, Klasa: 214-02/17-14/60, Urbroj: 511-01-208-17-2 od 20. lipnja 2017. godine). ZPS3: minimalna dopuštena reakcija na požar za stropne obloge na evakuacijskim putevima je za hodnike i stubišta C-s1, d0, što gore navedeni sustav zadovoljava. Konstrukcija istake iz obodnih konstrukcija grijanih prostora prema otvorenom odnosno negrijanom prostoru (toplinski mostovi - istake iz zidova ili stropnih ploča) mora biti obostrano prevučena slojem toplinske izolacije minimalne debljine 8 cm s odgovarajućim završnim slojem, u duljini minimalno 100 cm od kontakta izolirane površine i istake, kako bi se produljili toplinski mostovi. Vidi rješenja toplinskih mostova u Katalogu dobro riješenih toplinskih mostova na zgradama – prilog D Tehničkog propisa (NN 128/2015). K2a Ravni neprohodni krov, smještaj strojarskih uređaja – podnožja uređaja i opreme

- završni premaz bojom za beton, završni sloj od zaglađenog kremenog pijeska ili sl.; gornja površina obrađena kao tzv.češka glazura

-

- armiranobetonska podloga zaglađena, dilatirana (2200 kg/m3) (Klasa gorivosti po HRN DIN 4102-1: A1)

≥ 12 cm

- folija od ekstrudiranog polietilena u dva sloja - Dow Chemical Ethafoam 222-E u dva sloja (2x0,5 cm) ili jednakovrijedan materijal, postiže ΔLw = 25 dB u dva sloja u plivajućem podu, foliju obavezno dignuti rubno uza zid (na spoju poda sa zidom); područje dodira podnog sustava potrebno je trakom folije do visine gotovog poda odvojiti/dilatirati od bočnih zidova (ukoliko postoje); postavlja se prije početka ugradnje cementne glazure (lagano armirane betonske podloge) (Klasa gorivosti po HRN EN 13501-1: E)

1 cm

- razdjelni sloj, filc od netkanog staklenog voala (300-500 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- sintetička krovna hidroizolacijska membrana za balastne prohodne, neprohodne i zelene krovove na bazi TPO; jednoslojna hidroizolacijska membrana od sintetičke gume (FPO/TPO) ojačana staklenim voalom (1200 – 1600 kg/m3) – kao Sarnafil TG66 ili sintetička krovna hidroizolacijska membrana za balastne prohodne, neprohodne i zelene krovove na bazi PVC-a (1200 – 1600 kg/m3) – kao Sikaplan SGmA -15 ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E) izvedba sve prema uputama proizvođača odabranog sustava hidroizolacije i toplinske izolacije, obavezno brtvljenje svih prodora kroz hidroizolaciju

0,15 – 0,2 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 26

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- razdjelni sloj, filc od netkanog staklenog voala (300-500 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- ploče ekstrudiranog polistirena XPS (cca 40 kg/m3); ploče polagane po slojevima na ravnoj armiranobetonskoj ploči; debljine 15cm+15cm (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,033 W/mK, Klasa gorivosti po HRN EN 13501-1: E)

30 cm

- parna brana s uloškom alu-folije (950 kg/m3) ili Sika BituSeal T-230 PA (punoplošno lijepljena) ili kao Knauf Insulation LDS parna brana ili jednakovrijedan materijal, sve prema uputama proizvođača odabranog sustava toplinske izolacije i hidroizolacije (Klasa gorivosti po HRN EN 13501-1: E)

0,02 – 0,4 cm

- sloj za izjednačenje, sintetički voal (Klasa gorivosti po HRN EN 13501-1: E) prema potrebi (kod parnih brana koje nisu punoplošno lijepljene)

-

- lagani beton u nagibu (cca 1000 – 1500 kg/m3) (Klasa gorivosti po HRN DIN 4102-1: A1); u padu ≥ 1,5 % prema slivnicima

≥ 4 cm

- armiranobetonska stropna ploča (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1)

16 cm

- cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden podgled stropne ploče (Klasa gorivosti po HRN EN 13501-1: A1); (završna stropna obloga na evakuacijskim putevima mora imati reakciju na požar najmanje C-s1, d0 za ZPS3)

0,5 - 2 cm

U = 0,11 W/m2K < 0,25 W/m2K Za završnu oblogu stropova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama ZPS3: minimalna dopuštena reakcija na požar za ravni krov sa gornjim slojem od minimalno 5cm šljunka ili istovjetnog materijala je za hidroizolaciju E, a za toplinsku izolaciju položenu na armiranobetonsku ploču odnosno negorivu podlogu D, što gore navedeni sustav zadovoljava, prema mišljenju Ministarstva unutarnjih poslova, Uprava za upravne i inspekcijske poslove, Sektor za inspekcijske poslove, Zagreb (Mišljenju o mogućnosti primjene gorivih toplinskih izolacija obloženih negorivim materijalima, Klasa: 214-02/17-14/60, Urbroj: 511-01-208-17-2 od 20. lipnja 2017. godine). ZPS3: minimalna dopuštena reakcija na požar za stropne obloge na evakuacijskim putevima je za hodnike i stubišta C-s1, d0, što gore navedeni sustav zadovoljava. Konstrukcija istake iz obodnih konstrukcija grijanih prostora prema otvorenom odnosno negrijanom prostoru (toplinski mostovi - istake iz zidova ili stropnih ploča) mora biti obostrano prevučena slojem toplinske izolacije minimalne debljine 8 cm s odgovarajućim završnim slojem, u duljini minimalno 100 cm od kontakta izolirane površine i istake, kako bi se produljili toplinski mostovi. Vidi rješenja toplinskih mostova u Katalogu dobro riješenih toplinskih mostova na zgradama – prilog D Tehničkog propisa (NN 128/2015). Zidovi prema tlu: Napomena: Na radnim reškama i spojevima armiranobetonskih konstrukcija izvesti brtvenu hidroizolacijsku traku (gdje god je to tehnički moguće izvesti). ZPS3: minimalna dopuštena reakcija na požar za završne unutarnje obrade zida u evakuacijskim putevima su za klasificirani sustav C, dok je na evakuacijskim putevima završni sloj zida C-s1, d0 za hodnike i stubišta, što gore navedeni sustav zadovoljava. ZPS3: minimalna dopuštena reakcija na požar za unutarnje obloge zida (izuzev evakuacijskih puteva) su za klasificirani sustav D, odnosno za zidnu oblogu D i izolaciju C. PZ1 Zid prema tlu grijanog i negrijanog prostora (prizemlje)

- cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden armiranobetonski zid (Klasa gorivosti po HRN EN 13501-1: A1)

0,5 - 2 cm

- armirani beton (2500 kg/m3) u glatkoj oplati (Klasa gorivosti po HRN EN 13501-1: A1) 30 cm - hidroizolacija TPO/FPO membrana (1000 kg/m3); poput: Sika (Sikaplan WT 1200-16, FPO-PE) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E) ili varena PVC hidroizolacija (1000 kg/m3); poput: Sika (Sikaplan WP 1100-15 HL) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E)

0,15 – 0,2 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 27

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- razdjelni sloj, filc od netkanog staklenog voala (150-300 g/m2) – geotekstil, termički obrađen PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača odabrane hidroizolacije

-

- ploče ekstrudiranog polistirena XPS (cca 40 kg/m3); (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,033 W/mK, Klasa gorivosti po HRN EN 13501-1: E)

12 cm

- čepasta drenažna traka – tefond (670 g/m2), zaštita hidroizolacije i termoizolacije, visine čepića cca 0,8 - 1,2 cm (Klasa gorivosti po HRN EN 13501-1: E)

0,06 cm

- drenažni krupni šljunak (1700 kg/m3) cca 30 cm - tlo -

U = 0,26 W/m2K < 0,40 W/m2K Na tako izvedenu nosivu / pregradnu stijenu, ovisno o prostoru u kojem se nalazi, prema potrebi se u unutarnji prostor postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). Za završnu oblogu zidova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. Vanjski zidovi : ZPS3: Ukoliko se radi o neklasificiranom sustavu pročelja toplinska izolacija pročelja može biti razreda reakcije na požar i E kategorije, ali samo u zoni podnožja i područja prskanja vodom u visini do 50 cm od uređenog tla ili druge negorive završne obloge podloge, te u slučajevima kada je toplinska izolacija zatrpana (zasuta) negorivim materijalom, prema mišljenju Ministarstva unutarnjih poslova, Uprava za upravne i inspekcijske poslove, Sektor za inspekcijske poslove, Zagreb (Mišljenju o mogućnosti primjene gorivih toplinskih izolacija obloženih negorivim materijalima, Klasa: 214-02/17-14/60, Urbroj: 511-01-208-17-2 od 20. lipnja 2017. godine). ZPS3: minimalna dopuštena reakcija na požar za završne unutarnje obrade zida u evakuacijskim putevima su za klasificirani sustav C, dok je na evakuacijskim putevima završni sloj zida C-s1, d0 za hodnike i stubišta, što gore navedeni sustav zadovoljava. ZPS3: minimalna dopuštena reakcija na požar za unutarnje obloge zida (izuzev evakuacijskih puteva) su za klasificirani sustav D, odnosno za zidnu oblogu D i izolaciju C. Z1 Vanjski ventilirani zid u prizemlju

- cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden armiranobetonski zid (Klasa gorivosti po HRN EN 13501-1: A1)

0,5 - 2 cm

- armirani beton (2500 kg/m3) (Klasa gorivosti po HRN EN 13501-1: A1), debljine 25 ili 30 cm 25 cm - mineralna vuna s površinskom obradom za ventilirana pročelja - kao Knauf Insulation ploča za ventilirane fasade s crnim voalom NaturBoard Venti GVB ili NaturBoard Ventacusto GVB (50-70 kg/m3) ili jednakovrijedan materijal (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK ili λD = 0,034 W/mK, Klasa gorivosti po HRN EN 13501-1: A1) + podnožje zida do visine 30-50 cm iznad terena/terasa izvodi se tvrdi pločama ekstrudiranog polistirena – XPS (λD = 0,033 W/mK) u debljini od 12 cm + hidroizolacija na zidu (sokl) + polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom (1800 kg/m3) (Klasa gorivosti sustava sa XPS-om kao ETICS sustav na podnožju zida unutar ventiliranog pročelja po HRN EN 13501-1: B-s2, d0)

14 cm

- ventilirani sloj zraka i podkonstrukcija nosača obloge podgleda, otvori zaštićeni mrežicama ≥ 4 cm - završna obloga ventiliranog pročelja (obloga trespom), na ovješenoj metalnoj podkonstrukciji; preporuča se odabrati klasificirani sustav ventiliranog pročelja s najmanjom dopuštenom reakcijom na požar od D-d1 za ZPS3

≥ 0,8 cm

U = 0,23 W/m2K < 0,30 W/m2K U = 0,26 W/m2K < 0,30 W/m2K - sokl Na tako izvedenu nosivu / pregradnu stijenu, ovisno o prostoru u kojem se nalazi, prema potrebi se u unutarnji prostor postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). Za završnu oblogu zidova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski sustav ventiliranog pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za vanjski sloj D, za izolacijski sloj D, za podkonstrukciju D – štapasta ili A2 - točkasta, što gore navedeni sustav zadovoljava.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 28

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Z2 Vanjski ventilirani zid na katu - cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden armiranobetonski zid (Klasa gorivosti po HRN EN 13501-1: A1)

0,5 - 2 cm

- armirani beton (2500 kg/m3) (Klasa gorivosti po HRN EN 13501-1: A1) debljine 25 ili 30 cm 25 cm - mineralna vuna s površinskom obradom za ventilirana pročelja - kao Knauf Insulation ploča za ventilirane fasade s crnim voalom NaturBoard Venti GVB ili NaturBoard Ventacusto GVB (50-70 kg/m3) ili jednakovrijedan materijal (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK ili λD = 0,034 W/mK, Klasa gorivosti po HRN EN 13501-1: A1) + podnožje zida do visine 30-50 cm iznad terena/terasa izvodi se tvrdi pločama ekstrudiranog polistirena – XPS (λD = 0,033 W/mK) u debljini od 14 cm + hidroizolacija na zidu (sokl) + polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom (1800 kg/m3) (Klasa gorivosti sustava sa XPS-om kao ETICS sustav na podnožju zida unutar ventiliranog pročelja po HRN EN 13501-1: B-s2, d0)

16 cm

- ventilirani sloj zraka i podkonstrukcija nosača obloge podgleda, otvori zaštićeni mrežicama ≥ 4 cm - završna obloga ventiliranog pročelja (obloga trespom), na ovješenoj metalnoj podkonstrukciji; preporuča se odabrati klasificirani sustav ventiliranog pročelja s najmanjom dopuštenom reakcijom na požar od D-d1 za ZPS3

≥ 0,8 cm

U = 0,21 W/m2K < 0,30 W/m2K U = 0,22 W/m2K < 0,30 W/m2K - sokl Na tako izvedenu nosivu / pregradnu stijenu, ovisno o prostoru u kojem se nalazi, prema potrebi se u unutarnji prostor postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). Za završnu oblogu zidova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski sustav ventiliranog pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za vanjski sloj D, za izolacijski sloj D, za podkonstrukciju D – štapasta ili A2 - točkasta, što gore navedeni sustav zadovoljava. Z2a Vanjski ventilirani zid na katu – dvorana za ergonomiju

- zidna obloga na elastično ovješenoj metalnoj potkonstrukciji – akustičke ploče, perforirana drvena obloga kao TOPAKUSTIK ploče GR 28/4 32/16 (drvo) odmaknute od podloge (+ 5cm mineralne vune - niže opisana) (sve prema specifikacijama proizvođača) ili perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE 12/25 Q – ploče s akustičkim voalom (standardno crne boje) ili jednakovrijedan materijal (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,25 cm

- metalna potkonstrukcija nosača za zidnu oblogu (CW ili MW profili), elastično pričvršćena + mineralna vuna između potkronstrukcije debljine min.5cm kao Knauf Insulation ECOSE filc DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal

≥ 5 cm

- armirani beton (2500 kg/m3) (Klasa gorivosti po HRN EN 13501-1: A1) 30 cm - mineralna vuna s površinskom obradom za ventilirana pročelja - kao Knauf Insulation ploča za ventilirane fasade s crnim voalom NaturBoard Venti GVB ili NaturBoard Ventacusto GVB (50-70 kg/m3) ili jednakovrijedan materijal (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK ili λD = 0,034 W/mK, Klasa gorivosti po HRN EN 13501-1: A1)

16 cm

- ventilirani sloj zraka i podkonstrukcija nosača obloge podgleda, otvori zaštićeni mrežicama ≥ 4 cm - završna obloga ventiliranog pročelja (obloga trespom), na ovješenoj metalnoj podkonstrukciji; preporuča se odabrati klasificirani sustav ventiliranog pročelja s najmanjom dopuštenom reakcijom na požar od D-d1 za ZPS3

≥ 0,8 cm

U = 0,16 W/m2K < 0,30 W/m2K ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski sustav ventiliranog pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za vanjski sloj D, za izolacijski sloj D, za podkonstrukciju D – štapasta ili A2 - točkasta, što gore navedeni sustav zadovoljava. ZPS3: minimalna dopuštena reakcija na požar za unutarnje obloge zida (izuzev evakuacijskih puteva) su za klasificirani sustav D, odnosno za zidnu oblogu D i izolaciju C, što gore navedeni sustav zadovoljava.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 29

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Z2b Vanjski ventilirani zid na katu – dio uz sanitarije - gipskartonske ploče (700-825 kg/m3) na metalnoj potkonstrukciji, 2 x 12,5 mm; vodootporne prema potrebama prostora u kojem se nalaze (Knauf ploča H2 13) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0)

2,5 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima - kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne obloge je 5 cm

5 cm

- gipskartonske ploče (700-825 kg/m3) na metalnoj potkonstrukciji, min.1 x 12,5 mm; obične (Knauf ploča A 13) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0)

≥ 1,25 cm

- neprovjetravani zračni sloj – zračni prostor u koji ulazi klizna stijena koja odvaja dio spojnog hodnika prema školi

10 cm

- armirani beton (2500 kg/m3) (Klasa gorivosti po HRN EN 13501-1: A1) 20 cm - mineralna vuna s površinskom obradom za ventilirana pročelja - kao Knauf Insulation ploča za ventilirane fasade s crnim voalom NaturBoard Venti GVB ili NaturBoard Ventacusto GVB (50-70 kg/m3) ili jednakovrijedan materijal (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK ili λD = 0,034 W/mK, Klasa gorivosti po HRN EN 13501-1: A1) + podnožje zida do visine 30-50 cm iznad terena/terasa izvodi se tvrdi pločama ekstrudiranog polistirena – XPS (λD = 0,033 W/mK) u debljini od 14 cm + hidroizolacija na zidu (sokl) + polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom (1800 kg/m3) (Klasa gorivosti sustava sa XPS-om kao ETICS sustav na podnožju zida unutar ventiliranog pročelja po HRN EN 13501-1: B-s2, d0)

16 cm

- ventilirani sloj zraka i podkonstrukcija nosača obloge podgleda, otvori zaštićeni mrežicama ≥ 4 cm - završna obloga ventiliranog pročelja (obloga trespom), na ovješenoj metalnoj podkonstrukciji; preporuča se odabrati klasificirani sustav ventiliranog pročelja s najmanjom dopuštenom reakcijom na požar od D-d1 za ZPS3

≥ 0,8 cm

U = 0,15 W/m2K < 0,30 W/m2K U = 0,16 W/m2K < 0,30 W/m2K - sokl Potkonstrukcija je od čeličnih CW ili MW profila širine 5 cm i obostrano se oblaže dvostrukom oblogom od gipskartonskih ploča d= 1,25 cm gustoće cca 700-825 kg/m3 (ovisno o vrsti obložne ploče). U međuprostor se postavlja 5 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN 13162. Za završnu oblogu zidova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama, odnosno prema potrebi se postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski sustav ventiliranog pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za vanjski sloj D, za izolacijski sloj D, za podkonstrukciju D – štapasta ili A2 - točkasta, što gore navedeni sustav zadovoljava. Z3 Vanjski zid s ETICS fasadom – zapadno pročelje dvorane

- zidna obloga na elastično ovješenoj metalnoj potkonstrukciji – akustičke ploče, perforirana drvena obloga kao TOPAKUSTIK ploče GR 28/4 32/16 (drvo) odmaknute od podloge (+ 5cm mineralne vune - niže opisana) (sve prema specifikacijama proizvođača) ili perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE 12/25 Q – ploče s akustičkim voalom (standardno crne boje) ili jednakovrijedan materijal (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,6 cm

- metalna potkonstrukcija nosača za zidnu oblogu (CW ili MW profili), elastično pričvršćena + mineralna vuna između potkronstrukcije debljine min.5cm kao Knauf Insulation ECOSE filc DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal

≥ 5 cm

- armirani beton (2500 kg/m3) (Klasa gorivosti po HRN EN 13501-1: A1) 30 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 30

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- klasificirani ETICS sustav sa toplinskom izolacijom od MW (Klasa gorivosti cijelog klasificiranog ETICS sustava s MW po HRN EN 13501-1: A2-s1, d0) koji se sastoji od: + ploče mineralne vune za ETICS fasade - kao Knauf Insulation ploča za kontaktne fasade FKD S Thermal (115 kg/m3) ili jednakovrijedan materijal, dodatno učvršćen građevinskim ljepilom i plastičnim pričvrsnicama sa širokom glavom na podlogu (min. 6-8 kom/m2) (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK) + polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom (1800 kg/m3) sa odgovarajućom završnom fasadnom (silikatnom) žbukom, prema uputama proizvođača odabranog fasadnog sustava, završna obrada sokla: Teraplast-V ili jednakovrijedan materijal + podnožje zida do visine 30-50 cm iznad terena/terasa izvodi se tvrdim pločama ekstrudiranog polistirena – XPS (λD = 0,033 W/mK) u debljini od 14 cm + hidroizolacija na zidu (sokl)

16 cm + cca 0,5 cm

U = 0,16 W/m2K < 0,30 W/m2K U = 0,17 W/m2K < 0,30 W/m2K - sokl Na tako izvedenu nosivu / pregradnu stijenu, ovisno o prostoru u kojem se nalazi, prema potrebi se u unutarnji prostor postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). Za završnu oblogu zidova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski kontaktni sustav pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za pokrovni sloj D, za izolacijski sloj C, što gore navedeni sustav zadovoljava. Unutarnji zidovi : Kod pregradnih zidova između prostora koji imaju zahtjeve za zvučnom izolacijom (boravišni prostori), nije dozvoljeno smanjenje projektirane debljine zida prorezima za vođenje instalacija (vodovod, kanalizacija, vodokotlići i sl…). Sve potrebne instalacije treba voditi u dodatnom parapetnom obzidu visine min.90 cm (sanitarije), kako ne bi došlo do opadanja zvučnoizolacijskih karakteristika pregrade, te toplinskih karakteristika pregrade ukoliko se nalaze između grijanih i negrijanih/vanjskih prostora. ZPS3: minimalna dopuštena reakcija na požar za završne unutarnje obrade zida u evakuacijskim putevima su za klasificirani sustav C, dok je na evakuacijskim putevima završni sloj zida C-s1, d0 za hodnike i stubišta, što gore navedeni sustav zadovoljava. ZPS3: minimalna dopuštena reakcija na požar za unutarnje obloge zida (izuzev evakuacijskih puteva) su za klasificirani sustav D, odnosno za zidnu oblogu D i izolaciju C. OPASKA: Na unutarnjim zidovima dvorane za ergonomiju predviđa se unutarnja obloga zida sa akustičnom oblogom zida pa se predviđa da se s unutarnje strane navedenog zida postave još dodatno slijedeći slojevi (gledano iznutra prema van) – obloga zidova je akustičnog i estetskog karaktera:

- zidna obloga na elastično ovješenoj metalnoj potkonstrukciji – akustičke ploče, perforirana drvena obloga kao TOPAKUSTIK ploče GR 28/4 32/16 (drvo) odmaknute od podloge (+ 5cm mineralne vune - niže opisana) (sve prema specifikacijama proizvođača) ili perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE 12/25 Q – ploče s akustičkim voalom (standardno crne boje) ili jednakovrijedan materijal (završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,25 cm

- metalna potkonstrukcija nosača za zidnu oblogu (CW ili MW profili), elastično pričvršćena + mineralna vuna između potkronstrukcije debljine min.5cm kao Knauf Insulation ECOSE filc DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal

≥ 5 cm

ZPS3: minimalna dopuštena reakcija na požar za unutarnje obloge zida (izuzev evakuacijskih puteva) su za klasificirani sustav D, odnosno za zidnu oblogu D i izolaciju C, što gore navedeni sustav zadovoljava.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 31

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

UZ1 Nosivi unutarnji armiranobetonski zid - cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden armiranobetonski zid (Klasa gorivosti po HRN EN 13501-1: A1)

0,5 - 2 cm

- armirani beton (2500 kg/m3) (Klasa gorivosti po HRN EN 13501-1: A1) 30 cm - cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden armiranobetonski zid (Klasa gorivosti po HRN EN 13501-1: A1)

0,5 - 2 cm

U = 2,59 W/m2K Na tako izvedenu nosivu / pregradnu stijenu, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). Za završnu oblogu zidova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. UZ2 Nosivi unutarnji armiranobetonski zid grijanog prostora prema negrijanom prostoru

- cementna glet masa (2100 kg/m3) / produžna žbuka (1800 kg/m3); ovisno o tome kako je izveden armiranobetonski zid (Klasa gorivosti po HRN EN 13501-1: A1)

0,5 - 2 cm

- armirani beton (2500 kg/m3) (Klasa gorivosti po HRN EN 13501-1: A1) 30 cm - klasificirani ETICS sustav sa toplinskom izolacijom od MW (Klasa gorivosti cijelog klasificiranog ETICS sustava s MW po HRN EN 13501-1: A2-s1, d0) koji se sastoji od: + ploče mineralne vune za ETICS fasade - kao Knauf Insulation ploča za kontaktne fasade FKD S Thermal (115 kg/m3) ili jednakovrijedan materijal, dodatno učvršćen građevinskim ljepilom i plastičnim pričvrsnicama sa širokom glavom na podlogu (min. 6-8 kom/m2) (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,035 W/mK) + polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom (1800 kg/m3) sa odgovarajućom završnom fasadnom (silikatnom) žbukom, prema uputama proizvođača odabranog fasadnog sustava ili jednakovrijedan materijal

10 cm + cca 0,5 cm

U = 0,31 W/m2K < 0,40 W/m2K Za završnu oblogu stropova (interijer) površine se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama ZPS3: minimalna dopuštena reakcija na požar za klasificirani toplinski kontaktni sustav pročelja je D-d1, odnosno (s izvedbom sa slijedećim klasificiranim komponentama) za pokrovni sloj D, za izolacijski sloj C, što gore navedeni sustav zadovoljava. UZ3 Laka pregradna stijena između grijanog i negrijanog prostora d=15,0cm (prema spremištu u

prizemlju), laka pregradna stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm; kao Knauf pregradni zid W112 Diamant pregradni zid; jednostruka podkonstrukcija + dvoslojna obloga Diamant pločama

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024 kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0); na potkonstrukciji

2,5 cm

- parna brana – kao Sarnavap 1000 E (polietilenska parna brana, obavezno sa ljepljenjem preklopa i uz rubna ljepljenja) ili Knauf Insulation HOMESEAL LDS 100 AluPlus parna brana (90 g/m2) ili jednakovrijedan materijal, postava parne brane u svemu prema uputama proizvođača (moguće ih je zabrtviti i ljepljivim trakama kao Soliplan i Solifit) (Klasa gorivosti po HRN EN 13501-1: E)

0,02 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima - kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne obloge je 10 cm

10 cm

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024 kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0); na potkonstrukciji

2,5 cm

Potkonstrukcija je od čeličnih MW ili CW profila širine 10 cm i obostrano se oblaže dvostrukom oblogom od gipskartonskih ploča tipa Diamant (protupožarna izolacija, poboljšana zvučna izolacija, vlagootpornost) d= 1,25 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 32

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

gustoće cca 1024 kg/m3. U međuprostor se postavlja 10 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN 13162. Gipskartonske ploče se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. Na tako postavljene gipskartonske ploče, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). ZVUČNA IZOLACIJA stijene W112 - Diamant pregradni zid debljine 15,0 cm JE 63 dB (A) – prema specifikacijama proizvođača. Preporuka je da se Knauf ploče spajaju klamanjem, a ne vijcima, jer se dobije još bolja zvučna izolacija izvedenih zidova. OTPORNOST NA POŽAR stijene W112 - Diamant pregradni zid debljine 15,0 cm JE EI 90 – prema specifikacijama proizvođača. U = 0,32 W/m2K < 0,40 W/m2K UZ4 Laka pregradna stijena s poboljšanim zvučnim karakteristikama d=15,0cm (između dvije

višenamjenske prostorije za edukaciju i prema drugom prostorijama, laki zid dvorane prema drugim prostorijama, zidovi kabineta), laka pregradna stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm; kao Knauf pregradni zid W112 Diamant pregradni zid; jednostruka podkonstrukcija + dvoslojna obloga Diamant pločama

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024 kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0); na potkonstrukciji

2,5 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima - kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne obloge je 10 cm

10 cm

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024 kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0); na potkonstrukciji

2,5 cm

Potkonstrukcija je od čeličnih MW ili CW profila širine 10 cm i obostrano se oblaže dvostrukom oblogom od gipskartonskih ploča tipa Diamant (protupožarna izolacija, poboljšana zvučna izolacija, vlagootpornost) d= 1,25 cm gustoće cca 1024 kg/m3. U međuprostor se postavlja 10 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN 13162. Gipskartonske ploče se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. Na tako postavljene gipskartonske ploče, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). ZVUČNA IZOLACIJA stijene W112 - Diamant pregradni zid debljine 15,0 cm JE 63 dB (A) – prema specifikacijama proizvođača. Preporuka je da se Knauf ploče spajaju klamanjem, a ne vijcima, jer se dobije još bolja zvučna izolacija izvedenih zidova. OTPORNOST NA POŽAR stijene W112 - Diamant pregradni zid debljine 15,0 cm JE EI 90 – prema specifikacijama proizvođača. U = 0,32 W/m2K

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 33

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

UZ5 Unutarnji laki pregradni zid (sanitarije i sl.), laka pregradna stijena od gipskartonskih ploča na metalnoj potkonstrukciji - debljine 10,0 cm; kao Knauf pregradni zid W112; jednostruka podkonstrukcija + dvoslojna obloga

- gipskartonske ploče (700-825 kg/m3) na metalnoj potkonstrukciji, 2 x 12,5 mm; obične (Knauf ploča A 13) ili vodootporne prema potrebama prostora u kojem se nalaze (Knauf ploča H2 13) ili vatrootporne prema mjerama zaštite od požara (Knauf ploča DF 13) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0)

2,5 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima - kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne obloge je 5 cm

5 cm

- gipskartonske ploče (700-825 kg/m3) na metalnoj potkonstrukciji, 2 x 12,5 mm; obične (Knauf ploča A 13) ili vodootporne prema potrebama prostora u kojem se nalaze (Knauf ploča H2 13) ili vatrootporne prema mjerama zaštite od požara (Knauf ploča DF 13) ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A2-s1, d0)

2,5 cm

Potkonstrukcija je od čeličnih CW ili MW profila širine 5 cm i obostrano se oblaže dvostrukom oblogom od gipskartonskih ploča d= 1,25 cm gustoće cca 700-825 kg/m3 (ovisno o vrsti obložne ploče). U međuprostor se postavlja 5 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN 13162. Gipskartonske ploče se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama. Ukoliko se pregrada nalazi na granici požarnih sektora postavljaju se protupožarne ploče. A ukoliko je to "mokri" prostor (sanitarije, kuhinja...) postavljaju se vodootporne ploče. Na tako postavljene gipskartonske ploče, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene keramičke pločice (prostori sanitarija i sl.). ZVUČNA IZOLACIJA stijene W112 pregradni zid s običnim gipskartonskim pločama debljine 10,0 cm JE 54 dB (A) – prema specifikacijama proizvođača. Preporuka je da se Knauf ploče spajaju klamanjem, a ne vijcima, jer se dobije bolja zvučna izolacija izvedenih zidova. OTPORNOST NA POŽAR stijene W112 pregradni zid s običnim gipskartonskim pločama debljine 10,0 cm JE min.EI 60 – prema specifikacijama proizvođača. U = 0,55 W/m2K Ostakljeni elementi pročelja i otvori: PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo Prozori, ostakljena ulazna vrata i staklene stijene su predviđene u plastificiranim aluminijskim okvirima, s prekinutim toplinskim mostom i toplinski poboljšanim svojstvima, ostakljenje IZO staklom; dva sloja stakla 4+16+6 mm (4 LowE + 16/argon + 6). Minimalni razmak između stakla je 12 mm, jedno staklo mora biti low energie staklo (vanjska strana unutarnjeg stakla), a međurazmak je ispunjen plinom argonom. Prema potrebi unutarnje staklo sigurnosno lamelirano – veće staklene površine i prema potrebi prostora. Prozori imaju mogućnost otvaranja zbog prirodne ventilacije prostora. Prozori i balkonska vrata su otklopno zaokretni ili klizni. Koeficijent prolaza topline za staklo Ug min. = 1,10 W/m2K, dok koeficijent prolaza topline za okvir Uokvira min. = 2,40 W/m2K. Navedene vrijednosti su najveće vrijednosti koeficijenta prolaza topline za staklo i za okvir, te prilikom izbora ostakljenih dijelova pročelja Investitor je dužan pridržavati ih se, a izbor boljeg stakla odnosno okvira će rezultirati i boljom toplinskom zaštitom. Ukupni koeficijent prolaza topline prozora treba iznositi maximalno Uw = 1,60 W/m2K (ovisno o udjelu profila u površini prozora), odnosno u prosjeku Uw = 1,49 W/m2K (udio ostakljenja u ploštini otvora odnosno udio ostakljenja u odnosu na okvir je 0,70). U = 1,49 W/m2K < 1,60 W/m2K

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 34

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Zaštita od sunčevog zračenja: Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60. Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i maksimalnim g = 0,60. Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od sunca je riješena s mutnim neprozirnim staklom s g = 0,60. Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite od sunca je riješena sa staklom koje ima g = 0,33. Određeno staklo (boju) odabrati prema podatku da je maksimalni g = 0,60 odnosno 0,45. g = 0,60 za otvore sa vanjskom zaštitom od sunca g = 0,60 za otvore sa unutarnjom zaštitom od sunca i strehom (prizemlje) g = 0,60 za manje otvore na sjevernoj i južnoj strani dvorane za ergonomiju g = 0,33 ulazna ostakljena vrata (sjeverno i južno pročelje) - provjeriti V1 Vanjska vrata grijanih prostora - neprozirno vratno krilo Vrata su predviđena u plastificiranim aluminijskim okvirima s prekinutim toplinskim mostom i toplinski poboljšanim svojstvima te s ispunom punog glatkog sendvič krila toplinskom izolacijom. Moguće je manje ostakljenje IZO staklo 4+12+4 mm, a ispuna (sendvič panel) prema izboru projektanta. Ukupni koeficijent prolaza topline vrata mora iznositi najviše Ud=2,00 W/m2K. U = 2,00 W/m2K ≤ 2,00 W/m2K V2 Vrata grijanog prostora prema negrijanom prostoru (spremište u prizemlju) Protupožarna vrata prema negrijanom prostoru spremišta, predviđena od metalnih okvira s prekidom toplinskog mosta i toplinski poboljšanim svojstvima. Ispunom punog glatkog sendvič krila toplinskom izolacijom. Ukupni koeficijent prolaza topline vrata mora iznositi Ud = 2,00 W/m2K. U = 2,00 W/m2K ≤ 2,00 W/m2K U Zagrebu, siječanj 2020. godine Projektant : Željka Veseljak, dipl.ing.arh.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 35

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

B) PROGRAM KONTROLE I OSIGURANJA KVALITETE U ODNOSU NA GRAĐEVNE PROIZVODE KOJI SE UGRAĐUJU U ZGRADU U SVRHU UŠTEDE TOPLINSKE ENERGIJE I TOPLINSKE ZAŠTITE 1. UVOD Program kontrole i osiguranja kvalitete izrađen je na temelju Zakona o gradnji (NN 153/2013, 020/2017, 039/2019, 125/2019), Zakona o građevnim proizvodima (NN br. 076/2013, 030/2014, 130/2017, 039/2019) i ostaloj regulativi i direktivama vezanim uz građevne proizvode. Građevni proizvodi smiju se staviti u promet (i koristiti za građenje) samo ako su uporabivi, tj. ako imaju takva svojstva da građevina u koju će se ugraditi ispuni temeljne zahtjeve: 1. mehanička otpornost i stabilnost 2. sigurnost u slučaju požara 3. higijena, zdravlje i okoliš 4. sigurnost i pristupačnost tijekom uporabe 5. zaštita od buke 6. gospodarenje energijom i očuvanje topline 7. održiva uporaba prirodnih izvora. Građevni proizvod je uporabiv, ako su njegova tehnička svojstva sukladna svojstvima određenim normom na koju upućuje tehnički propis, tehničko dopuštenje ili tehnički propis. Uporabivost građevnog proizvoda dokazuje se Izjavom svojstvima građevnog proizvoda koja se izdaje nakon provedbe odnosno osiguranja provedbe postupka ocjenjivanja sukladnosti tehničkih svojstava proizvoda s tehničkim svojstvima određenim za taj proizvod tehničkom specifikacijom ili tehničkim propisom. Izjava o svojstvima, odnosno njezina preslika dostavlja se tiskana na papiru ili drugom prikladnom materijalu ili elektroničkim putem primatelju građevnog proizvoda. Isto tako: - tehničke upute moraju sadržavati sigurnosne obavijesti, podatke značajne za čuvanje, transport, ugradnju i

uporabu građevnog proizvoda te moraju biti pisane na hrvatskom jeziku latiničnim pismom. - u tehničkim uputama mora biti naveden rok do kojega se građevni proizvod smije ugraditi, odnosno da taj rok

nije ograničen. - uz pisani tekst, tehničke upute mogu sadržavati nacrte i ilustracije. - tehničke upute moraju slijediti svaki građevni proizvod koji se isporučuje. Kada se dva ili više istih građevnih

proizvoda isporučuju odjednom, tehničke upute moraju slijediti svako pojedinačno pakiranje. - kod isporuke građevnog proizvoda u rasutom stanju tehničke upute moraju slijediti svaku pojedinačnu isporuku. Od strane izvoditelja radova obavezna je dostava Izjave o svojstvima (DOP) za sve ugrađene toplinsko-izolacijske materijale i toplinske sustave. Ukoliko dolazi do promjene toplinsko-izolacijskih materijala, zamijenjeni materijali moraju po svemu biti u skladu sa svojstvima danima u ključu za obilježavanje projektom predviđenih toplinsko-izolacijskih materijala. Kontrolni postupak ispitivanja obuhvaća i vizualni pregled dopremljenih građevinskih materijala i izvedenih radova koji bi u svemu trebali biti izvedeni prema pravilima struke, odnosno prema zahtijevanim hrvatskim normama. Tehnička svojstva građevnih proizvoda koji se ugrađuju u građevinu u svrhu uštede toplinske energije i toplinske zaštite moraju ispunjavati zahtjeve iz hrvatskih normi ili moraju imati tehnička dopuštenja donesena u skladu s relevantnim zakonom. Vrste građevnih proizvoda su: - toplinsko-izolacijski materijali - samonosivi sendvič-izolacijski paneli s obostranim metalnim slojem - zidovi i proizvodi za zidanje. Prije ugradnje u građevinu mora se ispitati (dokazati) vrijednost koeficijenta toplinske provodljivosti toplinsko- izolacijskih materijala, kako bi se dobivenim vrijednostima provjerilo zadovoljenje zahtjeva iz tablice 5 (Projektne vrijednosti toplinske provodljivosti, [W/(mK)] i približne vrijednosti faktora otpora difuziji vodene pare µ (-)) u

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 36

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Tehničkom propisu o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018). Propustljivost zraka i vode kod prozora i balkonskih vrata ne smije biti veća od vrijednosti utvrđenih normom HRN EN 1026:2001. Kod ugradnje toplinsko-izolacijskih materijala za prohodne krovove potrebno je provjeriti da izolacijski materijali zadovoljavaju minimalnu čvrstoću za prohodne krovove. NAPOMENA ZA UGRADNJU MATERIJALA ZA TOPLINSKU, ZVUČNU I PROTUPOŽARNU IZOLACIJU: Zidovi: - kao dodatna toplinska zaštita zidova izvodi se ETICS-sustav (povezani sustav za vanjsku toplinsku izolaciju) s

toplinskom izolacijom od ploča polistirena odnosno mineralne (kamene) vune koji po svemu mora zadovoljavati uvjete ETAGA-004. Sve radove na izvedbi sustava izvesti u skladu s uputama proizvođača (distributera) sustava i pravilima struke. Ploče se linijski po rubovima i točkasto po sredini (ca. 40% površine ploče), lijepi polimerno-cementnim ljepilom za lijepljenje proizvoda od polistirena odnosno mineralne vune, debljine ne veće od 0,5 cm. U slučaju postojanja neravnina zidova većih od normama dozvoljenih, izravnanja izvršiti slojem lagane ili produžne podložne žbuke. Ploče se trebaju dodatno pričvrstiti pričvrsnicama. Preko sloja izolacije nanosi se ljepilo u debljini od približno 3,00 mm u koje se utiskuje staklena, alkalno-otporna mrežica. Sistemom "mokro na suho" nanosi se sljedeći sloj ljepila debljine 2,00 mm. Nakon minimalno 7-10 dana sušenja nanosi se sloj za izjednačavanje vodoupojnosti (impregnacijski predpremaz) preko kojeg se nanosi završni sloj na osnovu silikata ili silikona. Ploče polistirena odnosno mineralne (kamene) vune lijepe se linijski po rubovima i točkasto po sredini, uz obaveznu primjenu mehaničkih spojnica po shemi "W" (vidi smjernice proizvođača!).

- primjena proizvoda od kamene vune preporuča se radi kvalitetnih svojstava toplinske i zvučne zaštite, protupožarnosti (negorivi proizvod!), kvalitetnije paropropusnosti (manja opasnost od razvoja plijesni i gljivica), dugovječnosti, zanemarivog toplinskog rada, veće otpornosti na udar (udar tuče), te mogućnosti lakšeg izlaska vlage iz AB-konstrukcije, čime se sprečava pojava preuranjene korozije armature i betona.

- sve fasaderske radove izvesti prema pravilima struke i povoljnim klimatskim uvjetima (optimalna temperatura i vlažnost vanjskog zraka, utjecaj sunčevih zračenja, kiša, magla,..).

- obavezna izvedba špaletnih elemenata uz rubove prozora, ako postoje, te dodatnih ojačanja po uglovima kako bi se izbjegla pucanja završnih slojeva uslijed djelovanja skretnih sila na uglovima.

- kao toplinska izolacija zidova u kontaktu s tlom, koristi se ekstrudirani polistiren koji se linijski i točkasto lijepi o podlogu, te još ispod razine tla dodatno mehanički zaštićuje čepićastim trakama. Iznad razine tla kao završni sloj koristiti vodoodbojne slojeve na osnovu polimera (prema uputama proizvođača). Armirano-betonske zidove prethodno izravnati slojem mase za izravnavanje ili tankim slojem cementne žbuke.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 37

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Podovi: - kod plivajućih podova voditi računa o tome da se ploče toplinske izolacije spajaju bez reški, kako bi se u najvećoj

mogućoj mjeri umanjili utjecaji zračnih šupljina. Ukoliko se kao toplinska i zvučna izolacija (međukatne konstrukcije) koriste ploče od kamene vune, obavezna primjena PE-folije s obje strane izolacije. U slučaju primjene ploča od elastificiranog polistirena, PE-folija je potrebna samo s gornje strane toplinsko-izolacijskog sloja. PVC folija se ne smije primjenjivati u kontaktu s polistirenima. Kod međukatnih konstrukcija između grijanih prostora folije idu s obje strane i uloga im je sprečavanje prodora zaostale vlage iz AB-stropova, odnosno vlage iz svježeg cementnog estriha. Preporuka je armiranje estriha armaturnim mrežama, iako se isti mogu i mikroarmirati polipropilenskim ili čeličnim vlaknima, ali uz kvalitetno umješavanje i po točno određenim "recepturama" proizvođača i/ili dobavljača vlakana. Ukoliko se kao izolacija koriste ploče polistirena, voditi računa da se prilikom ugradnje ugrađuju isključivo ploče samogasivog elastificiranog polistirena gustoće 15 kg/m³. Ukoliko su iste u kontaktu s PVC-folijama ili PVC hidroizolacijskim trakama moraju biti odijeljene uloškom neutralnog sloja PES-filc i sl.

Ravni krovovi (neprohodni i prohodni): - ugrađivati se smije samo suh i neoštećen proizvod. - proizvod se polaže na pripremljenu suhu podlogu. - prilikom polaganja proizvoda na otvorenom potrebno je spriječiti moguće oštećenje uslijed djelovanja

atmosferilija (kiša, snijeg). - prilikom ugradnje proizvoda, potrebno je pridržavati se redoslijeda ugradnje pojedinih slojeva konstrukcije danih

u projektnoj dokumentaciji, odnosno projektu u odnosu na toplinsku zaštitu i uštedu energije, te prospektnoj dokumentaciji i preporukama od strane proizvođača.

- tijekom dostave proizvoda (uvijek na paletama), isti se NIKAKO ne smiju položiti direktno na ploče toplinske izolacije (i hidroizolaciju), već ISKLJUČIVO na prethodno položenu podlogu (daske, ploče od iverice i sl.) preko sloja izolacije.

- ukoliko se vrši transport materijala i opreme direktno preko sloja toplinsko-izolacijskih ploča, obavezna je postava hodnih staza od dasaka ili ploča od iverica ili sl., preko spomenutog sloja.

Izvor: Program kontrole i osiguranja kvalitete od strane tvrtke Knauf Insulation d.o.o., Novi Marof 2. GRAĐEVNI PROIZVODI Građevni proizvodi koji se ugrađuju u predmetnu zgradu radi ispunjenja zahtjeva uštede toplinske energije i toplinske zaštite zgrade, ili pored ostalih funkcija značajnije doprinose ispunjenju tog zahtjeva, su: Elastificirani ekspandirani polistiren za prigušenje udarnog zvuka u plivajućim podovima (EPS T, EPS EL…) Elastificirani ekspandirani polistiren za prigušenje udarnog zvuka u podovima ima zadaću prigušenja udarnog zvuka i povećanja izolacije protiv zračnog zvuka te osiguranja propisane minimalne vrijednosti toplinske izolacije. Namjena zvučno izolacijskog ekspandiranog polistirena (stiropora) je da se spriječi kontakt hodne obloge poda sa nosivom konstrukcijom (tzv "plivajući pod"). Ukoliko je potrebna zvučna izolacija i dodatna toplinska izolacija, elastificirani ekspandirani polistiren (stiropor) se ugrađuje kao prvi sloj na nosivu stropnu konstrukciju. Najnovija tehnologija izrade elastificiranog ekspandiranog polistirena osigurava najbolju izolaciju protiv udarnog zvuka (topota) jer daje niske vrijednosti dinamičke krutosti pri maloj stišljivosti. Karakteristike elastificiranog ekspandiranog polistirena: zatvorena struktura ćelija – ne upija vodu, odličan toplinski izolator, postojan i trajan, jednostavan za ugradnju, mala promjena debljine ploče pod opterećenjem (stišljivost najviše do 3 mm), sprječava nastanka građevinskih oštećenja zbog kondenzacije vodene pare koja difuzijom ulazi u građevinski dio zgrade, dobra mehanička svojstva pri maloj težini, prihvatljiv za ljudsko zdravlje i okoliš, teško zapaljiv i ne podržava gorenje, otporan na organska otapala (npr. resitol, lakovi na bazi nitra, benzin i sl.). Ploče ekspandiranog polistirena koje će se ugrađivati moraju zadovoljiti zahtjeve iz točke 4.2 norme HRN EN 13163:2012+A2:2016 i slijedeće zahtjeve:

- nazivna debljina ploča u ugrađenom stanju d = 10 mm (11/10mm) odnosno d = 20 mm (22/20mm), - nazivna duljina ploča l = 1000 mm, - nazivna širina ploča b = 500 mm,

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 38

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

- projektna vrijednost toplinske provodljivosti elastificiranog ekspandiranog polistirena ≤ 0,042 W/(mK) ili bolja

- koeficijent difuzijskog otpora vodenoj pari μ: 20 - 40 - mala dinamička krutost (SD = 15 do 30 MN/m3), koja omogućuje visoku zvučnu izolaciju (ΔLw,R) od 19 do

30 dB ovisno o debljini sloja = smanjenje provođenja zvuka udara (d = 1cm / 2cm / 3cm) = 19 / 22 / 26 ΔLw [dB],

- reakcija na požar (prema HRN EN 13501-1): E, - ugrađeni proizvod mora imati svojstva navedena u donjoj kodiranoj oznaci ili povoljnija:

EPS - HRN EN 13163 - L3 - W3 - T1 - S5 - P10 - CP4 – SD30/SD15 Ekspandirani polistiren (stiropor), u funkciji toplinske izolacije poda (EPS) Ekspandirani polistiren u sastavu konstrukcija ima funkciju zadovoljenja propisane toplinske izolacije podova (poda na tlu, međukatnih konstrukcija, poda iznad negrijanog, poda iznad otvorenog prostora i sl.) s normalnim opterečenjem. U podove se ugrađuju višenamjenske izolacijske ploče od ekspandiranog polistirena, EPS 100 ili EPS 150. Ploče je moguće ugraditi sa i bez preklopa. Karakteristike elastificiranog ekspandiranog polistirena: odličan toplinski izolator, postojan i trajan, dimenzijski stabilan, jednostavan za ugradnju, sprječava nastanka građevinskih oštećenja zbog kondenzacije vodene pare koja difuzijom ulazi u građevinski dio zgrade, dobra mehanička svojstva pri maloj težini, teško zapaljiv i ne podržava gorenje, prihvatljiv za ljudsko zdravlje i okoliš, otporan na organska otapala (npr. resitol, lakovi na bazi nitra, benzin i sl.). Ploče ekspandiranog polistirena koje će se ugrađivati moraju zadovoljiti zahtjeve iz točke 4.2 norme HRN EN 13163:2012+A2:2016 i slijedeće zahtjeve:

- nazivna debljina ploča d = 20 mm – 300 mm, - nazivna duljina ploča l = 1000 mm / l = 2000 mm - nazivna širina ploča b = 500 mm / b = 1000 mm - tlačna čvrstoća pri 10% def.: 100 kPa / 150 kPa - progibna čvrstoća: 150 kPa / 200 kPa - projektna vrijednost toplinske provodljivosti ekspandiranog polistirena ≤ 0,040 W/(mK) ili bolja - koeficijent difuzijskog otpora vodenoj pari μ: 30 - 70 - reakcija na požar (prema HRN EN 13501-1): E, - ugrađeni proizvod mora imati svojstva navedena u donjoj kodiranoj oznaci (za EPS 100) ili povoljnija:

EPS - HRN EN 13163 – L2 – W2 - T1 – S2 – P5 - DS(N)5 – BS150 - CS(10)100 Ekstrudirani polistiren u funkciji toplinske izolacije u vlažnoj zoni (XPS) Ekstrudirani polistiren u konstrukciji ima prvenstveno funkciju zadovoljenja propisane toplinske izolacije u konstrukcijama koje su izložene vlazi (u obrnutim i zelenim ravnim krovovima, ispod temeljne ploče, zidovi u zemlji, podnožje fasade - sokl). Ploče ekstrudiranog polistirena za ETISC sustav u podnožju zidova (sokl) mora imati hrapavu površinu za prihvat polimercementnog ljepila. Ploče je moguće ugraditi sa i bez preklopa. Karakteristike elastificiranog ekspandiranog polistirena: podnosi vrlo visoka tlačna opterečenja, praktički ne upija vodu, otporan na vlagu, otporan na smrzavanje, odličan toplinski izolator, postojan i trajan, dimenzijski stabilan, jednostavan za ugradnju, dobra mehanička svojstva pri maloj težini, adekvatna paropropusnost, prihvatljiv za ljudsko zdravlje i okoliš (bez prisutnosti CFC, HCFC i HFC spojeva), teško zapaljiv i ne podržava gorenje, otporan na organska otapala (npr. resitol, lakovi na bazi nitra, benzin i sl.). Ploče ekstrudiranog polistirena koje će se ugrađivati moraju zadovoljiti zahtjeve iz točke 4.2 norme HRN EN 13164:2012+A1:2015 i slijedeće zahtjeve:

- nazivna debljina ploča d = 20 mm – 180 mm, - nazivna duljina ploča l = 1250 mm - nazivna širina ploča b = 600 mm - tlačna čvrstoća pri 10% def.: ≥ 200 kPa - vlačna čvrstoća okomito na površinu: > 400 kPa - projektna vrijednost toplinske provodljivosti ekstrudiranog polistirena = 0,033 – 0,036 W/(mK) ovisno o

debljini ploča - koeficijent difuzijskog otpora vodenoj pari μ: 50 - reakcija na požar (prema HRN EN 13501-1): E, - ugrađeni proizvod mora imati svojstva navedena u donjoj kodiranoj oznaci ili povoljnija:

XPS - EN 13164 - T3 - CS(10)300 - TR 400 - DS(70,90) - DLT(2)5 - WL(T)1,5 - MU50

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 39

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Mineralna vuna u međukatnim, krovnim i podnim konstrukcijama (tvrde ploče mineralne vune) Mineralna vuna u međukatnim, krovnim i podnim konstrukcijama ima prvenstveno zadaću toplinske izolacije, ali i zvučne izolacije između etaža (međukatna konstrukcija). Karakteristike mineralne vune: gusta, vlaknasta struktura materijala, odličan toplinski izolator, negoriv proizvod, vodoodbojan, otporan na starenje, otporan na visoke temperature, kemijski neutralan. Ploče mineralne vune koje će se ugrađivati moraju zadovoljiti zahtjeve iz točke 4.2 norme HRN EN 13162:2012+A1:2015 i slijedeće zahtjeve:

- nazivna debljina ploča d = 40 mm – 140 mm, - nazivna duljina ploča l = 2000 mm / 2400 mm - nazivna širina ploča b = 600 mm / 1200 mm - projektna vrijednost toplinske provodljivosti mineralne vune ≤ 0,040 W/(mK) ili bolja - tlačna čvrstoća pri 10% def.: ≥ 50 kPa - faktor otpora difuziji vodene pare μ: 1 - reakcija na požar (prema HRN EN 13501-1): A1, - ugrađeni proizvod mora imati svojstva navedena u donjoj kodiranoj oznaci ili povoljnija:

MW - HRN EN 13162 -T5 - DS(TH) - CS(10)30 – TR10 - PL(5)450 – WS - WL(P) - AF5 – MU1 Mineralna vuna u lakim zidovima, lakim predstijenkama i spuštenim stropovima (mekša kamena vuna ili staklena vuna) Mineralna vuna u kao ispuna u lakim zidovima, lakim predstijenkama i spuštenim stropovima ima prvenstveno zadaću osiguranja potrebne vrijednosti toplinske izolacije, ali i povećanja vrijednosti zvučne izolacije (od zračnog zvuka) uz optimalnu protupožarnu zaštitu. Karakteristike mineralne vune: gusta, vlaknasta struktura materijala, odličan toplinski izolator, veliki otpor uzdužnom strujanju zraka, negoriv proizvod, vodoodbojan, otporan na starenje, otporan na visoke temperature, kemijski neutralan. Ploče / role mineralne vune koje će se ugrađivati moraju zadovoljiti zahtjeve iz točke 4.2 norme HRN EN 13162:2012+A1:2015 i slijedeće zahtjeve:

- nazivna debljina ploča / rola d = 50 mm / 75 mm / 100 mm, - nazivna duljina ploča l = 1000 mm; rola 15000 mm / 11000 mm / 8000 mm - nazivna širina ploča b = 625 mm; rola b = 2 x 625 mm - projektna vrijednost toplinske provodljivosti mineralne vune ≤ 0,040 W/(mK) ili bolja - uzdužni otpor strujanju zraka: r > 5 kNs/m2 - faktor otpora difuziji vodene pare μ: 1 - reakcija na požar (prema HRN EN 13501-1): A1, - ugrađeni proizvod mora imati svojstva navedena u donjoj kodiranoj oznaci ili povoljnija:

MW - HRN EN 13162 - T5 – WS - AF5 - MU1 odnosno za staklenu vunu: MW - HRN EN 13162 - T2 – WS - WL(P) - AF5 - MU1

Kod postave toplinske izolacije u lakim konstrukcijama i prilikom postavljanja toplinske izolacije sa unutarnje strane obodnih zidova grijanog prostora, obavezna je postava parne brane s toplije strane toplinske izolacije. Fasadni sustav ETICS s mineralnom vunom (MW-PT) ETICS je povezani sustav za vanjsku toplinsku izolaciju, u ovom slučaju na bazi mineralne vune. Sastoji se od sloja ljepila, ploča mineralne vune, temeljnog armiranog sloja i završnog sloja, uključivo potrebne dodatne elemente: pričvrsnice, kutne profile i dr. MW ploče se na podlogu (zid) pričvršćuju se metodom nanošenja trakasto po rubu i točkasto po sredini pokrivajući minimalno 40% površine ploče ili metodom potpunog pokrivnog nanošenja na ploču. Ukoliko se ljepilo nanosi na podlogu treba koristiti isključivo metodu potpunog pokrivnog nanošenja. MW ploče – lamele (vlakna okomita na ravninu) se na podlogu (zid) pričvršćuju se isključivo metodom potpunog pokrivnog nanošenja na ploču ili podlogu. Ploče minerale vune se pričvršćuju dodatno mehanički s odgovarajućim pričvrsnicama s tiplima i tanjurastom perforiranom glavom promjera ≥ 60 mm, u količini 6 - 12 pričvrsnica po metru kvadratnom zida (ovisno o nosivosti pričvrsnice, lokaciji građevini, visini, mjestu pročvršćenja i sl.). Kod primjene toplinsko-izolacijskih lamela od mineralne vune (vlakna okomita na ravninu) potrebno je primijeniti pričvrsnice s glavom promjera ≥ 140 mm.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 40

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Izvedba sustava mora biti u skladu s uputama proizvođača sustava. Sve komponente ETICS sustava moraju biti međusobno usklađene, njihova svojstva utvrđena ispitivanjima, a sustav kao cjelina mora posjedovati certifikat sukladnosti s HRN EN 13499:2004 u skladu s HRN EN 13172:2012. Sva u nastavku navedena tehnička svojstva ETICS sustava i njegovih komponenata utvrđuju se normama na koje se upućuje u osnovnoj normi za proizvod HRN EN 13499:2004:

- projektna vrijednost toplinskog otpora ugrađenog ETICS sustava treba biti R ≥ 3,75 m2K/W, - vlačna čvrstoća prionjivosti između ljepila i podloge te ljepila i temeljnog armiranog sloja na ploču mineralne

vune ne smije biti manja od po 80 kPa, - MW ploče koje se upotrebljavanju u sustavu ETICS su:

- nazivna debljina ploča d = 50 mm – 220 mm - nazivna duljina ploča l = 1200 mm, - nazivna širina ploča b = 400 mm – 600 mm, - tlačna čvrstoća pri 10% def.: ≥ 10 kPa - delaminacijska čvrstoća: ≥ 5 kPa - projektna vrijednost toplinske provodljivosti mineralne vune ≤ 0,040 W/(mK) ili bolja - faktor otpora difuziji vodene pare μ: 1 - reakcija na požar (prema HRN EN 13501-1): A1, - ugrađeni proizvod mora imati svojstva navedena u donjoj kodiranoj oznaci ili povoljnija

MW - EN 13162 - T5 - CS(10)10 - TR5 – WS - WL(P) - MU1. - za armiranje temeljnog sloja treba upotrijebiti mrežicu od alkalno otpornih staklenih vlakanaca, vlačne čvrstoće

veće od 40 N/mm, a odnos vlačne čvrstoće prema istezanju kod loma ne smije biti manji od 1kN/mm, - temeljni armirani sloj sa završnim slojem ili bez njega ne smije propustiti vodu u količini većoj od 0,5 kg/(m2h0,5), - gustoća difuzijskog toka vodene pare za temeljni i završni sloj ne smije biti manja od 20 g/(m2d), - trajnost i prionjivost završnog sloja na temeljni armirani sloj treba zadovoljiti zahtjeve iz točke 4.11 norme HRN

EN 13499:2004, - čvrstoća na udar izvedenog ETICS sustava treba odgovarati razini I2, a na dijelu zida visine do 2 metra iznad

okolnog tla, razini I10 - otpornost protiv prodiranja izvedenog ETICS sustava treba odgovarati razini PE200

Temeljem gore izloženog za ugradnju je prikladan ETICS sustav oznake: ETICS – MW – HRN EN 13499 – 2.00 – B – I2 – PE200 Može se ugraditi i sustav ETICS povoljnijih svojstava od gore navedenih. U podnožju zida (sokl) do visine 30 cm od razine tla umjesto MW ploča ugraditi će se XPS (ekstrudirani polistiren) ploče jednake debljine, s hrapavom površinom radi bolje prionjivosti, koje imaju minimalne svojstva navedena u kodiranoj oznaci: XPS – HRN EN 13164 – T3 – CS(10\y)200 – DS(TH) – TR100 te zadovoljavaju i ostala svojstva iz točke 4.2 norme HRN EN 13164:2012. Klasa gorivosti cijelog klasificiranog ETICS sustava s MW po HRN EN 13501-1: A2-s1, d0. U pogledu zvučne izolacije konstrukcije ETICS sustav s MW daje +6 dB. Folija od ekstrudiranog polietilena - Dow Chemical Ethafoam 222-E / QUASH TM EF Meka zvučno izolacijska folija od ekstrudiranog polietilena u podovima ima zadaću prigušenja udarnog zvuka i povećanja izolacije protiv zračnog zvuka. U debljini od 5 mm omogućuje prigušenje buke od DL=19 dB, dok kod postavljanja u dva sloja (2x0,5 cm), postiže ΔLw = 25 dB. Lako se prilagođuje neravninama što omogućuje besprijekornu obradu i zaštitu svih detalja – obodni pojas podne ploče, prodore oko cijevi itd. Foliju obavezno dignuti rubno uza zid (na spoju poda sa zidom); područje dodira podnog sustava potrebno je trakom folije do visine gotovog poda odvojiti/dilatirati od bočnih zidova; postavlja se prije početka ugradnje cementne glazure. Folije od ekstrudiranog polietilena koje će se ugrađivati moraju zadovoljiti zahtjeve iz točke 4.2 norme HRN EN 16069:2012+A1:2015 i slijedeće zahtjeve:

- nazivna debljina folije u ugrađenom stanju d = 4,3 mm (5/4,3mm), - nazivna duljina role l = 75 m, - nazivna širina role b = 1,5 m, - projektna vrijednost toplinske provodljivosti Dow Chemical Ethafoam 222-E ≤ 0,030 W/(mK) ili bolja - koeficijent difuzijskog otpora vodenoj pari μ: 3900 - mala dinamička krutost (SD ≤ 80 MN/m3), - reakcija na požar (prema HRN EN 13501-1): E.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 41

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Mineralna vuna u vanjskim konstrukcijama s ventiliranom oblogom Mineralna vuna u vanjskim konstrukcijama s ventiliranom oblogom ima prvenstveno zadaću toplinske izolacije zida uz optimalnu protupožarnu zaštitu. Karakteristike mineralne vune: gusta, vlaknasta struktura materijala, odličan toplinski izolator, negoriv proizvod, vodoodbojan, otporan na starenje, otporan na visoke temperature, kemijski neutralan. Ploče mineralne vune za ventilirana pročelja mogu biti kaširane crnim (ili bijelim) staklenim voalom čija je svrha zaštita od mehaničkog oštećenja, zaštita od oborinske vode, zaštita od rashlađenja izolacije, zaštita od osipanja uslijed strujanja zraka te očuvanje kompaktnosti ploče. Tako se kaširanjem ploča mineralne vune povećava djelotvornosti toplinske izolacije (vjetrovna brana), dodatno povećava vodoodbojnosti te zaštita od raslojavanja i osipanja izolacije uslijed jačeg strujanja zraka. Ploče pričvršćujemo mehaničkim plastičnim DH, odnosno čeličnim DMT nosačima izolacije. Ploče mineralne vune koje će se ugrađivati moraju zadovoljiti zahtjeve iz točke 4.2 norme HRN EN 13162:2012+A1:2015 i slijedeće zahtjeve:

- nazivna debljina ploča d = 40 mm – 200 mm, - nazivna duljina ploča l = 1000 mm - nazivna širina ploča b = 600 mm - projektna vrijednost toplinske provodljivosti mineralne vune ≤ 0,040 W/(mK) ili bolja - uzdužni otpor strujanju zraka: r > 5 kNs/m2 - faktor otpora difuziji vodene pare μ: 1 - čvrstoća na raslojavanje po HRN EN 1607: min. 1 kPa - reakcija na požar (prema HRN EN 13501-1): A1, - ugrađeni proizvod mora imati svojstva navedena u donjoj kodiranoj oznaci ili povoljnija:

MW - HRN EN 13162 - T5 - DS(TH) - CS(10)0,5 - TR1 - WL(P) – Afr10 – MU1 Ostakljeni fasadni elementi Koeficijent prolaska topline ostakljenih fasadnih elemenata treba biti manji od U = 1,60 W/(m2K). Dokazuje se proračunom ili mjerenjem metodom vruće komore prema HRN EN ISO 12567-1:2011. Zrakonepropusnost reški prozora i vanjskih vrata mjeri se prije njihove ugradnje i mora zadovoljiti razred zrakopropusnosti 2 prema HRN EN 12207-1:2017. Polistiren koji se upotrebljava za toplinsku izolaciju s vanjske strane hidroizolacije u vlažnoj zoni, je ekstrudirani polistiren XPS gustoće 40 kg/m³, ploče s rubnim preklopom; Polistiren u slojevima poda u ulozi zvučne izolacije je elastificirani samogasivi ekspandirani polistiren prostorne mase 15 kg/m3, prethodno u skladištu odležan 3 mjeseca. Polistiren mora biti prethodno odležan u skladištu 3 mjeseca prije ugradnje kako bi bile dimenzionalno stabilne. Polietilenske folije se ne smiju zamijeniti PVC folijama, a ploče ekspandiranog ili ekstrudiranog polistirena u kontaktu s PVC folijama ili PVC hidroizolacijskim trakama moraju biti odijeljene uloškom neutralnog sloja – PES filc ili sl. Svi ugrađeni materijali trebaju imati ateste od u Hrvatskoj mjerodavnih institucija. U nastavku se navodi popis svih normi koji se moraju primjenjivati, a odnose se na materijale i ispitivanja u odnosu na racionalnu upotrebu energije i toplinsku zaštitu.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 42

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

3. POPIS HRVATSKIH NORMI I DRUGIH TEHNIČKIH SPECIFIKACIJA KOJE UPUĆUJU NA ZAHTJEVE KOJE, U SVEZI S TOPLINSKOM ZAŠTITOM, TREBAJU ISPUNITI TOPLINSKO-IZOLACIJSKI GRAĐEVNI PROIZVODI ZA ZGRADE

HRN EN 13162:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od mineralne vune (MW) -- Specifikacija (EN 13162:2012) Thermal insulation products for buildings -- Factory made mineral wool (MW) products -- Specification (EN 13162:2012) HRN EN 13163:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekspandiranog polistirena (EPS) -- Specifikacija (EN 13163:2012) - Thermal insulation products for buildings -- Factory made expanded polystyrene (EPS) products -- Specification (EN 13163:2012) HRN EN 13164:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekstrudirane polistirenske pjene (XPS) -- Specifikacija (EN 13164:2012)- Thermal insulation products for buildings -- Factory made extruded polystyrene foam (XPS) products -- Specification (EN 13164:2012) HRN EN 13165:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od tvrde poliuretanske pjene (PUR) -- Specifikacija (EN 13165:2012)- Thermal insulation products for buildings -- Factory made rigid polyurethane foam (PU) products -- Specification (EN 13165:2012) HRN EN 13166:2012 - Toplinsko izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od fenolne pjene (PF) -- Specifikacija (EN 13166:2012)- Thermal insulation products for buildings -- Factory made phenolic foam (PF) products -- Specification (EN 13166:2012) HRN EN 13167:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ćelijastog (pjenastog) stakla (CG) -- Specifikacija (EN 13167:2012) - Thermal insulation products for buildings -- Factory made cellular glass (CG) products -- Specification (EN 13167:2012) HRN EN 13168:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od drvene vune (WW) -- Specifikacija (EN 13168:2012) -Thermal insulation products for buildings -- Factory made wood wool (WW) products -- Specification (EN 13168:2012) HRN EN 13169:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekspandiranog perlita (EPB) -- Specifikacija (EN 13169:2012) -Thermal insulation products for buildings -- Factory made expanded perlite board (EPB) products -- Specification (EN 13169:2012) HRN EN 13170:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekspandiranog pluta (ICB) -- Specifikacija (EN 13170:2012) Thermal insulation products for buildings -- Factory made products of expanded cork (ICB) -- Specification (EN 13170:2012) HRN EN 13171:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od drvenih vlakana (WF) -- Specifikacija (EN 13171:2012) -Thermal insulation products for buildings -- Factory made wood fibre (WF) products -- Specification (EN 13171:2012) HRN EN 13172:2012 - Toplinsko-izolacijski proizvodi -- Vrednovanje sukladnosti (EN 13172:2012) - Thermal insulation products -- Evaluation of conformity (EN 13172:2012) HRN EN 14314:2013 - Toplinsko-izolacijski proizvodi za instalacije u zgradama i industriji -- Tvornički izrađeni proizvodi od fenolne pjene (PF) -- Specifikacija (EN 14314:2009+A1:2013) HRN EN 14315-1:2013 - Toplinsko-izolacijski proizvodi za zgrade -- Proizvodi od prskane krute poliuretanske (PUR) i poliizocijanuratne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacija za sustav prskane krute pjene prije ugradnje (EN 14315-1:2013) HRN EN 14318-1:2013 - Toplinsko-izolacijski proizvodi za zgrade -- Proizvodi od injektirane krute poliuretanske (PUR) i poliizocijanuratne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacija za sustav injektiranja krute pjene prije ugradnje (EN 14318-1:2013)

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 43

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

HRN EN 14319-1:2013 - Toplinsko-izolacijski proizvodi za instalacije u zgradama i industriji -- Proizvodi od krute poliuretanske (PUR) i poliizocijanuratne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacije za sustav injektiranja krute pjene prije ugradnje (EN 14319-1:2013) HRN EN 14320-1:2013 - Toplinsko-izolacijski proizvodi za instalacije u zgradama i industriji -- Proizvodi od prskane krute poliuretanske (PUR) i poliizocijanuratne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacija za sustav prskane krute pjene prije ugradnje (EN 14320-1:2013) HRN EN 15732:2012 - Proizvodi ispunjeni laganim punjenjem i toplinsko-izolacijski proizvodi za primjenu u građevinarstvu (CEA) – Proizvodi od lakoagregatne kspandirane gline (LWA) (EN 15732:2012) HRN EN 16069:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od polietilenske pjene (PEF) -- Specifikacija (EN 16069:2012). HRN EN 13172:2012 - Toplinsko-izolacijski proizvodi -- Vrednovanje sukladnosti (EN 13172:2012)Thermal insulation products -- Evaluation of conformity (EN 13172:2012) HRN EN 1745:2012 - Zidovi i proizvodi za zidanje -- Metode određivanja toplinskih svojstava (EN 1745:2012) -Masonry and masonry products -- Methods for determining thermal properties (EN 1745:2012). 4. NORME ZA ISPITIVANJE NA KOJE UPUĆUJE PROPIS HRN EN 674:2012 Staklo u graditeljstvu -- Određivanje koeficijenta prolaska topline (U-vrijednost) -- Metoda sa zaštićenom vrućom pločom (EN 674:2011) HRN EN 1026:2016 Prozori i vrata -- Propusnost zraka -- Metoda ispitivanja (EN 1026:2000) HRN EN 12207:2017 Prozori i vrata -- Propusnost zraka -- Razredba (EN 12207:1999) HRN EN ISO 12412-2:2004 Toplinske značajke prozora, vrata i zaslona -- Određivanje koeficijenta prolaska topline metodom vruće komore -- 2. dio: Okviri (EN 12412-2:2003) HRN EN ISO 12567-1:2011 Toplinske značajke prozora i vrata -- Određivanje prolaza topline metodom vruće komore -- 1. dio: Prozori i vrata u cjelini (ISO 12567-1:2010+Cor 1:2010; EN ISO 12567-1:2010+AC:2010) HRN EN 9972:2015 Toplinske značajke zgrada -- Određivanje propusnosti zraka kod zgrada -- Metoda razlike tlakova (ISO 9972:2015; EN ISO 9972:2015) 5. TEHNIČKA SVOJSTVA I DRUGI ZAHTJEVI ZA GRAĐEVNE PROIZVODE "(1) Građevni proizvodi koji se ugrađuju u zgradu u svrhu racionalne uporabe energije i toplinske zaštite (u daljnjem tekstu: građevni proizvodi) moraju imati svojstva bitnih značajki propisanih posebnim propisom kojim su uređeni građevni proizvodi. (2) Građevni proizvod može se ugraditi ako: – je namijenjen za ugradnju u zgradu u svrhu racionalne uporabe energije i toplinske zaštite, – je za njega izdana izjava o svojstvima bitnih značajki građevnih proizvoda (dalje u tekstu: izjava o svojstvima) u skladu s posebnim propisom – je propisno označen,

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 44

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

– ispunjava druge zahtjeve propisane posebnim propisima kojima se uređuje stavljanje na tržište odnosno stavljanje na raspolaganje na tržište građevnih proizvoda. (3) Vrste građevnih proizvoda jesu: – toplinsko-izolacijski građevni proizvodi, – povezani sustavi za vanjsku toplinsku izolaciju (ETICS), – ziđe i proizvodi za zidanje (4) Građevni i drugi proizvodi koji se ugrađuju u zgradu u svrhu racionalne uporabe energije i toplinske zaštite proizvode se u tvornicama izvan gradilišta, te moraju biti međusobno usklađeni na način da nakon izvedbe osiguravaju ispunjavanje zahtjeva određenih važećim propisima. (5) Ocjenjivanje sukladnosti toplinsko-izolacijskih građevnih proizvoda za zgrade provodi se na način uređen u skladu s posebnim zakonom kojim se uređuje područje građevnih proizvoda." Izvor: Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) Zahtjevi za građevni proizvod ovisno o uvjetima, postupcima i drugim okolnostima građenja moraju se detaljnije razraditi u izvedbenom projektu 6. DOPUŠTENA ZRAKOPROPUSNOST OVOJNICE ZGRADE, VENTILIRANJE PROSTORA

ZGRADE "(1) Zgrada mora biti projektirana i izgrađena na način da građevni dijelovi koji čine ovojnicu grijanog prostora zgrade, uključivo spojnice između pojedinih građevnih dijelova i otvora ili prozirnih elemenata koji nemaju mogućnost otvaranja, budu minimalne zrakopropusnosti u skladu s dosegnutim stupnjem razvoja tehnike i tehnologije u vrijeme izrade projekta. (2) Zrakopropusnost prozora, balkonskih vrata i krovnih prozora mora ispuniti zahtjeve iz tablice 4. iz Priloga »B« Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018). (3) Iznimno od stavka 2. članka 26. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) dopuštena je i veća zrakopropusnost od propisane ako je to potrebno: – da se ne ugrozi higijena i zdravstveni uvjeti, i/ili – zbog uporabe uređaja za grijanje i/ili kuhanje s otvorenim plamenom. (4) Spojnice između punih građevnih dijelova ovojnice zgrade i otvora ili drugih prozirnih elemenata (prozori, vrata, ostakljene stijene, nadsvjetla i slično) moraju biti izvedene na razini minimalne tehnički ostvarive zrakopropusnosti, uz istovremeno sprječavanje pojave građevinskih šteta zbog unutrašnje kondenzacije (uslijed neadekvatne primjene brtvenih materijala ili folija niske paropropusnosti) i sprječavanje površinske kondenzacije na unutrašnjim stranama spojnica (uslijed nedovoljne razine, pozicije ili nepostojanja toplinske izolacije na spojnicama). (1) Broj izmjena unutarnjeg zraka s vanjskim zrakom kod zgrade u kojoj borave ili rade ljudi treba iznositi najmanje n= 0,5 h-1 ako propisom donesenim u skladu sa zakonom kojim se uređuje gradnja to područje nije drukčije propisano. (2) U vrijeme kada ljudi ne borave u dijelu zgrade koji je namijenjen za rad i/ili boravak ljudi, potrebno je osigurati izmjenu unutarnjeg zraka od najmanje n= 0,2 h-1. (3) Za izračun QH,nd prilikom projektiranja novih zgrada i rekonstrukcije postojećih zgrada, potrebno je broj izmjena zraka izračunati prema Algoritmu. (4) Najmanji broj izmjena zraka iz stavka 1. i stavka 2. članka 27. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) mora biti veći u pojedinim dijelovima zgrade ako je to potrebno: – da se ne ugrozi higijena i zdravstveni uvjeti, i/ili – zbog uporabe uređaja za grijanje i/ili kuhanje s otvorenim plamenom.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 45

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

(1) Ako nije moguće izvesti prirodnu ventilaciju za ispunjavanje kvalitete zraka u prostoru u skladu s propisima koji uređuju ventilaciju i klimatizaciju zgrada, može se projektirati i izvesti sistem hibridne ili mehaničke ventilacije. (2) Energetska učinkovitost ventilacijskog sustava ispunjava se izborom energetski učinkovitih uređaja i pripadajućih elemenata, energetski učinkovitim razvodom, najmanjom potrebnom količinom zraka, uravnoteženom regulacijom kvalitete zraka u zgradi, pojedinim dijelovima ili prostorima. (3) Ugrađeni mehanički ili hibridni sustavi ventilacije zgrada moraju ispuniti povrat topline iz istrošenog zraka sa sljedećim minimalnim stupnjevima korisnosti η: – kružni cirkulacijski sustav povrata topline: ukupni η≥0,55 (primjena samo u slučaju razdvojene montaže tlačne i odsisne ventilacijske jedinice), – ostali sustavi povrata topline: ukupni η≥0,70. (1) Ako se za ventiliranje zgrade osim prozora ili umjesto njih koriste i posebni uređaji s otvorima za ventiliranje, tada mora postojati mogućnost njihova jednostavnog ugađanja sukladno potrebama korisnika zgrade. (2) Odredba iz stavka 1. članka 29. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) ne primjenjuje se kod ugradnje uređaja za ventiliranje s automatskom regulacijom propusnosti vanjskog zraka. (3) Uređaji za ventiliranje u zatvorenom stanju moraju ispuniti zahtjeve utvrđene u tablici 4. iz Priloga »B« Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015). (1) Ispunjavanje zahtjeva o zrakopropusnosti iz odredbi članka 27. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) dokazuje se ispitivanjem na izgrađenoj novoj ili rekonstruiranoj postojećoj zgradi prema HRN EN 9972:2015, metoda određivanja A, prije tehničkog pregleda zgrade (blower door test). (2) Prilikom ispitivanja iz stavka 1. članka 30. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018), za razliku tlakova između unutarnjeg i vanjskog zraka od 50 Pa, izmjereni protok zraka, sveden na obujam unutarnjeg zraka, ne smije biti veći od vrijednosti n50= 3,0 h-1 kod zgrada ili pojedinih toplinskih zona zgrada bez mehaničkog uređaja za ventilaciju, odnosno n50 = 1,5h-1 kod zgrada ili pojedinih toplinskih zona zgrada s mehaničkim uređajem za ventilaciju. (3) Obvezna primjena zahtjeva iz stavka 1. članka 30. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) odnosi se na zgrade gotovo nulte energije i zgrade koje se projektiraju na: – Q’’H,nd≤25 kWh/(m2·a) kada srednja mjesečna temperatura vanjskog zraka najhladnijeg mjeseca na lokaciji zgrade jest > 3 °C prema podacima iz Meteoroloških podataka, odnosno – Q’’H,nd≤50 kWh/(m2·a) kada srednja mjesečna temperatura vanjskog zraka najhladnijeg mjeseca na lokaciji zgrade jest ≤3 °C prema podacima iz Meteoroloških podataka. (1) Za stambene zgrade koje imaju više od jednog stana zahtjevi iz članka 26., 27., 28., 29 i 30. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) moraju biti ispunjeni za svaki stan. (2) Za nestambene zgrade zahtjevi iz članaka 26., 27., 28., 29 i 30. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) odnose se na ovojnicu grijanog dijela zgrade." Izvor: Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) 7. PROZORI I VRATA (prema Tehničkom propisu za prozore i vrata (NN 069/2006)) Tehnička svojstva prozora i vrata moraju biti takva da, u predviđenom roku trajanja građevine, uz propisanu odnosno projektom određenu ugradnju i održavanje, oni podnesu sve utjecaje uobičajene uporabe i utjecaje okoline, tako da građevina u koju su ugrađeni ispunjava bitne zahtjeve. Prozori i vrata smiju se ugraditi u građevinu ako ispunjavaju zahtjeve propisane Tehničkim propisom za prozore i vrata (NN 069/2006) i ako su za prozor odnosno vrata izdane izjave o sukladnosti u skladu s odredbama posebnog propisa.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 46

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Dokumentacija s kojom se isporučuju prozori i/ili vrata mora sadržavati: – podatke koji povezuju radnje i dokumentaciju o sukladnosti prozora odnosno vrata i izjave o sukladnosti,

odnosno potvrde o sukladnosti prema Tehničkom propisu za prozore i vrata (NN 069/2006) – podatke u vezi s označavanjem prozora odnosno vrata propisane u Prilogu iz članka 7. stavka 1. Tehničkog

propisa za prozore i vrata (NN 069/2006) – druge podatke značajne za rukovanje, prijevoz, pretovar, skladištenje, ugradnju, uporabu i održavanje prozora

i/ili vrata te za njihov utjecaj na bitna svojstva i trajnost građevine. U slučaju nesukladnosti prozora odnosno vrata s tehničkim specifikacijama ili projektom za taj građevni proizvod, proizvođač prozora i/ili vrata mora odmah prekinuti njihovu proizvodnju i poduzeti mjere radi utvrđivanja i otklanjanja grešaka koje su nesukladnost uzrokovale. Ako dođe do isporuke nesukladnog prozora i/ili vrata proizvođač odnosno uvoznik mora, bez odgode, o nesukladnosti toga građevnog proizvoda obavijestiti sve kupce, distributere, ovlaštenu pravnu osobu koja je sudjelovala u potvrđivanju sukladnosti i Ministarstvo zaštite okoliša, prostornog uređenja i graditeljstva. Proizvođač odnosno uvoznik i distributer prozora i/ili vrata, te izvođač građevine, dužni su poduzeti odgovarajuće mjere u cilju održavanja svojstava prozora odnosno vrata tijekom rukovanja, prijevoza, pretovara, skladištenja i njihove ugradnje u građevinu. Izvor: Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) i Tehnički propis za prozore i vrata (NN 069/2006) 8. UVJETI ZA ODRŽAVANJE GRAĐEVINE U ODNOSU NA RACIONALNU UPORABU

ENERGIJE I TOPLINSKU ZAŠTITU Uvjeti za održavanje građevine su bazirani na kvalitetno izvedenim radovima i ugrađenim materijalima, redovitom investicijskom održavanju, popravcima odmah nakon uočenih neispravnosti i normalnom namjenskom korištenju građevine. Građevina se smije rabiti na način sukladan njezinoj namjeni. Vlasnik građevine dužan je osigurati održavanje građevine tako da se tijekom njezina trajanja očuvaju bitni zahtjevi za građevinu te ju održavati tako da se ne naruše svojstva građevine. U slučaju oštećenja građevine zbog kojeg postoji opasnost za život i zdravlje ljudi, okoliš, druge građevine i stvari ili stabilnost tla na okolnom zemljištu, vlasnik građevine dužan je poduzeti hitne mjere za otklanjanje opasnosti i na prikladan način označiti građevinu opasnom do otklanjanja oštećenja. Praćenje stanja građevine, povremene godišnje preglede građevine, izradu pregleda za održavanje i unapređivanje ispunjavanja bitnih zahtjeva za građevinu, utvrđivanje potrebe za obavljanje popravaka građevine i druge stručne poslove vlasnik građevine treba povjeriti stručnim osobama koje zadovoljavaju uvjete za obavljanje djelatnosti propisane važećim zakonima. Održavanje zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu mora biti takvo da se tijekom trajanja zgrade očuvaju njezina tehnička svojstva i ispunjavaju zahtjevi određeni projektom zgrade i Tehničkim propisom o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018), te drugi zahtjevi koje zgrada mora ispunjavati u skladu s posebnim propisom donesenim u skladu sa važećim Zakonima i Pravilnikom o održavanju građevina (NN 122/2014, 098/2019). Održavanje zgrade koja je izvedena odnosno koja se izvodi u skladu s prije važećim propisima u odnosu na racionalnu uporabu energije i toplinsku zaštitu mora biti takvo da se tijekom trajanja zgrade očuvaju njezina tehnička svojstva i ispunjavaju zahtjevi određeni projektom zgrade i propisima u skladu s kojima je zgrada izvedena. Održavanje zgrade u smislu racionalne uporabe energije i toplinske zaštite podrazumijeva:

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 47

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

– pregled zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu u razmacima i na način određen projektom zgrade i/ili na način određen posebnim propisom donesenim u skladu sa Zakonom o prostornom uređenju i gradnji, – izvođenje radova kojima se zgrada zadržava u stanju određenom projektom zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu i Tehničkim propisom o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) odnosno propisom u skladu s kojim je zgrada izvedena. Ispunjavanje propisanih uvjeta održavanja zgrade dokumentira se u skladu s projektom zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu, te: – izvješćima o pregledima i ispitivanjima zgrade i pojedinih njezinih dijelova, – zapisima o radovima održavanja, – na drugi prikladan način ako Tehničkim propisom o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) ili posebnim propisom donesenim u skladu sa važećim Zakonima i Pravilnikom o održavanju građevina (NN 122/2014, 098/2019) nije što drugo određeno. Za održavanje zgrade dopušteno je rabiti samo one građevne proizvode za koje je izdana isprava o sukladnosti prema posebnom propisu ili je uporabljivost dokazana u skladu s projektom zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu i Tehničkim propisom o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018). Prema Tehničkom propisu o racionalnoj upotrebi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018) održavanje zgrade u odnosu na racionalnu upotrebu energije i toplinsku zaštitu mora biti takvo da se tijekom trajanja zgrade očuvaju njezina tehnička svojstva i ispunjavaju zahtjevi određeni projektom zgrade i Tehničkim propisom, te drugi zahtjevi koje zgrada mora ispunjavati u skladu s posebnim propisom donesenim u skladu sa Zakonom o gradnji. Održavanjem zgrade, odnosno, ni na koji drugi način, ne smiju se ugroziti tehnička svojstva i ispunjavanje zahtjeva za zgradu propisanih Tehničkim propisom o uštedi energije i toplinskoj zaštititi u zgradama. Održavanje zgrade u smislu uštede toplinske energije i toplinske zaštite podrazumijeva: pregled zgrade u odnosu na uštedu energije i toplinsku zaštitu u razmacima i na način određen projektom zgrade i/ili na način određen posebnim propisom donesenim u skladu sa Zakonom o gradnji MINIMALNO DVA PUTA GODIŠNJE, u proljeće i kasnu jesen, kako bi se odmah i krovni oluci očistili od lišća, te na taj način spriječilo procurijevanje, odnosno začepljivanje oluka. Pri tome osobitu pozornost obratiti na sljedeće građevne dijelove: - krovovi - obavezna provjera osnovnog i ukoliko je moguće sekundarnog pokrova. Tu provjeru izvršiti obavezno

prije zime, ali i tijekom čitave godine kako bi se spriječio prodor oborinskih voda u konstrukciju krovišta i toplinsku izolaciju.

- zidovi - obavezna provjera završnih slojeva i saniranje eventualno nastalih pukotina kako bi se spriječio prodor vlage kroz njih, smrzavanje i razaranje strukture te konačan prodor vode unutar toplinske izolacije i konstrukcije zida.

Obavezna je također provjera stanja parnih brana i saniranje eventualno nastalih oštećenja. Važna napomena: Ukoliko se namjerava iz bilo kojeg razloga mijenjati projektirani toplinsko-izolacijski materijal, ugrađeni materijal NE SMIJE BITI LOŠIJE KVALITETE OD PROJEKTOM PREDVIĐENOG niti po jednom od bitnih parametara (koeficijent toplinske provodljivosti, paropropusnost, razred reakcije na požar, ...). Za sve ugrađene toplinsko-izolacijske materijale moraju se priložiti valjane potvrde, a za one koji ne odgovaraju projektom predviđenima sve potrebne suglasnosti i dokazi da isti ne narušavaju proračunom dokazane vrijednosti. U Zagrebu, siječanj 2020. godine Projektant : Željka Veseljak, dipl.ing.arh.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 48

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

C) PRORAČUN FIZIKALNIH SVOJSTAVA ZGRADE GLEDE RACIONALNE UPORABE ENERGIJE I TOPLINSKE ZAŠTITE

PRILOG: Proračun fizikalnih svojstava zgrade glede racionalne uporabe energije i toplinske zaštite izrađen je u skladu s Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018), pomoću računalnog programa EnCert-HR2 verzija 2.42., za stvarne klimatske podatke, odnosno meteorološku postaju Zagreb - Grič. U proračunu zgrade su prema podatcima od glavnog projektanta i projektanta strojarskog dijela ovog glavnog projekta dani podatci zavisni o načinu grijanja, hlađenja, ventilacije i pripreme potrošne tople vode dok su prema podatcima od projektanta elektrotehničkog dijela ovog glavnog projekta dani podatci zavisni o rasvjeti, odnosno o obnovljivim izvorima energije i njihovom udjelu u ukupnoj potrebnoj energiji korištenoj u predmetnoj zgradi.

grijanje / hlađenje = 20°C / 22°C

Proračun je napravljen s računalnim programom EnCert-HR2; str. 1 - str. 51

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 1

Projekt racionalne uporabe energije i toplinske zaštite zgrade

napravljen za zgradu: DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

PRI ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA

prema zahtjevima iz Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama

"Narodne novine", broj. 128/15, 70/18, 73/18 i 86/18

Zgrada JE napravljena u skladu s Tehničkim propisom

Projektant: Željka Veseljak, dipl.ing.arh.

30.01.2020.

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 2

PROPISI I HRVATSKE NORME

Propisi Zakon o gradnji, NN 153/13, 20/17 Zakon o energetskoj učinkovitosti, NN 127/14 Pravilnik o energetskom pregledu zgrade i energetskom certificiranju NN (88/17) Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti zgrada NN 128/15, 70/18, 73/18 i 86/18 Tehnički propis za prozore i vrata NN 69/06 Tehnički propis za staklene konstrukcije NN 88/17 Hrvatske norme HRN EN 410:2011 Staklo u graditeljstvu -- Određivanje svjetlosnih i sunčanih značajka ostakljenja (EN 410:2011) HRN EN 673:2011 Staklo u graditeljstvu -- Određivanje koeficijenta prolaska topline (U vrijednost) -- Proračunska me-toda (EN 673:2011) HRN EN ISO 6946:2008 Građevni dijelovi i građevni dijelovi zgrade -- Toplinski otpor i koeficijent prolaska topline -- Me-toda proračuna (ISO 6946:2007; EN ISO 6946:2007) HRN ISO 9836:2011 Standardi za svojstva zgrada -- Definiranje i proračun površina i prostora (ISO 9836:2011) HRN EN ISO 10077-1:2008 Toplinska svojstva prozora, vrata i zaslona -- Proračun koeficijenta prolaska topline -- 1. dio: Općenito (ISO 10077-1:2006; EN ISO 10077-1:2006) HRN EN ISO 10077-1:2008/Ispr.1:2010 Toplinska svojstva prozora, vrata i zaslona -- Proračun koeficijenta prolaska topline -- 1. dio: Općenito (ISO 10077-1:2006/Cor 1:2009; EN ISO 10077-1:2006/AC:2009) HRN EN ISO 10211:2008 Toplinski mostovi u zgradarstvu -- Toplinski tokovi i površinske temperature -- Detaljni prora-čuni (ISO 10211:2007; EN ISO 10211:2007) HRN EN ISO 10456:2008 Građevni materijali i proizvodi -- Svojstva s obzirom na toplinu i vlagu -- Tablične projektne vrijednosti i postupci određivanja nazivnih i projektnih toplinskih vrijednosti (ISO 10456:2007; EN ISO 10456:2007) HRN EN 12464-1:2012 Svjetlo i rasvjeta – Rasvjeta radnih mjesta -- 1. dio: Unutrašnji radni prostori (EN 12464-1:2011) HRN EN 12524:2002 Građevni materijali i proizvodi -- Svojstva s obzirom na toplinu i vlagu -- Tablice projektnih vrijed-nosti (EN 12524:2000) HRN EN 12831:2004 Sustavi grijanja u građevinama -- Postupak proračuna normiranoga toplinskog opterećenja (EN 12831:2003) HRN EN ISO 13370:2008 Toplinske značajke zgrada -- Prijenos topline preko tla -- Metode proračuna (ISO 13370:2007; EN ISO 13370:2007) HRN EN 13779:2008 Ventilacija u nestambenim zgradama -- Zahtjevi za sustave ventilacije i klimatizacije (EN 13779:2007) HRN EN ISO 13788:2002 Značajke građevnih dijelova i građevnih dijelova zgrada s obzirom na toplinu i vlagu -- Tem-peratura unutarnje površine kojom se izbjegava kritična vlažnost površine i unutarnja kondenzacija -- Metode proračuna (ISO 13788:2001; EN ISO 13788:2001) HRN EN ISO 13789:2008 Toplinske značajke zgrada -- Koeficijenti prijelaza topline transmisijom i ventilacijom -- Me-toda proračuna (ISO 13789:2007; EN ISO 13789:2007) HRN EN ISO 13790:2008 Energetska svojstva zgrada -- Proračun potrebne energije za grijanje i hlađenje prostora (EN ISO 13790:2008) HRN EN ISO 14683:2008 Toplinski mostovi u zgradarstvu -- Linearni koeficijent prolaska topline -- Pojednostavnjene metode i zadane utvrđene vrijednosti (ISO 14683:2007; EN ISO 14683:2007) HRN EN 15193:2008 Energijska svojstva zgrade -- Energijski zahtjevi za rasvjetu (EN 15193:2007) HRN EN 15193:2008/Ispr.1:2011 Energijska svojstva zgrade -- Energijski zahtjevi za rasvjetu (EN 15193:2007/AC:2010) HRN EN 15232:2012 Energijske značajke zgrada -- Utjecaj automatizacije zgrada, nadzor i upravljanje zgradama (EN 15232:2012) HRN EN 15251:2008 Ulazni mikroklimatski parametri za projektiranje i ocjenjivanje energijskih značajka zgrada koji se odnose na kvalitetu zraka, toplinsku lagodnost, osvjetljenje i akustiku (EN 15251:2007)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 3

Lokacija zgrade:

Ulica, kućni broj: Mlinarska cesta br.34

Poštanski broj: Zagreb [10000]

Katastarska općina: Centar [335240]

Katastarska čestica: 333

Kategorija zgrade iz TPRUETZZ prema namjeni zone s najvećim Ak: zgrade za obrazovanje

Namjena zgrade: zgrade za osnovno i srednje obrazovanje (škola)

Vrsta zgrade prema PEPZEC

prema namjeni zone s najvećim Ak: 4. zgrade za obrazovanje

prema složenosti tehničkih sustava: zgrada sa složenim tehničkim sustavom

Nova zgrada: DA

Godina izgradnje: 2020

Etažnost: Pr+1

Meteorološka postaja: ZAGREB GRIČ

Nadmorska visina: 157 mnv (meteorološka postaja); 151 mnv (lokacija zgrade)

Referentna klima: KONTINENTALNA HRVATSKA

Investitor:

Naziv: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

Ulica, kućni broj: MLINARSKA CESTA br.34

Poštanski broj: Zagreb [10000]

Ostali podaci iz projekta:

Naziv zgrade: DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU PRI ŠKOLI ZA MEDICINSKE SESTRE Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Zajednička oznaka projekta: 05-6/19

Projektant: Željka Veseljak, dipl.ing.arh.

Tehnički dnevnik: 26-2019

Geometrijske karakteristike zgrade:

Obujam grijanog dijela, Ve (m³): 6.074,51

Neto obujam, V (m³): 4.010,92

Korisna površina, AK (m²): 903,67

Bruto podna površina, Af (m²): 1.053,97

Vanjska površina grijanog dijela, A (m²): 2.431,22

Faktor oblika, fo (m‾¹): 0,40

Utjecaj toplinskih mostova uzet je u obzir povećanjem koeficijenta prolaska topline, U (W/m2K), svakog građevnog dijela oplošja grijanog dijela zgrade za UTM = 0,05 (W/m2K)

P O D A C I O T E R M O T E H N I Č K I M S U S T A V I M A Z G R A D E

Način grijanja zgrade

lokalno centralno nema X

etažno

Način pripreme potrošne tople vode

lokalno centralno nema X

spremnik protočno

Godina proizvodnje izvora toplinske energije za grijanje

Izvor energije za grijanje zgrade

prirodni plin ukapljeni naftni plin nema X

loživo ulje električna energija

X drvo (cjepanice) drvna biomasa

daljinski izvor ............................

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 4

Izvor energije za pripremu potrošne tople vode

prirodni plin ukapljeni naftni plin nema

X

loživo ulje električna energija

drvo (cjepanice) drvna biomasa

daljinski izvor ............................

Način hlađenja zgrade

lokalno centralno nema X

etažno

Izvori energije koji se koriste za hlađenje zgrade

električna energija ............................ nema X

Vrsta ventilacije prisilna bez sustava povrata to-pline

prisilna sa sustavom po-vrata topline

prirodna X X X

Vrsta i način korištenja sustava s obnovljivim izvorima energije dizalica topline solarni kolektori nema X

biomasa fotonapon

..................................................................................

Meteorološki podaci: Vanjska temperatura i vlaga zraka:

mjesec I II III IV V VI VII VIII IX X XI XII

temperatura, Θe (°C) 2,3 4,4 8,4 13,0 17,7 21,0 22,8 22,4 17,3 12,5 7,6 2,6

vlaga, φe (°C) 76,0 67,0 62,0 60,0 62,0 64,0 63,0 65,0 71,0 76,0 78,0 81,0

Gustoća globalnog sunčeva zračenja, I (MJ/m²)

nagib (°) orijentacija I II III IV V VI VII VIII IX X XI XII

0 Hor 108 164 329 456 593 629 671 561 421 259 125 82

15 S 131 192 367 479 597 622 670 582 468 308 152 97

15 SE 124 184 356 473 596 624 671 577 455 293 144 92

15 SW 124 184 356 473 596 624 671 577 455 293 144 92

15 E 108 164 328 452 586 621 663 556 419 259 125 81

15 W 108 164 328 452 586 621 663 556 419 259 125 81

15 NE 92 143 294 425 570 613 649 528 376 220 106 70

15 NW 82 143 277 425 558 613 635 528 355 220 94 70

15 N 82 130 277 412 558 601 635 513 355 199 94 63

30 S 148 212 389 481 578 592 643 577 493 342 172 109

30 SE 135 196 370 475 582 602 652 574 473 316 156 100

30 SW 135 196 370 475 582 602 652 574 473 316 156 100

30 E 107 162 322 440 568 600 641 541 412 256 124 80

30 W 107 162 322 440 568 600 641 541 412 256 124 80

30 NE 80 124 259 384 527 572 601 480 328 188 92 62

30 NW 73 124 215 384 493 572 560 480 273 188 80 62

30 N 73 101 215 349 493 537 560 439 273 139 80 59

45 S 158 221 392 463 536 541 591 547 493 359 184 116

45 SE 140 200 370 459 550 562 612 551 471 324 162 103

45 SW 140 200 370 459 550 562 612 551 471 324 162 103

45 E 104 157 310 420 538 566 608 516 398 249 121 78

45 W 104 157 310 420 538 566 608 516 398 249 121 78

45 NE 69 109 229 342 473 516 538 427 287 163 77 55

45 NW 69 109 167 342 407 516 459 427 190 163 76 55

45 N 69 95 167 274 407 449 459 347 190 125 76 55

60 S 162 221 378 424 474 471 516 494 469 359 188 118

60 SE 139 195 354 428 501 506 554 509 449 318 161 102

60 SW 139 195 354 428 501 506 554 509 449 318 161 102

60 E 98 147 291 391 496 521 561 479 374 236 114 73

60 W 98 147 291 391 496 521 561 479 374 236 114 73

60 NE 63 89 197 305 421 458 478 379 251 129 69 51

60 NW 63 89 153 305 307 458 341 379 161 129 69 51

60 N 63 87 153 204 307 344 341 246 161 116 69 51

75 S 157 210 346 368 396 386 425 421 422 340 182 114

75 SE 131 183 324 381 436 436 479 450 410 298 153 96

75 SW 131 183 324 381 436 436 479 450 410 298 153 96

75 E 90 134 264 353 445 466 503 432 342 217 104 66

75 W 90 134 264 353 445 466 503 432 342 217 104 66

75 NE 56 79 151 256 368 404 420 325 190 106 62 45

75 NW 56 79 139 256 229 404 235 325 148 106 62 45

75 N 56 79 139 181 229 236 235 206 148 106 62 45

90 S 145 189 298 299 309 296 324 334 356 305 167 106

90 SE 119 163 283 324 363 359 395 379 355 265 138 87

90 SW 119 163 283 324 363 359 395 379 355 265 138 87

90 E 79 118 233 308 386 403 436 377 301 192 92 58

90 W 79 118 233 308 386 403 436 377 301 192 92 58

90 NE 49 69 124 183 286 323 328 237 136 95 55 39

90 NW 49 69 124 183 206 323 214 237 135 95 55 39

90 N 49 69 124 163 206 214 214 186 135 95 55 39

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 5

POPIS GRAĐEVNIH DIJELOVA ZGRADE

Vanjski zidovi

Z1 Vanjski ventilirani zid u prizemlju, U=0,23 W/m2K, (Udop=0,30 W/m2K) 1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=25(cm), λ=2,6 (W/mK), r=32,5 (m), m'=625 (kg/m2)

3 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa voalom FPL 035 GVB), d=14(cm), λ=0,035 (W/mK), r=0,154 (m), m'=7 (kg/m2)

4 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Z1 Vanjski ventilirani zid u prizemlju - sokl, U=0,26 W/m2K, (Udop=0,30 W/m2K) 1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=25(cm), λ=2,6 (W/mK), r=32,5 (m), m'=625 (kg/m2)

3 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,15(cm), λ=0,26 (W/mK), r=135 (m), m'=2,4 (kg/m2)

4 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

5 ekstrudirani polistiren u pločama XPS, d=12(cm), λ=0,033 (W/mK), r=18 (m), m'=4,8 (kg/m2)

6 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom, d=0,3(cm), λ=0,7 (W/mK), r=0,6 (m), m'=5,4 (kg/m2)

7 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Z2 Vanjski ventilirani zid na katu, U=0,21 W/m2K, (Udop=0,30 W/m2K) 1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=25(cm), λ=2,6 (W/mK), r=32,5 (m), m'=625 (kg/m2)

3 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa voalom FPL 035 GVB), d=16(cm), λ=0,035 (W/mK), r=0,176 (m), m'=8 (kg/m2)

4 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Z2 Vanjski ventilirani zid na katu - sokl, U=0,22 W/m2K, (Udop=0,30 W/m2K) 1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=25(cm), λ=2,6 (W/mK), r=32,5 (m), m'=625 (kg/m2)

3 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,15(cm), λ=0,26 (W/mK), r=135 (m), m'=2,4 (kg/m2)

4 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

5 ekstrudirani polistiren u pločama XPS, d=14(cm), λ=0,033 (W/mK), r=21 (m), m'=5,6 (kg/m2)

6 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom, d=0,3(cm), λ=0,7 (W/mK), r=0,6 (m), m'=5,4 (kg/m2)

7 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Z2a Vanjski ventilirani zid na katu – dvorana za ergonomiju, U=0,16 W/m2K, (Udop=0,30 W/m2K) 1 Drvo - letvice (500), d=1,6(cm), λ=0,13 (W/mK), r=0,8 (m), m'=8 (kg/m2)

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL), d=5(cm), λ=0,038 (W/mK), r=0,06 (m), m'=0,75 (kg/m2)

3 2.01 - armirani beton (2500), d=30(cm), λ=2,6 (W/mK), r=39 (m), m'=750 (kg/m2)

4 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa voalom FPL 035 GVB), d=16(cm), λ=0,035 (W/mK), r=0,176 (m), m'=8 (kg/m2)

5 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Z2b Vanjski ventilirani zid na katu – dio uz sanitarije, U=0,15 W/m2K, (Udop=0,30 W/m2K) 1 4.01 - gipskartonske ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=22,5 (kg/m2)

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W), d=5(cm), λ=0,037 (W/mK), r=0,06 (m), m'=0,75 (kg/m2)

3 4.01 - gipskartonske ploče, d=1,25(cm), λ=0,25 (W/mK), r=0,1 (m), m'=11,25 (kg/m2)

4 Neprovjetravani sloj zraka - toplinski tok uvis d=100mm, d=10(cm), λ=0,625 (W/mK), r=0,1 (m), m'=0,1 (kg/m2)

5 2.01 - armirani beton (2500), d=20(cm), λ=2,6 (W/mK), r=26 (m), m'=500 (kg/m2)

6 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa voalom FPL 035 GVB), d=16(cm), λ=0,035 (W/mK), r=0,176 (m), m'=8 (kg/m2)

7 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 6

Z2b Vanjski ventilirani zid na katu – dio uz sanitarije - sokl, U=0,16 W/m2K, (Udop=0,30 W/m2K) 1 4.01 - gipskartonske ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=22,5 (kg/m2)

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W), d=5(cm), λ=0,037 (W/mK), r=0,06 (m), m'=0,75 (kg/m2)

3 4.01 - gipskartonske ploče, d=1,25(cm), λ=0,25 (W/mK), r=0,1 (m), m'=11,25 (kg/m2)

4 Neprovjetravani sloj zraka - toplinski tok uvis d=100mm, d=10(cm), λ=0,625 (W/mK), r=0,1 (m), m'=0,1 (kg/m2)

5 2.01 - armirani beton (2500), d=20(cm), λ=2,6 (W/mK), r=26 (m), m'=500 (kg/m2)

6 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,15(cm), λ=0,26 (W/mK), r=135 (m), m'=2,4 (kg/m2)

7 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

8 ekstrudirani polistiren u pločama XPS, d=14(cm), λ=0,033 (W/mK), r=21 (m), m'=5,6 (kg/m2)

9 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom, d=0,3(cm), λ=0,7 (W/mK), r=0,6 (m), m'=5,4 (kg/m2)

10 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Z3 Vanjski zid s ETICS fasadom – zapadno pročelje dvorane, U=0,16 W/m2K, (Udop=0,30 W/m2K) 1 Drvo - letvice (500), d=1,6(cm), λ=0,13 (W/mK), r=0,8 (m), m'=8 (kg/m2)

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL), d=5(cm), λ=0,038 (W/mK), r=0,06 (m), m'=0,75 (kg/m2)

3 2.01 - armirani beton (2500), d=30(cm), λ=2,6 (W/mK), r=39 (m), m'=750 (kg/m2)

4 mineralna vuna (MW) fasadne ploče s l=0,035 (Knauf Insulation FKD S Thermal), d=16(cm), λ=0,035 (W/mK), r=0,192 (m), m'=18,4 (kg/m2)

5 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom, d=0,3(cm), λ=0,7 (W/mK), r=0,6 (m), m'=5,4 (kg/m2)

6 Silikatna žbuka 1,5, d=0,2(cm), λ=0,87 (W/mK), r=0,1 (m), m'=3,7 (kg/m2)

Z3 Vanjski zid s ETICS fasadom – zapadno pročelje dvorane - sokl, U=0,17 W/m2K, (Udop=0,30 W/m2K)

1 Drvo - letvice (500), d=1,6(cm), λ=0,13 (W/mK), r=0,8 (m), m'=8 (kg/m2)

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL), d=5(cm), λ=0,038 (W/mK), r=0,06 (m), m'=0,75 (kg/m2)

3 2.01 - armirani beton (2500), d=30(cm), λ=2,6 (W/mK), r=39 (m), m'=750 (kg/m2)

4 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,15(cm), λ=0,26 (W/mK), r=135 (m), m'=2,4 (kg/m2)

5 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

6 ekstrudirani polistiren u pločama XPS, d=14(cm), λ=0,033 (W/mK), r=21 (m), m'=5,6 (kg/m2)

7 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom, d=0,3(cm), λ=0,7 (W/mK), r=0,6 (m), m'=5,4 (kg/m2)

8 Silikatna žbuka 1,5, d=0,2(cm), λ=0,87 (W/mK), r=0,1 (m), m'=3,7 (kg/m2)

Prozori

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33, Uw=1,49 W/m2K, (Uw,dop=1,60 W/m2K) Uf=2,40 W/m2K, Ug=1,10 W/m2K, Ff=0,70, gokom.=0,33, Fc,H=1,00, Fc,C=1,00

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo / mutno nepro-zirno staklo s g=60, Uw=1,49 W/m2K, (Uw,dop=1,60 W/m2K) Uf=2,40 W/m2K, Ug=1,10 W/m2K, Ff=0,70, gokom.=0,60, Fc,H=1,00, Fc,C=1,00

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo + unutarnje ža-luzine, Uw=1,49 W/m2K, (Uw,dop=1,60 W/m2K) Uf=2,40 W/m2K, Ug=1,10 W/m2K, Ff=0,70, gokom.=0,60, Fc,H=1,00, Fc,C=0,75

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo + unutarnje ža-luzine + streha, Uw=1,49 W/m2K, (Uw,dop=1,60 W/m2K) Uf=2,40 W/m2K, Ug=1,10 W/m2K, Ff=0,70, gokom.=0,60, Fc,H=1,00, Fc,C=0,38

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo + vanjski briso-leji, Uw=1,49 W/m2K, (Uw,dop=1,60 W/m2K) Uf=2,40 W/m2K, Ug=1,10 W/m2K, Ff=0,70, gokom.=0,60, Fc,H=1,00, Fc,C=0,30

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 7

Ravni i kosi krov iznad grijanog prostora

K1 Ravni zeleni laki krov dvorane za ergonomiju, U=0,10 W/m2K, (Udop=0,25 W/m2K) 1 Drvo - letvice (500), d=1,6(cm), λ=0,13 (W/mK), r=0,8 (m), m'=8 (kg/m2)

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL), d=5(cm), λ=0,038 (W/mK), r=0,06 (m), m'=0,75 (kg/m2)

3 Neprovjetravani sloj zraka - toplinski tok uvis d=300mm, d=30(cm), λ=1,875 (W/mK), r=0,3 (m), m'=0,3 (kg/m2)

4 čelični lim, d=0,1(cm), λ=58,5 (W/mK), r=600 (m), m'=7,8 (kg/m2)

5 parna brana - Knauf Insulation LDS 100 AL-PE aluminizirana parna brana, d=0,02(cm), λ=203 (W/mK), r=70 (m), m'=0,36 (kg/m2)

6 mineralna vuna (MW) krovne ploče s l=0,038 (Knauf Insulation Smart Roof THERMAL), d=15(cm), λ=0,036 (W/mK), r=0,18 (m), m'=13,5 (kg/m2)

7 mineralna vuna (MW) krovne ploče s l=0,038 (Knauf Insulation Smart Roof TOP), d=10(cm), λ=0,038 (W/mK), r=0,12 (m), m'=13,5 (kg/m2)

8 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,18(cm), λ=0,26 (W/mK), r=162 (m), m'=2,88 (kg/m2)

9 ekstrudirani polistiren u pločama XPS, d=5(cm), λ=0,033 (W/mK), r=7,5 (m), m'=2 (kg/m2)

K2 Ravni neprohodni krov, U=0,11 W/m2K, (Udop=0,25 W/m2K) 1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=16(cm), λ=2,6 (W/mK), r=20,8 (m), m'=400 (kg/m2)

3 2.12 - beton s laganim agregatom (1200), d=4(cm), λ=0,62 (W/mK), r=4 (m), m'=48 (kg/m2)

4 parna brana - bitumenska traka 4 mm s uloškom Al folije d= 0,2 mm, d=0,02(cm), λ=203 (W/mK), r=160 (m), m'=0,54 (kg/m2)

5 ekstrudirani polistiren u pločama XPS, d=30(cm), λ=0,033 (W/mK), r=45 (m), m'=12 (kg/m2)

6 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

7 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,15(cm), λ=0,26 (W/mK), r=135 (m), m'=2,4 (kg/m2)

8 geotekstili (na bazi propilena), d=0,02 (cm), (* sloj ne ulazi u proračun)

9 oblutci - zaštitni sloj oblutaka 16-32, d=7 (cm), (* sloj ne ulazi u proračun)

K2a Ravni neprohodni krov, smještaj strojarskih uređaja – podnožja uređaja i opreme, U=0,11 W/m2K, (Udop=0,25 W/m2K)

1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=16(cm), λ=2,6 (W/mK), r=20,8 (m), m'=400 (kg/m2)

3 2.12 - beton s laganim agregatom (1200), d=4(cm), λ=0,62 (W/mK), r=4 (m), m'=48 (kg/m2)

4 parna brana - bitumenska traka 4 mm s uloškom Al folije d= 0,2 mm, d=0,02(cm), λ=203 (W/mK), r=160 (m), m'=0,54 (kg/m2)

5 ekstrudirani polistiren u pločama XPS, d=30(cm), λ=0,033 (W/mK), r=45 (m), m'=12 (kg/m2)

6 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

7 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,15(cm), λ=0,26 (W/mK), r=135 (m), m'=2,4 (kg/m2)

8 geotekstili (na bazi propilena), d=0,02 (cm), (* sloj ne ulazi u proračun)

9 Ethafoam 222-E - folija od ekstrudiranog polietilena (Dow Chemical), d=1 (cm), (* sloj ne ulazi u proračun)

10 2.01 - armirani beton (2500), d=12 (cm), (* sloj ne ulazi u proračun)

Stropovi iznad vanjskog zraka

M2 Međukatna konstrukcija grijanih prostora iznad otvorenog– pod dvorane za ergonomiju, U=0,16 W/m2K, (Udop=0,25 W/m2K)

1 PVC homogen, d=0,4(cm), λ=0,23 (W/mK), r=40 (m), m'=5,6 (kg/m2)

2 Šperploče lake, d=1,8(cm), λ=0,14 (W/mK), r=1,08 (m), m'=9,9 (kg/m2)

3 4.05 - drvo - meko - crnogorica, d=3,5(cm), λ=0,15 (W/mK), r=2,45 (m), m'=19,25 (kg/m2)

4 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

5 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

6 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

7 STIROPOR EPS 150 (prema HRN EN 13163), d=1(cm), λ=0,036 (W/mK), r=0,7 (m), m'=0,25 (kg/m2)

8 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

9 2.01 - armirani beton (2500), d=22(cm), λ=2,6 (W/mK), r=28,6 (m), m'=550 (kg/m2)

10 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa voalom FPL 035 GVB), d=16(cm), λ=0,035 (W/mK), r=0,176 (m), m'=8 (kg/m2)

11 dobro ventilirani zračni sloj, d=4 (cm), (* sloj ne ulazi u proračun)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 8

Zidovi prema negrijanim prostorijama i negrijanom stubištu temperature više od 0°C

UZ2 Nosivi unutarnji armiranobetonski zid grijanog prostora prema negrijanom prostoru, U=0,31 W/m2K, (Udop=0,40 W/m2K)

1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=30(cm), λ=2,6 (W/mK), r=39 (m), m'=750 (kg/m2)

3 mineralna vuna (MW) fasadne ploče s l=0,035 (Knauf Insulation FKD S Thermal), d=10(cm), λ=0,035 (W/mK), r=0,12 (m), m'=11,5 (kg/m2)

4 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom, d=0,3(cm), λ=0,7 (W/mK), r=0,6 (m), m'=5,4 (kg/m2)

5 Silikatna žbuka 1,5, d=0,2(cm), λ=0,87 (W/mK), r=0,1 (m), m'=3,7 (kg/m2)

UZ3 Laka pregradna stijena između grijanog i negrijanog prostora d=15,0cm (prema spremištu u pri-zemlju), laka pregradna stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm, U=0,32 W/m2K, (Udop=0,40 W/m2K)

1 Knauf Diamant ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=25,6 (kg/m2)

2 parna brana - Knauf Insulation LDS 100 AL-PE aluminizirana parna brana, d=0,02(cm), λ=203 (W/mK), r=70 (m), m'=0,36 (kg/m2)

3 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W), d=10(cm), λ=0,037 (W/mK), r=0,12 (m), m'=1,5 (kg/m2)

4 Knauf Diamant ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=25,6 (kg/m2)

Stropovi iznad negrijanih prostorija i negrijanog stubišta temperature više od 0°C

M6 Međukatna konstrukcija grijanog prostora na katu iznad negrijane prostorije prizemlja, U=0,26 W/m2K, (Udop=0,40 W/m2K)

1 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

2 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

3 STIROPOR EPS 150 (prema HRN EN 13163), d=5(cm), λ=0,036 (W/mK), r=3,5 (m), m'=1,25 (kg/m2)

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

5 2.01 - armirani beton (2500), d=22(cm), λ=2,6 (W/mK), r=28,6 (m), m'=550 (kg/m2)

6 mineralna vuna (MW) fasadne ploče s l=0,035 (Knauf Insulation FKD S Thermal), d=5(cm), λ=0,035 (W/mK), r=0,06 (m), m'=5,75 (kg/m2)

7 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom, d=0,3(cm), λ=0,7 (W/mK), r=0,6 (m), m'=5,4 (kg/m2)

8 Silikatna žbuka 1,5, d=0,2(cm), λ=0,87 (W/mK), r=0,1 (m), m'=3,7 (kg/m2)

Zidovi prema tlu

PZ1 Armiranobetonski zid grijanih prostorija prema tlu, U=0,26 W/m2K, (Udop=0,40 W/m2K) 1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=30(cm), λ=2,6 (W/mK), r=39 (m), m'=750 (kg/m2)

3 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO, d=0,15(cm), λ=0,26 (W/mK), r=135 (m), m'=2,4 (kg/m2)

4 geotekstil (na bazi propilena), d=0,02 (cm), (* sloj ne ulazi u proračun)

5 ekstrudirani polistiren u pločama XPS, d=12(cm), λ=0,033 (W/mK), r=18 (m), m'=4,8 (kg/m2)

6 PEHD folija - drenažna traka s bradavicama 1cm/1mm, d=0,1 (cm), (* sloj ne ulazi u proračun)

Podovi na tlu

P1 Pod na tlu grijanog prostora u prizemlju, U=0,28 W/m2K, (Udop=0,40 W/m2K) 1 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

2 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

3 STIROPOR EPS 150 (prema HRN EN 13163), d=10(cm), λ=0,036 (W/mK), r=7 (m), m'=2,5 (kg/m2)

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

5 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

6 5.01 - bitumenska traka s uloškom staklenog voala, d=1(cm), λ=0,23 (W/mK), r=500 (m), m'=11 (kg/m2)

7 2.01 - armirani beton (2500), d=20 (cm), (* sloj ne ulazi u proračun)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 9

P2 Pod na tlu u sanitarijama grijanog prostora u prizemlju, U=0,28 W/m2K, (Udop=0,40 W/m2K)

1 4.03 - keramičke pločice, d=0,8(cm), λ=1,3 (W/mK), r=1,6 (m), m'=18,4 (kg/m2)

2 Građevinsko ljepilo, d=0,2(cm), λ=1 (W/mK), r=0,1 (m), m'=3,2 (kg/m2)

3 polimercementni hidroizolacijski premaz, d=0,2(cm), λ=0,7 (W/mK), r=0,4 (m), m'=2,2 (kg/m2)

4 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

5 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

6 STIROPOR EPS 150 (prema HRN EN 13163), d=10(cm), λ=0,036 (W/mK), r=7 (m), m'=2,5 (kg/m2)

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

8 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

9 5.01 - bitumenska traka s uloškom staklenog voala, d=1(cm), λ=0,23 (W/mK), r=500 (m), m'=11 (kg/m2)

10 2.01 - armirani beton (2500), d=20 (cm), (* sloj ne ulazi u proračun)

P3 Pod na tlu u sanitarijama grijanog prostora u prizemlju + podno grijanje, U=0,28 W/m2K, (U-dop=0,40 W/m2K)

1 4.03 - keramičke pločice, d=0,8(cm), λ=1,3 (W/mK), r=1,6 (m), m'=18,4 (kg/m2)

2 Građevinsko ljepilo, d=0,2(cm), λ=1 (W/mK), r=0,1 (m), m'=3,2 (kg/m2)

3 polimercementni hidroizolacijski premaz, d=0,2(cm), λ=0,7 (W/mK), r=0,4 (m), m'=2,2 (kg/m2)

4 Cementni estrih, d=6,5(cm), λ=1,4 (W/mK), r=1,95 (m), m'=143 (kg/m2)

5 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

6 STIROPOR EPS 150 (prema HRN EN 13163), d=10(cm), λ=0,036 (W/mK), r=7 (m), m'=2,5 (kg/m2)

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

8 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

9 5.01 - bitumenska traka s uloškom staklenog voala, d=1(cm), λ=0,23 (W/mK), r=500 (m), m'=11 (kg/m2)

10 2.01 - armirani beton (2500), d=20 (cm), (* sloj ne ulazi u proračun)

P5 Pod na tlu grijanog prostora na katu, U=0,27 W/m2K, (Udop=0,40 W/m2K) 1 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

2 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

3 STIROPOR EPS 150 (prema HRN EN 13163), d=5(cm), λ=0,036 (W/mK), r=3,5 (m), m'=1,25 (kg/m2)

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

5 2.01 - armirani beton (2500), d=22(cm), λ=2,6 (W/mK), r=28,6 (m), m'=550 (kg/m2)

6 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

7 ekstrudirani polistiren u pločama XPS, d=5(cm), λ=0,033 (W/mK), r=7,5 (m), m'=2 (kg/m2)

8 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

9 5.05 - polimerna hidroizolacijska traka na bazi PVC-P, d=0,15(cm), λ=0,14 (W/mK), r=150 (m), m'=1,8 (kg/m2)

10 geotekstili (na bazi propilena), d=0,02 (cm), (* sloj ne ulazi u proračun)

11 donja betonska podloga, armirana i zaglađena, d=10 (cm), (* sloj ne ulazi u proračun)

P6 Pod na tlu u sanitarijama grijanog prostora na katu + podno grijanje, U=0,26 W/m2K, (Udop=0,40 W/m2K)

1 4.03 - keramičke pločice, d=0,8(cm), λ=1,3 (W/mK), r=1,6 (m), m'=18,4 (kg/m2)

2 Građevinsko ljepilo, d=0,2(cm), λ=1 (W/mK), r=0,1 (m), m'=3,2 (kg/m2)

3 polimercementni hidroizolacijski premaz, d=0,2(cm), λ=0,7 (W/mK), r=0,4 (m), m'=2,2 (kg/m2)

4 Cementni estrih, d=6,5(cm), λ=1,4 (W/mK), r=1,95 (m), m'=143 (kg/m2)

5 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

6 STIROPOR EPS 150 (prema HRN EN 13163), d=5(cm), λ=0,036 (W/mK), r=3,5 (m), m'=1,25 (kg/m2)

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

8 2.01 - armirani beton (2500), d=22(cm), λ=2,6 (W/mK), r=28,6 (m), m'=550 (kg/m2)

9 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

10 ekstrudirani polistiren u pločama XPS, d=5(cm), λ=0,033 (W/mK), r=7,5 (m), m'=2 (kg/m2)

11 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

12 5.05 - polimerna hidroizolacijska traka na bazi PVC-P, d=0,15(cm), λ=0,14 (W/mK), r=150 (m), m'=1,8 (kg/m2)

13 geotekstili (na bazi propilena), d=0,02 (cm), (* sloj ne ulazi u proračun)

14 donja betonska podloga, armirana i zaglađena, d=10 (cm), (* sloj ne ulazi u proračun)

Vanjska vrata, s neprozirnim vratnim krilom

V1 Vanjska vrata grijanih prostora - neprozirno vratno krilo, U=2,00 W/m2K, (Udop=2,00 W/m2K)

Vrata prema negrijanom stubištu, s neprozirnim vratnim krilom

V2 Vrata grijanog prostora prema negrijanom prostoru (spremište u prizemlju), U=2,00 W/m2K, (U-dop=2,00 W/m2K)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 10

Neprozirni građevni dijelovi u negrijanom prostoru

P4 Pod na tlu negrijanog prostora u prizemlju, U=0,40 W/m2K 1 4.03 - keramičke pločice, d=0,8(cm), λ=1,3 (W/mK), r=1,6 (m), m'=18,4 (kg/m2)

2 Građevinsko ljepilo, d=0,2(cm), λ=1 (W/mK), r=0,1 (m), m'=3,2 (kg/m2)

3 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

4 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

5 STIROPOR EPS 150 (prema HRN EN 13163), d=6(cm), λ=0,036 (W/mK), r=4,2 (m), m'=1,5 (kg/m2)

6 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

7 geotekstili (na bazi propilena), d=0,02(cm), λ=0,25 (W/mK), r=0,0002 (m), m'=0,24 (kg/m2)

8 5.01 - bitumenska traka s uloškom staklenog voala, d=1(cm), λ=0,23 (W/mK), r=500 (m), m'=11 (kg/m2)

9 2.01 - armirani beton (2500), d=20 (cm), (* sloj ne ulazi u proračun)

Ostali građevni dijelovi

M1 Međukatna konstrukcija između grijanih prostora – pod dvorane za ergonomiju, U=0,54 W/m2K 1 PVC homogen, d=0,4(cm), λ=0,23 (W/mK), r=40 (m), m'=5,6 (kg/m2)

2 Šperploče lake, d=1,8(cm), λ=0,14 (W/mK), r=1,08 (m), m'=9,9 (kg/m2)

3 4.05 - drvo - meko - crnogorica, d=3,5(cm), λ=0,15 (W/mK), r=2,45 (m), m'=19,25 (kg/m2)

4 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

5 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

6 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

7 STIROPOR EPS 150 (prema HRN EN 13163), d=1(cm), λ=0,036 (W/mK), r=0,7 (m), m'=0,25 (kg/m2)

8 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

9 2.01 - armirani beton (2500), d=22(cm), λ=2,6 (W/mK), r=28,6 (m), m'=550 (kg/m2)

10 Neprovjetravani sloj zraka - toplinski tok vodoravan d=50mm, d=5(cm), λ=0,278 (W/mK), r=0,05 (m), m'=0,05 (kg/m2)

11 4.01 - gipskartonske ploče, d=1,25(cm), λ=0,25 (W/mK), r=0,1 (m), m'=11,25 (kg/m2)

M3 Međukatna konstrukcija između grijanih prostora (hodnik), U=0,39 W/m2K 1 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

2 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

3 STIROPOR EPS 150 (prema HRN EN 13163), d=5(cm), λ=0,036 (W/mK), r=3,5 (m), m'=1,25 (kg/m2)

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

5 2.01 - armirani beton (2500), d=22(cm), λ=2,6 (W/mK), r=28,6 (m), m'=550 (kg/m2)

6 Neprovjetravani sloj zraka - toplinski tok vodoravan d=50mm, d=5(cm), λ=0,278 (W/mK), r=0,05 (m), m'=0,05 (kg/m2)

7 4.01 - gipskartonske ploče, d=1,25(cm), λ=0,25 (W/mK), r=0,1 (m), m'=11,25 (kg/m2)

M4 Međukatna konstrukcija u sanitarijama između grijanih prostora, U=0,39 W/m2K 1 4.03 - keramičke pločice, d=0,8(cm), λ=1,3 (W/mK), r=1,6 (m), m'=18,4 (kg/m2)

2 Građevinsko ljepilo, d=0,2(cm), λ=1 (W/mK), r=0,1 (m), m'=3,2 (kg/m2)

3 polimercementni hidroizolacijski premaz, d=0,2(cm), λ=0,7 (W/mK), r=0,4 (m), m'=2,2 (kg/m2)

4 Cementni estrih, d=4(cm), λ=1,4 (W/mK), r=1,2 (m), m'=88 (kg/m2)

5 Polietilen / politen, mala gustoća, d=0,02(cm), λ=0,33 (W/mK), r=20 (m), m'=0,184 (kg/m2)

6 STIROPOR EPS 150 (prema HRN EN 13163), d=5(cm), λ=0,036 (W/mK), r=3,5 (m), m'=1,25 (kg/m2)

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge, d=2(cm), λ=0,035 (W/mK), r=1,2 (m), m'=0,3 (kg/m2)

8 2.01 - armirani beton (2500), d=22(cm), λ=2,6 (W/mK), r=28,6 (m), m'=550 (kg/m2)

9 Neprovjetravani sloj zraka - toplinski tok vodoravan d=50mm, d=5(cm), λ=0,278 (W/mK), r=0,05 (m), m'=0,05 (kg/m2)

10 4.01 - gipskartonske ploče, d=1,25(cm), λ=0,25 (W/mK), r=0,1 (m), m'=11,25 (kg/m2)

UZ1 Nosivi unutarnji armiranobetonski zid, U=2,59 W/m2K 1 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

2 2.01 - armirani beton (2500), d=30(cm), λ=2,6 (W/mK), r=39 (m), m'=750 (kg/m2)

3 cementna glet masa, d=0,5(cm), λ=1 (W/mK), r=0,05 (m), m'=7,5 (kg/m2)

UZ4 Laka pregradna stijena s poboljšanim zvučnim karakteristikama d=15,0cm (između dvije više-namjenske prostorije za edukaciju i prema drugom prostorijama, laki zid dvorane prema drugim pros-torijama, zidovi kabineta), U=0,32 W/m2K

1 Knauf Diamant ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=25,6 (kg/m2)

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W), d=10(cm), λ=0,037 (W/mK), r=0,12 (m), m'=1,5 (kg/m2)

3 Knauf Diamant ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=25,6 (kg/m2)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 11

UZ5 Unutarnji laki pregradni zid (sanitarije i sl.), laka pregradna stijena od gipskartonskih ploča na metalnoj potkonstrukciji - debljine 10,0 cm, U=0,55 W/m2K

1 4.01 - gipskartonske ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=22,5 (kg/m2)

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W), d=5(cm), λ=0,037 (W/mK), r=0,06 (m), m'=0,75 (kg/m2)

3 4.01 - gipskartonske ploče, d=2,5(cm), λ=0,25 (W/mK), r=0,2 (m), m'=22,5 (kg/m2)

Građevni dijelovi zadovoljavaju zahtjeve tehničkog propisa!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 12

Proračun građevnog dijela zgrade

Z1 Vanjski ventilirani zid u prizemlju Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 25,00 1000 2500 2,600 32,5

3 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa vo-alom FPL 035 GVB)

14,00 1030 50 0,035 0,2

4 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 43,50 33,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 4,27 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,23 + 0,00 = 0,23 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,970 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 13

Proračun građevnog dijela zgrade

Z1 Vanjski ventilirani zid u prizemlju - sokl Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 25,00 1000 2500 2,600 32,5

3 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,15 960 1600 0,260 135,0

4 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

5 ekstrudirani polistiren u pločama XPS 12,00 1450 40 0,033 18,0

6 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom 0,30 1000 1800 0,700 0,6

7 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 41,97 186,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,92 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,26 + 0,00 = 0,26 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,967 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 14

Proračun građevnog dijela zgrade

Z2 Vanjski ventilirani zid na katu Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 25,00 1000 2500 2,600 32,5

3 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa vo-alom FPL 035 GVB)

16,00 1030 50 0,035 0,2

4 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 45,50 33,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 4,84 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,21 + 0,00 = 0,21 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,973 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 15

Proračun građevnog dijela zgrade

Z2 Vanjski ventilirani zid na katu - sokl Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 25,00 1000 2500 2,600 32,5

3 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,15 960 1600 0,260 135,0

4 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

5 ekstrudirani polistiren u pločama XPS 14,00 1450 40 0,033 21,0

6 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom 0,30 1000 1800 0,700 0,6

7 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 43,97 189,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 4,52 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,22 + 0,00 = 0,22 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,971 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 16

Proračun građevnog dijela zgrade

Z2a Vanjski ventilirani zid na katu – dvorana za ergonomiju Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Drvo - letvice (500) 1,60 1600 500 0,130 0,8

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL) 5,00 1030 15 0,038 0,1

3 2.01 - armirani beton (2500) 30,00 1000 2500 2,600 39,0

4 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa vo-alom FPL 035 GVB)

16,00 1030 50 0,035 0,2

5 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 56,60 40,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 6,30 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,16 + 0,00 = 0,16 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,979 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 17

Proračun građevnog dijela zgrade

Z2b Vanjski ventilirani zid na katu – dio uz sanitarije Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.01 - gipskartonske ploče 2,50 900 900 0,250 0,2

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W) 5,00 1030 15 0,037 0,1

3 4.01 - gipskartonske ploče 1,25 900 900 0,250 0,1

4 Neprovjetravani sloj zraka - toplinski tok uvis d=100mm 10,00 1005 1 0,625 0,1

5 2.01 - armirani beton (2500) 20,00 1000 2500 2,600 26,0

6 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa vo-alom FPL 035 GVB)

16,00 1030 50 0,035 0,2

7 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 58,75 27,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 6,48 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,15 + 0,00 = 0,15 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,980 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 18

Proračun građevnog dijela zgrade

Z2b Vanjski ventilirani zid na katu – dio uz sanitarije - sokl Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.01 - gipskartonske ploče 2,50 900 900 0,250 0,2

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W) 5,00 1030 15 0,037 0,1

3 4.01 - gipskartonske ploče 1,25 900 900 0,250 0,1

4 Neprovjetravani sloj zraka - toplinski tok uvis d=100mm 10,00 1005 1 0,625 0,1

5 2.01 - armirani beton (2500) 20,00 1000 2500 2,600 26,0

6 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,15 960 1600 0,260 135,0

7 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

8 ekstrudirani polistiren u pločama XPS 14,00 1450 40 0,033 21,0

9 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom 0,30 1000 1800 0,700 0,6

10 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 57,22 183,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 6,16 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,16 + 0,00 = 0,16 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,979 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 19

Proračun građevnog dijela zgrade

Z3 Vanjski zid s ETICS fasadom – zapadno pročelje dvorane Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Drvo - letvice (500) 1,60 1600 500 0,130 0,8

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL) 5,00 1030 15 0,038 0,1

3 2.01 - armirani beton (2500) 30,00 1000 2500 2,600 39,0

4 mineralna vuna (MW) fasadne ploče s l=0,035 (Knauf Insulation FKD S Thermal)

16,00 1030 115 0,035 0,2

5 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom 0,30 1000 1800 0,700 0,6

6 Silikatna žbuka 1,5 0,20 1050 1850 0,870 0,1

Ukupno: 53,10 41,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 6,30 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,16 + 0,00 = 0,16 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,979 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 20

Proračun građevnog dijela zgrade

Z3 Vanjski zid s ETICS fasadom – zapadno pročelje dvorane - sokl Građevni dio: Vanjski zidovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Drvo - letvice (500) 1,60 1600 500 0,130 0,8

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL) 5,00 1030 15 0,038 0,1

3 2.01 - armirani beton (2500) 30,00 1000 2500 2,600 39,0

4 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,15 960 1600 0,260 135,0

5 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

6 ekstrudirani polistiren u pločama XPS 14,00 1450 40 0,033 21,0

7 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom 0,30 1000 1800 0,700 0,6

8 Silikatna žbuka 1,5 0,20 1050 1850 0,870 0,1

Ukupno: 51,27 197,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 5,98 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,17 + 0,00 = 0,17 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,30 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,978 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 21

Proračun građevnog dijela zgrade

K1 Ravni zeleni laki krov dvorane za ergonomiju Građevni dio: Ravni i kosi krov iznad grijanog prostora

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Drvo - letvice (500) 1,60 1600 500 0,130 0,8

2 mineralna vuna (MW) filc s l=0,038 (KI ECOSE filc DECIBEL) 5,00 1030 15 0,038 0,1

3 Neprovjetravani sloj zraka - toplinski tok uvis d=300mm 30,00 1005 1 1,875 0,3

4 čelični lim 0,10 460 7800 58,500 600,0

5 parna brana - Knauf Insulation LDS 100 AL-PE aluminizirana parna brana 0,02 940 1800 203,000 70,0

6 mineralna vuna (MW) krovne ploče s l=0,038 (Knauf Insulation Smart Roof THERMAL)

15,00 1030 90 0,036 0,2

7 mineralna vuna (MW) krovne ploče s l=0,038 (Knauf Insulation Smart Roof TOP)

10,00 1030 135 0,038 0,1

8 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,18 960 1600 0,260 162,0

9 ekstrudirani polistiren u pločama XPS 5,00 1450 40 0,033 7,5

Ukupno: 66,90 841,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,10 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 10,06 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,10 + 0,00 = 0,10 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,25 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.105 8,4 0,347

2 veljača 1.154 1.154 9,1 0,301

3 ožujak 1.248 1.248 10,2 0,159

4 travanj 1.487 1.487 12,9 -

5 svibanj 1.853 1.853 16,3 -

6 lipanj 2.058 2.058 18,0 -

7 srpanj 2.058 2.058 18,0 -

8 kolovoz 2.058 2.058 18,0 -

9 rujan 1.819 1.819 16,0 -

10 listopad 1.451 1.451 12,5 0,003

11 studeni 1.229 1.229 10,0 0,195

12 prosinac 1.112 1.112 8,5 0,341

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,347 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,990 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 22

Proračun građevnog dijela zgrade

K2 Ravni neprohodni krov Građevni dio: Ravni i kosi krov iznad grijanog prostora

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 16,00 1000 2500 2,600 20,8

3 2.12 - beton s laganim agregatom (1200) 4,00 1000 1200 0,620 4,0

4 parna brana - bitumenska traka 4 mm s uloškom Al folije d= 0,2 mm 0,02 940 2700 203,000 160,0

5 ekstrudirani polistiren u pločama XPS 30,00 1450 40 0,033 45,0

6 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

7 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,15 960 1600 0,260 135,0

8 geotekstili (na bazi propilena) (*sloj ne ulazi u proračun) 0,02 1800 1200 0,250 0,0

9 oblutci - zaštitni sloj oblutaka 16-32 (*sloj ne ulazi u proračun) 7,00 840 1700 0,810 0,0

Ukupno: 57,71 365,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,10 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 9,37 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,11 + 0,00 = 0,11 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,25 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,989 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 23

Proračun građevnog dijela zgrade

K2a Ravni neprohodni krov, smještaj strojarskih uređaja – podnožja uređaja i opreme Građevni dio: Ravni i kosi krov iznad grijanog prostora

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 16,00 1000 2500 2,600 20,8

3 2.12 - beton s laganim agregatom (1200) 4,00 1000 1200 0,620 4,0

4 parna brana - bitumenska traka 4 mm s uloškom Al folije d= 0,2 mm 0,02 940 2700 203,000 160,0

5 ekstrudirani polistiren u pločama XPS 30,00 1450 40 0,033 45,0

6 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

7 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,15 960 1600 0,260 135,0

8 geotekstili (na bazi propilena) (*sloj ne ulazi u proračun) 0,02 1800 1200 0,250 0,0

9 Ethafoam 222-E - folija od ekstrudiranog polietilena (Dow Chemical) (*sloj ne ulazi u proračun)

1,00 1450 25 0,030 0,0

10 2.01 - armirani beton (2500) (*sloj ne ulazi u proračun) 12,00 1000 2500 2,600 0,0

Ukupno: 63,71 365,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,10 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 9,37 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,11 + 0,00 = 0,11 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,25 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Građevni dio ZADOVOLJAVA zahtjev za dinamičku toplinsku karakteristiku!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,989 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 24

Proračun građevnog dijela zgrade

M2 Međukatna konstrukcija grijanih prostora iznad otvorenog– pod dvorane za ergo-nomiju Građevni dio: Stropovi iznad vanjskog zraka

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 PVC homogen 0,40 960 1400 0,230 40,0

2 Šperploče lake 1,80 2090 550 0,140 1,1

3 4.05 - drvo - meko - crnogorica 3,50 2000 550 0,150 2,5

4 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

5 Cementni estrih 4,00 1050 2200 1,400 1,2

6 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

7 STIROPOR EPS 150 (prema HRN EN 13163) 1,00 1260 25 0,036 0,7

8 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

9 2.01 - armirani beton (2500) 22,00 1000 2500 2,600 28,6

10 mineralna vuna (MW) ploče za ventilirana pročelja s l=0,035 (KI ploče sa vo-alom FPL 035 GVB)

16,00 1030 50 0,035 0,2

11 dobro ventilirani zračni sloj (*sloj ne ulazi u proračun) 4,00 1008 1 0,025 0,0

Ukupno: 54,74 115,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,04 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 6,12 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,16 + 0,00 = 0,16 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,25 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,972 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 25

Proračun građevnog dijela zgrade

UZ2 Nosivi unutarnji armiranobetonski zid grijanog prostora prema negrijanom pros-toru Građevni dio: Zidovi prema negrijanim prostorijama i negrijanom stubištu temperature više od 0°C

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 30,00 1000 2500 2,600 39,0

3 mineralna vuna (MW) fasadne ploče s l=0,035 (Knauf Insulation FKD S Thermal)

10,00 1030 115 0,035 0,1

4 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom 0,30 1000 1800 0,700 0,6

5 Silikatna žbuka 1,5 0,20 1050 1850 0,870 0,1

Ukupno: 41,00 40,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,13 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,24 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,31 + 0,00 = 0,31 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,959 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 26

Proračun građevnog dijela zgrade

UZ3 Laka pregradna stijena između grijanog i negrijanog prostora d=15,0cm (prema spremištu u prizemlju), laka pregradna stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm Građevni dio: Zidovi prema negrijanim prostorijama i negrijanom stubištu temperature više od 0°C

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Knauf Diamant ploče 2,50 900 1024 0,250 0,2

2 parna brana - Knauf Insulation LDS 100 AL-PE aluminizirana parna brana 0,02 940 1800 203,000 70,0

3 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W) 10,00 1030 15 0,037 0,1

4 Knauf Diamant ploče 2,50 900 1024 0,250 0,2

Ukupno: 15,02 71,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,13 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,16 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,32 + 0,00 = 0,32 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.105 8,4 0,347

2 veljača 1.154 1.154 9,1 0,301

3 ožujak 1.248 1.248 10,2 0,159

4 travanj 1.487 1.487 12,9 -

5 svibanj 1.853 1.853 16,3 -

6 lipanj 2.058 2.058 18,0 -

7 srpanj 2.058 2.058 18,0 -

8 kolovoz 2.058 2.058 18,0 -

9 rujan 1.819 1.819 16,0 -

10 listopad 1.451 1.451 12,5 0,003

11 studeni 1.229 1.229 10,0 0,195

12 prosinac 1.112 1.112 8,5 0,341

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,347 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,958 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 27

Proračun građevnog dijela zgrade

M6 Međukatna konstrukcija grijanog prostora na katu iznad negrijane prostorije pri-zemlja Građevni dio: Stropovi iznad negrijanih prostorija i negrijanog stubišta temperature više od 0°C

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Cementni estrih 4,00 1050 2200 1,400 1,2

2 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

3 STIROPOR EPS 150 (prema HRN EN 13163) 5,00 1260 25 0,036 3,5

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

5 2.01 - armirani beton (2500) 22,00 1000 2500 2,600 28,6

6 mineralna vuna (MW) fasadne ploče s l=0,035 (Knauf Insulation FKD S Thermal)

5,00 1030 115 0,035 0,1

7 polimercementno ljepilo armirano alkalnootpornom staklenom mrežicom 0,30 1000 1800 0,700 0,6

8 Silikatna žbuka 1,5 0,20 1050 1850 0,870 0,1

Ukupno: 38,52 55,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,17 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,85 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,26 + 0,00 = 0,26 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Kondenzacija na površini:

mjesec tlak pare u prost. pi

(Pa) tlak zasić. pare psat

(Pa) površ. temp. Θsi,min

(°C) faktor temp.

frsi

1 siječanj 1.105 1.382 11,8 0,536

2 veljača 1.154 1.443 12,4 0,515

3 ožujak 1.248 1.560 13,6 0,451

4 travanj 1.487 1.858 16,3 0,394

5 svibanj 1.853 2.316 19,9 0,351

6 lipanj 2.058 2.572 21,6 0,140

7 srpanj 2.058 2.572 21,6 -

8 kolovoz 2.058 2.572 21,6 -

9 rujan 1.819 2.274 19,6 0,356

10 listopad 1.451 1.814 16,0 0,397

11 studeni 1.229 1.537 13,4 0,468

12 prosinac 1.112 1.390 11,9 0,533

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje plijesni (<0.8).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,536 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (RT - Rsi)/RT = 0,954 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Unutrašnja kondenzacija: Raspodjela tlakova vodene pare u građevnom dijelu za mjesec si-ječanj.

-

-

-

Građevni dio ZADOVOLJAVA zahtjev za unutrašnju kondenzaciju!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 28

Proračun građevnog dijela zgrade

PZ1 Armiranobetonski zid grijanih prostorija prema tlu Građevni dio: Zidovi prema tlu

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 30,00 1000 2500 2,600 39,0

3 5.10 - polimerna hidroizolacijska traka na bazi FPO/TPO 0,15 960 1600 0,260 135,0

4 geotekstil (na bazi propilena) 0,02 1800 1200 0,250 0,0

5 ekstrudirani polistiren u pločama XPS 12,00 1450 40 0,033 18,0

6 PEHD folija - drenažna traka s bradavicama 1cm/1mm (*sloj ne ulazi u pro-račun)

0,10 1800 980 0,500 0,0

Ukupno: 42,77 192,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,00 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,89 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,26 + 0,00 = 0,26 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

P1 Pod na tlu grijanog prostora u prizemlju Građevni dio: Podovi na tlu

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Cementni estrih 4,00 1050 2200 1,400 1,2

2 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

3 STIROPOR EPS 150 (prema HRN EN 13163) 10,00 1260 25 0,036 7,0

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

5 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

6 5.01 - bitumenska traka s uloškom staklenog voala 1,00 1000 1100 0,230 500,0

7 2.01 - armirani beton (2500) (*sloj ne ulazi u proračun) 20,00 1000 2500 2,600 0,0

Ukupno: 37,04 529,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,00 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,59 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,28 + 0,00 = 0,28 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 29

Proračun građevnog dijela zgrade

P2 Pod na tlu u sanitarijama grijanog prostora u prizemlju Građevni dio: Podovi na tlu

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.03 - keramičke pločice 0,80 840 2300 1,300 1,6

2 Građevinsko ljepilo 0,20 1050 1600 1,000 0,1

3 polimercementni hidroizolacijski premaz 0,20 1000 1100 0,700 0,4

4 Cementni estrih 4,00 1050 2200 1,400 1,2

5 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

6 STIROPOR EPS 150 (prema HRN EN 13163) 10,00 1260 25 0,036 7,0

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

8 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

9 5.01 - bitumenska traka s uloškom staklenog voala 1,00 1000 1100 0,230 500,0

10 2.01 - armirani beton (2500) (*sloj ne ulazi u proračun) 20,00 1000 2500 2,600 0,0

Ukupno: 38,24 532,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,00 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,60 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,28 + 0,00 = 0,28 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

P3 Pod na tlu u sanitarijama grijanog prostora u prizemlju + podno grijanje Građevni dio: Podovi na tlu

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.03 - keramičke pločice 0,80 840 2300 1,300 1,6

2 Građevinsko ljepilo 0,20 1050 1600 1,000 0,1

3 polimercementni hidroizolacijski premaz 0,20 1000 1100 0,700 0,4

4 Cementni estrih 6,50 1050 2200 1,400 2,0

5 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

6 STIROPOR EPS 150 (prema HRN EN 13163) 10,00 1260 25 0,036 7,0

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

8 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

9 5.01 - bitumenska traka s uloškom staklenog voala 1,00 1000 1100 0,230 500,0

10 2.01 - armirani beton (2500) (*sloj ne ulazi u proračun) 20,00 1000 2500 2,600 0,0

Ukupno: 40,74 532,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,00 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,62 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,28 + 0,00 = 0,28 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 30

Proračun građevnog dijela zgrade

P5 Pod na tlu grijanog prostora na katu Građevni dio: Podovi na tlu

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Cementni estrih 4,00 1050 2200 1,400 1,2

2 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

3 STIROPOR EPS 150 (prema HRN EN 13163) 5,00 1260 25 0,036 3,5

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

5 2.01 - armirani beton (2500) 22,00 1000 2500 2,600 28,6

6 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

7 ekstrudirani polistiren u pločama XPS 5,00 1450 40 0,033 7,5

8 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

9 5.05 - polimerna hidroizolacijska traka na bazi PVC-P 0,15 1000 1200 0,140 150,0

10 geotekstili (na bazi propilena) (*sloj ne ulazi u proračun) 0,02 1800 1200 0,250 0,0

11 donja betonska podloga, armirana i zaglađena (*sloj ne ulazi u proračun) 10,00 1000 2400 2,500 0,0

Ukupno: 48,23 232,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,00 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,77 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,27 + 0,00 = 0,27 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

P6 Pod na tlu u sanitarijama grijanog prostora na katu + podno grijanje Građevni dio: Podovi na tlu

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.03 - keramičke pločice 0,80 840 2300 1,300 1,6

2 Građevinsko ljepilo 0,20 1050 1600 1,000 0,1

3 polimercementni hidroizolacijski premaz 0,20 1000 1100 0,700 0,4

4 Cementni estrih 6,50 1050 2200 1,400 2,0

5 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

6 STIROPOR EPS 150 (prema HRN EN 13163) 5,00 1260 25 0,036 3,5

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

8 2.01 - armirani beton (2500) 22,00 1000 2500 2,600 28,6

9 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

10 ekstrudirani polistiren u pločama XPS 5,00 1450 40 0,033 7,5

11 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

12 5.05 - polimerna hidroizolacijska traka na bazi PVC-P 0,15 1000 1200 0,140 150,0

13 geotekstili (na bazi propilena) (*sloj ne ulazi u proračun) 0,02 1800 1200 0,250 0,0

14 donja betonska podloga, armirana i zaglađena (*sloj ne ulazi u proračun) 10,00 1000 2400 2,500 0,0

Ukupno: 51,93 235,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,00 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,80 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,26 + 0,00 = 0,26 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 0,40 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 31

Proračun građevnog dijela zgrade

P4 Pod na tlu negrijanog prostora u prizemlju Građevni dio: Neprozirni građevni dijelovi u negrijanom prostoru

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.03 - keramičke pločice 0,80 840 2300 1,300 1,6

2 Građevinsko ljepilo 0,20 1050 1600 1,000 0,1

3 Cementni estrih 4,00 1050 2200 1,400 1,2

4 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

5 STIROPOR EPS 150 (prema HRN EN 13163) 6,00 1260 25 0,036 4,2

6 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

7 geotekstili (na bazi propilena) 0,02 1800 1200 0,250 0,0

8 5.01 - bitumenska traka s uloškom staklenog voala 1,00 1000 1100 0,230 500,0

9 2.01 - armirani beton (2500) (*sloj ne ulazi u proračun) 20,00 1000 2500 2,600 0,0

Ukupno: 34,04 528,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,00 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 2,49 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,40 + 0,00 = 0,40 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 100,00 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

M1 Međukatna konstrukcija između grijanih prostora – pod dvorane za ergonomiju Građevni dio: Ostali građevni dijelovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 PVC homogen 0,40 960 1400 0,230 40,0

2 Šperploče lake 1,80 2090 550 0,140 1,1

3 4.05 - drvo - meko - crnogorica 3,50 2000 550 0,150 2,5

4 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

5 Cementni estrih 4,00 1050 2200 1,400 1,2

6 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

7 STIROPOR EPS 150 (prema HRN EN 13163) 1,00 1260 25 0,036 0,7

8 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

9 2.01 - armirani beton (2500) 22,00 1000 2500 2,600 28,6

10 Neprovjetravani sloj zraka - toplinski tok vodoravan d=50mm 5,00 1005 1 0,278 0,1

11 4.01 - gipskartonske ploče 1,25 900 900 0,250 0,1

Ukupno: 40,99 115,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,10 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 1,84 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,54 + 0,00 = 0,54 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 100,00 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 32

Proračun građevnog dijela zgrade

M3 Međukatna konstrukcija između grijanih prostora (hodnik) Građevni dio: Ostali građevni dijelovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Cementni estrih 4,00 1050 2200 1,400 1,2

2 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

3 STIROPOR EPS 150 (prema HRN EN 13163) 5,00 1260 25 0,036 3,5

4 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

5 2.01 - armirani beton (2500) 22,00 1000 2500 2,600 28,6

6 Neprovjetravani sloj zraka - toplinski tok vodoravan d=50mm 5,00 1005 1 0,278 0,1

7 4.01 - gipskartonske ploče 1,25 900 900 0,250 0,1

Ukupno: 39,27 55,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,10 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 2,57 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,39 + 0,00 = 0,39 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 100,00 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

M4 Međukatna konstrukcija u sanitarijama između grijanih prostora Građevni dio: Ostali građevni dijelovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.03 - keramičke pločice 0,80 840 2300 1,300 1,6

2 Građevinsko ljepilo 0,20 1050 1600 1,000 0,1

3 polimercementni hidroizolacijski premaz 0,20 1000 1100 0,700 0,4

4 Cementni estrih 4,00 1050 2200 1,400 1,2

5 Polietilen / politen, mala gustoća 0,02 2200 920 0,330 20,0

6 STIROPOR EPS 150 (prema HRN EN 13163) 5,00 1260 25 0,036 3,5

7 elastificirani ekspandirani polistiren (EPS) za plivajuće podne obloge 2,00 1450 15 0,035 1,2

8 2.01 - armirani beton (2500) 22,00 1000 2500 2,600 28,6

9 Neprovjetravani sloj zraka - toplinski tok vodoravan d=50mm 5,00 1005 1 0,278 0,1

10 4.01 - gipskartonske ploče 1,25 900 900 0,250 0,1

Ukupno: 40,47 57,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,17 m²K/W, Rse = 0,10 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 2,59 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,39 + 0,00 = 0,39 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 100,00 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 33

Proračun građevnog dijela zgrade

UZ1 Nosivi unutarnji armiranobetonski zid Građevni dio: Ostali građevni dijelovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 cementna glet masa 0,50 1050 1500 1,000 0,1

2 2.01 - armirani beton (2500) 30,00 1000 2500 2,600 39,0

3 cementna glet masa 0,50 1050 1500 1,000 0,1

Ukupno: 31,00 39,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,13 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 0,39 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 2,59 + 0,00 = 2,59 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 100,00 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

UZ4 Laka pregradna stijena s poboljšanim zvučnim karakteristikama d=15,0cm (iz-među dvije višenamjenske prostorije za edukaciju i prema drugom prostorijama, laki zid dvorane prema drugim prostorijama, zidovi kabineta) Građevni dio: Ostali građevni dijelovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 Knauf Diamant ploče 2,50 900 1024 0,250 0,2

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W) 10,00 1030 15 0,037 0,1

3 Knauf Diamant ploče 2,50 900 1024 0,250 0,2

Ukupno: 15,00 1,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,13 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 3,16 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,32 + 0,00 = 0,32 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 100,00 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 34

Proračun građevnog dijela zgrade

UZ5 Unutarnji laki pregradni zid (sanitarije i sl.), laka pregradna stijena od gipskar-tonskih ploča na metalnoj potkonstrukciji - debljine 10,0 cm Građevni dio: Ostali građevni dijelovi

sloj materijal debljina

d (cm) spec. topl. cp (J/kgK)

gustoća ρ (kg/m³)

topl.prov. λ (W/mK)

dif.otpor. Sd (m)

1 4.01 - gipskartonske ploče 2,50 900 900 0,250 0,2

2 mineralna vuna (MW) staklena l= 0,037 (Knauf Insulation filc TI 140 W) 5,00 1030 15 0,037 0,1

3 4.01 - gipskartonske ploče 2,50 900 900 0,250 0,2

Ukupno: 10,00 0,0

Koeficijent prolaska topline: Plošni otpor prijelaza topline, Rsi = 0,13 m²K/W, Rse = 0,13 m²K/W Toplinski otpor homogenih slojeva, RT= Rsi + Σdi/λi + Rse = 1,81 m²K/W Koeficijent prolaska topline, U = 1/(RT + Ru) + ΔU = 0,55 + 0,00 = 0,55 W/m²K Dozvoljeni koeficijent prolaska topline za građevni dio, Umax = 100,00 W/m²K

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

V1 Vanjska vrata grijanih prostora - neprozirno vratno krilo Građevni dio: Vanjska vrata, s neprozirnim vratnim krilom

Koeficijent prolaska topline: Koeficijent prolaska topline, U ( W/m²K) 2,00

Dozvoljeni koef. prolaska topline, Umax (W/m²K) 2,00

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun građevnog dijela zgrade

V2 Vrata grijanog prostora prema negrijanom prostoru (spremište u prizemlju) Građevni dio: Vrata prema negrijanom stubištu, s neprozirnim vratnim krilom

Koeficijent prolaska topline: Koeficijent prolaska topline, U ( W/m²K) 2,00

Dozvoljeni koef. prolaska topline, Umax (W/m²K) 2,00

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 35

Proračun građevnog dijela zgrade

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33 Građevni dio: Prozori Koeficijent prolaska topline: Koef. prolaska topline okvira, Uokv (W/m²K) (uključivo linijski toplinski most između okvira i stakla)

2,40

Koeficijent prolaska topline stakla, Ug (W/m²K) 1,10

Udio ostakljenja u ploštini otvora, (1-Ff) (-) 0,70

Ukupni koeficijent prolaska topline, Uw (W/m²K) 1,49 Dozvoljeni koef. prolaska topline, Uw,max (W/m²K) 1,60

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Stupanj prop. ukupne en. kroz ostaklj., g=gokomito*0.9 (-)

0,30

Faktor zasjenjenja, Fsh (-) 1,00

Orijentacija prozora: S - od obzora: Kuthor:0° - od nadstrešnice: Kutov:0° - od bočnih zaslona: Kutfin:0°

Faktor smanjenja zbog zašt. od sunca, Fc,H (-) - zimi 1,00

Faktor smanjenja zbog zašt. od sunca, Fc,C (-) - ljeti 1,00

Kondenzacija na površini: Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje kondenzacije (<1.0).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,000 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (Rt - Rsi)/RT = 0,838 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Proračun građevnog dijela zgrade

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo / mutno neprozirno staklo s g=60 Građevni dio: Prozori Koeficijent prolaska topline: Koef. prolaska topline okvira, Uokv (W/m²K) (uključivo linijski toplinski most između okvira i stakla)

2,40

Koeficijent prolaska topline stakla, Ug (W/m²K) 1,10

Udio ostakljenja u ploštini otvora, (1-Ff) (-) 0,70

Ukupni koeficijent prolaska topline, Uw (W/m²K) 1,49 Dozvoljeni koef. prolaska topline, Uw,max (W/m²K) 1,60

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Stupanj prop. ukupne en. kroz ostaklj., g=gokomito*0.9 (-)

0,54

Faktor zasjenjenja, Fsh (-) 1,00

Orijentacija prozora: S - od obzora: Kuthor:0° - od nadstrešnice: Kutov:0° - od bočnih zaslona: Kutfin:0°

Faktor smanjenja zbog zašt. od sunca, Fc,H (-) - zimi 1,00

Faktor smanjenja zbog zašt. od sunca, Fc,C (-) - ljeti 1,00

Kondenzacija na površini:

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 36

Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje kondenzacije (<1.0).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,000 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (Rt - Rsi)/RT = 0,838 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Proračun građevnog dijela zgrade

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo + unutarnje žaluzine Građevni dio: Prozori Koeficijent prolaska topline: Koef. prolaska topline okvira, Uokv (W/m²K) (uključivo linijski toplinski most između okvira i stakla)

2,40

Koeficijent prolaska topline stakla, Ug (W/m²K) 1,10

Udio ostakljenja u ploštini otvora, (1-Ff) (-) 0,70

Ukupni koeficijent prolaska topline, Uw (W/m²K) 1,49 Dozvoljeni koef. prolaska topline, Uw,max (W/m²K) 1,60

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Stupanj prop. ukupne en. kroz ostaklj., g=gokomito*0.9 (-)

0,54

Faktor zasjenjenja, Fsh (-) 1,00

Orijentacija prozora: S - od obzora: Kuthor:0° - od nadstrešnice: Kutov:0° - od bočnih zaslona: Kutfin:0°

Faktor smanjenja zbog zašt. od sunca, Fc,H (-) - zimi 1,00

Faktor smanjenja zbog zašt. od sunca, Fc,C (-) - ljeti 0,75

Kondenzacija na površini: Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje kondenzacije (<1.0).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,000 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (Rt - Rsi)/RT = 0,838 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Proračun građevnog dijela zgrade

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo + unutarnje žaluzine + streha Građevni dio: Prozori Koeficijent prolaska topline: Koef. prolaska topline okvira, Uokv (W/m²K) (uključivo linijski toplinski most između okvira i stakla)

2,40

Koeficijent prolaska topline stakla, Ug (W/m²K) 1,10

Udio ostakljenja u ploštini otvora, (1-Ff) (-) 0,70

Ukupni koeficijent prolaska topline, Uw (W/m²K) 1,49 Dozvoljeni koef. prolaska topline, Uw,max (W/m²K) 1,60

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 37

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Stupanj prop. ukupne en. kroz ostaklj., g=gokomito*0.9 (-)

0,54

Faktor zasjenjenja, Fsh (-) 1,00

Orijentacija prozora: S - od obzora: Kuthor:0° - od nadstrešnice: Kutov:0° - od bočnih zaslona: Kutfin:0°

Faktor smanjenja zbog zašt. od sunca, Fc,H (-) - zimi 1,00

Faktor smanjenja zbog zašt. od sunca, Fc,C (-) - ljeti 0,38

Kondenzacija na površini: Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje kondenzacije (<1.0).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,000 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (Rt - Rsi)/RT = 0,838 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Proračun građevnog dijela zgrade

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni dijelovi – dvoslojno staklo + vanjski brisoleji Građevni dio: Prozori Koeficijent prolaska topline: Koef. prolaska topline okvira, Uokv (W/m²K) (uključivo linijski toplinski most između okvira i stakla)

2,40

Koeficijent prolaska topline stakla, Ug (W/m²K) 1,10

Udio ostakljenja u ploštini otvora, (1-Ff) (-) 0,70

Ukupni koeficijent prolaska topline, Uw (W/m²K) 1,49 Dozvoljeni koef. prolaska topline, Uw,max (W/m²K) 1,60

Građevni dio ZADOVOLJAVA zahtjev za koeficijent prolaska topline!

Stupanj prop. ukupne en. kroz ostaklj., g=gokomito*0.9 (-)

0,54

Faktor zasjenjenja, Fsh (-) 1,00

Orijentacija prozora: S - od obzora: Kuthor:0° - od nadstrešnice: Kutov:0° - od bočnih zaslona: Kutfin:0°

Faktor smanjenja zbog zašt. od sunca, Fc,H (-) - zimi 1,00

Faktor smanjenja zbog zašt. od sunca, Fc,C (-) - ljeti 0,30

Kondenzacija na površini: Nepoznati unutarnji uvjeti - mali intenzitet korištenja.

Kontinentalna i tropska klima.

Unutarnja projektna temperatura, θi = 20,0 (°C), Sprječavanje kondenzacije (<1.0).

Faktor temperature na unutarnjoj površini za kritičan mjesec, frsi,max = 0,000 (-) Projektni faktor temperature na unutarnjoj površini, frsi = (Rt - Rsi)/RT = 0,853 (-)

Građevni dio ZADOVOLJAVA zahtjev za kondenzaciju na površini!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 38

PODACI O ZONAMA

OSNOVNA ZONA - Toplinska zona zgrade s najvećom Ak ZONA PRETEŽITE NAMJENE ZGRADE

Obujam grijanog dijela, Ve (m³): 6.074,51

Neto obujam, V (m³): 4.010,92

Ploština korisne površine, Ak (m²): 903,67

Bruto podna površina, Af (m²): 1.053,97

Oplošje grijanog dijela, A (m²): 2.431,22

Faktor oblika, fo (m-1): 0,40

Proj. unutar. temp. grijanja, Θint,set,H (°C): 20

Proj. unutar. temp. hlađenja, Θint,set,C (°C):

22

Vremenska konstanta, τ (h): 34,70

Toplinski kapacitet, Cm (MJ/K): 173,91

Unutarnji dobitak po jed. površ. Ak (W/m²): 6

Korištenje zone:

Grijanje sat/dan, dan/tjedan 14 5

Faktor prekidanog grijanja, fH,hr (-) 0,42

Hlađenje dan/tjedan 14 5

Faktor prekidanog hlađenja, fC,day (-)

0,42

Dani nekorištenja zone

mjesec I II III IV V VI VII VIII IX X XI XII

dani nekorištenja 0 0 0 0 0 0 0 0 0 0 0 0

Koeficijent transmisijskih toplinskih gubitaka, Htr (W/K)

Direktni toplinski gubici kroz neprozirne plohe vanjskih građevnih dijelova, ΣAiUi (W/K)

oznaka naziv nagib/

orijentacija koef.topl.proh.

U (W/m²K) površina

A (m²) topl.gubitak

AU (W/K)

Z1 Z1 Vanjski ventilirani zid u prizemlju 90/S 0,23 42,0 11,8

Z1 Z1 Vanjski ventilirani zid u prizemlju 90/W 0,23 7,0 2,0

Z2 Z2 Vanjski ventilirani zid na katu - sokl 90/N 0,22 146,9 39,7

Z2 Z2 Vanjski ventilirani zid na katu - sokl 90/E 0,22 149,2 40,3

Z2 Z2 Vanjski ventilirani zid na katu - sokl 90/S 0,22 140,0 37,8

Z2 Z2 Vanjski ventilirani zid na katu - sokl 90/W 0,22 76,5 20,7

Z3 Z3 Vanjski zid s ETICS fasadom – zapadno pročelje dvo-rane

90/W 0,16 86,0 18,1

V1 V1 Vanjska vrata grijanih prostora - neprozirno vratno krilo 90/W 2,00 2,1 4,2

M2 M2 Međukatna konstrukcija grijanih prostora iznad otvore-nog– pod dvorane za ergonomiju

0/Hor 0,16 109,3 23,0

K1 K1 Ravni zeleni laki krov dvorane za ergonomiju 0/Hor 0,10 474,5 71,2

K2/K2a K2 Ravni neprohodni krov 0/Hor 0,11 174,5 27,9

Z1 Z1 Vanjski ventilirani zid u prizemlju 90/N 0,23 37,0 10,3

Z1 Z1 Vanjski ventilirani zid u prizemlju 90/E 0,23 35,0 9,8

Ukupno: 1479,9 316,6

* toplinski gubici su računati sa povećanim koeficijentom prolaska topline za ∆UTM = 0,05 W/(m²·K).

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 39

Direktni toplinski gubici kroz prozirne plohe vanjskih građevnih dijelova, ΣAiUi (W/K)

oznaka naziv nagib/

orijentacija koef.topl.proh.

U (W/m²K) površina

A (m²) topl.gubitak

AU (W/K)

PR1 - dvorana mutno staklo

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo / mutno neprozirno staklo s g=60

90/S 1,49 7,5 11,2

PR1 - brisoleji PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo + vanjski brisoleji

90/E 1,49 75,5 112,5

PR1 - brisoleji PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo + vanjski brisoleji

90/W 1,49 49,1 73,2

PR1 - unutarnja zaštita PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo + unutarnje žaluzine

90/S 1,49 1,8 2,7

PR1 - ostakljena vrata PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33

90/N 1,49 19,8 29,6

PR1 - ostakljena vrata PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33

90/S 1,49 12,8 19,1

PR1 - u sjeni s un.zašti-tom

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo + unutarnje žaluzine + streha

90/N 1,49 15,2 22,6

PR1 - u sjeni s un.zašti-tom

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo + unutarnje žaluzine + streha

90/E 1,49 53,9 80,3

PR1 - u sjeni s un.zašti-tom

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo + unutarnje žaluzine + streha

90/S 1,49 9,0 13,4

PR1 - staklena stijena stubišta

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33

90/W 1,49 7,3 10,8

PR1 - dvorana mutno staklo

PR1 Prozori, ostakljena vrata, staklene stijene, ostakljeni di-jelovi – dvoslojno staklo / mutno neprozirno staklo s g=60

90/N 1,49 7,5 11,2

Ukupno: 259,3 386,4

Koeficijent toplinskog gubitka kroz tlo, Hg (W/K)

naziv visina zid. u tlu

z (m) ploština poda,

A (m²)

izloženi op-seg,

P (m)

period. koef., Hpe (W/K) topl. gubitak, Hg (W/K)

Gubitak kroz tlo - prizemlje 1,4 370,2 83,2 21,7 127,3

Gubitak kroz tlo - kat 99,6 58,5 10,0 54,7

Ukupno: 469,7 141,7 31,8 182,0

Koeficijent toplinskih gubitaka kroz negrijane prostorije, Hu (W/K)

naziv neto obujam, V

(m3) br. izmj.

zraka, n (1/h)

korekcijski faktor, b (-)

topl. gubitak, Hu (W/K)

Negrijana prostorija 47,6 1,0 0,65 13,0

Ukupno: 47,6 13,0

Koeficijent toplinskog gubitka zbog provjetravanja, Hve (W/K)

naziv obujam zraka, V

(m³) br. izmj. zraka,

n (1/h) topl. gubitak

Hve (W/K) Faktor prekida ventilacije, fV,hr (-

) Zrakopropusnost zgrade, n50 (h-

1) Koeficijent zaštićenosti

od vjetra, e (-) Proj. protok zraka zbog meh. provj.,

Vf (m3/s) Iskor. sust. za povrat topline., ηv

(-) Ventilacijski gubitak 936,8 0,5 156,1

Ventilacijski gubitak - dvorana (rekuperacija) 2520,0 195,9

0,36 1,67 0,04 1,10 0,89

Ventilacijski gubitak - prizemlje (rekuperacija) 554,1 142,0

0,36 3,20 0,04 2,20 0,89

Ukupno: 4010,9 494,1

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 40

Koeficijent transmisijskih toplinskih gubitaka:

- direktnih, HD (W/K) 703,0 - kroz tlo, Hg (W/K) 182,0 - kroz negrijane prostorije, Hu (W/K) 13,0 - kroz negrijane prostorije - staklenike, Hus (W/K) 0,0 - kroz susjedne prostorije, HA (W/K) 0,0

Koef. transmisijskih topl. gubitaka, Htr,adj (W/K) 898,0

Koef.ventilacijskih topl. gubitaka, Hve,adj (W/K) 494,1

Koeficijent ukupnih toplinskih gubitaka, H (W/K) 1.392,0

Toplinski dobici od sunca, Qsol (kWh)

naziv oznaka nagib/

orijentacija površina,

A (m²) 1-Ff Fc Fsh g

Aef=A*(1-Ff)* Fsh*Fc*g*Fw (m²)

solarni dobici za mjesec, Qsol (kWh) I II III IV V VI VII VIII IX X XI XII

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo / mutno neprozirno staklo s g=60

PR1 - dvorana mutno staklo

S/90 7,50 0,70 1,00 1,00 0,60 2,8

114 149 235 235 243 233 255 263 280 240 132 83

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo + vanjski brisoleji

PR1 - brisoleji E/90 75,50 0,70 1,00 1,00 0,60 28,5

626 935 1847 2442 3060 3195 3456 2989 2386 1522 729 460

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo + vanjski brisoleji

PR1 - brisoleji W/90 49,10 0,70 1,00 1,00 0,60 18,6

407 608 1201 1588 1990 2078 2248 1944 1552 990 474 299

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo + unutarnje žaluzine

PR1 - unutarnja zaštita

S/90 1,80 0,70 1,00 1,00 0,60 0,7

27 36 56 57 58 56 61 63 67 58 32 20

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33

PR1 - ostakljena vrata

N/90 19,84 0,70 1,00 1,00 0,33 4,1

56 79 142 187 236 245 245 213 155 109 63 45

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33

PR1 - ostakljena vrata

S/90 12,83 0,70 1,00 1,00 0,33 2,7

107 140 221 222 229 219 240 247 264 226 124 79

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo + unutarnje žaluzine + streha

PR1 - u sjeni s un.zaštitom

N/90 15,17 0,70 1,00 1,00 0,60 5,7

78 110 198 260 328 341 341 296 215 151 88 62

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo + unutarnje žaluzine + streha

PR1 - u sjeni s un.zaštitom

E/90 53,86 0,70 1,00 1,00 0,60 20,4

447 667 1318 1742 2183 2279 2466 2132 1702 1086 520 328

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo + unutarnje žaluzine + streha

PR1 - u sjeni s un.zaštitom

S/90 8,96 0,70 1,00 1,00 0,60 3,4

136 178 280 281 291 278 305 314 335 287 157 100

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo / bez zaštite od sunca s g=0,33

PR1 - staklena stijena stubišta

W/90 7,26 0,70 1,00 1,00 0,33 1,5

33 49 98 129 162 169 183 158 126 80 39 24

PR1 Prozori, ostakljena vrata, staklene sti-jene, ostakljeni dijelovi – dvoslojno staklo / mutno neprozirno staklo s g=60

PR1 - dvorana mutno staklo

N/90 7,50 0,70 1,00 1,00 0,60 2,8

39 54 98 128 162 169 169 146 106 75 43 31

Ukupni mjes. dob. od sunca, Qsol (kWh) 2070 3005 5694 7271 8942 9262 9969 8765 7188 4824 2401 1531

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 41

Unutarnji dobici topline računati sa zadanom vrijednošću, Qint (kWh)

Korisna površina zgrade, Ak (m2) 903,7 Unutarnji dobitak po 1m2 korisne površine (W/m2) 6,0

Unutarnji topl. dob. računan sa zadatom vrijed., (W) 5.422,0

Potrebna energija za grijanje, QH,nd (kWh)

Vremenska konstanta: τ = Cm/H = 34,70 (h)

Omjer između dobitaka i gubitaka topline: γH = QH,gn/QH,ht = (QH,int + QH,sol)/(QH,tr + QH,ve) (-) Stupanj iskorištenja dobitaka: ηH,gn = (1- γHa)/( 1- γHa+1) za γH>0 i γH<>1 ηH,gn = a/(a+1) za γH=1 ηH,gn = 1/γH za γH<0 Gdje je: aH = aH,o + τ/τH,o = 1 + 34,70/15 = 3,31 Faktor smanjenja zbog prekidnog grijanja: αH,red = 1 - bH,red(τH,o/τ)γH(1-fH,hr) (-), gdje je bH,red=3

Transmisijski gubici za mjesec:, Qtr = (HD + Hu + Hus) ( Θi - Θe) t + Qg + QA (kWh)

- kroz tlo, Qg = Hg (Θi - Θˉe) t + Hpe Θ^e cos(2π(m-τ-β)/12) t - kroz susjedne zone (y), QA = HA (Θi - Θy) t

gdje je: t - trajanje mjesečnog razdoblja grijanja (h), Θˉe - prosječna godišnja vanjska temperatura (°C), Θ^e - mjesečno odstupanje od prosječne godišnje vanjske temperature (°C), m - broj mjeseca, τ - mjesec sa minimalnom temperaturom (predpostavlja se 1), β - vremenski pomak (uzimima se 1 ili 2 ovisno o tipu poda), Θy - unutarnja temperatura susjedne zone (°C), Hpe - vanjski periodički koeficijent prijenosa topline (W/K)

mjesec vanj.

temp. Θe

(°C)

transmisijski

gubici

Qtr

(kWh)

ventilacijski gu-

bici

Qve

(kWh)

ukup. gubici

Qls=

Qtr+Qve

(kWh)

unutrašnji do-

bici

Qint

(kWh)

solarni dobici

Qsol

(kWh)

ukup. dobici

Qgn

=Qint+Qsol

(kWh)

omjer

dob/gub

γ=Qgn/Ql

s

(-)

iskor. do-

bit.

ηH,gn

(-)

faktor u-

manj.

αH,red

(-)

potrebna topl. za

grijanje

Qnd,H

(kWh) 1 siječanj 2,3 10.220 6.506 16.726 4.034 2.070 6.104 0,36 0,977 0,72 7.791

2 veljača 4,4 8.236 5.179 13.415 3.644 3.005 6.649 0,50 0,948 0,63 4.445

3 ožujak 8,4 7.095 4.264 11.359 4.034 5.694 9.728 0,86 0,824 0,42 1.394

4 travanj 13,0 4.583 2.490 7.073 3.904 7.271 11.175 1,58 0,574 0,42 276

5 svibanj 17,7 2.227 845 3.073 4.034 8.942 12.976 4,22 0,235 0,42 8

6 lipanj 21,0 358 -356 3 3.904 9.262 13.166 4743,94 0,000 0,42 0

7 srpanj 22,8 -698 -1.029 -1.727 4.034 9.969 14.003 -8,11 0,000 1,00 0

8 kolovoz 22,4 -508 -882 -1.390 4.034 8.765 12.799 -9,21 0,000 1,00 0

9 rujan 17,3 2.268 960 3.229 3.904 7.188 11.092 3,44 0,288 0,42 16

10 listopad 12,5 4.998 2.757 7.755 4.034 4.824 8.858 1,14 0,715 0,42 593

11 studeni 7,6 7.362 4.411 11.773 3.904 2.401 6.305 0,54 0,937 0,60 3.489

12 prosinac 2,6 10.153 6.396 16.549 4.034 1.531 5.565 0,34 0,982 0,75 8.265

Ukupno: 56.295 31.541 87.836 47.497 70.922 118.419 26.277

Potrebna energija za hlađenje, QC,nd (kWh)

Omjer između dobitaka i gubitaka topline: γC = QC,gn/QC,ht = (QC,int + QC,sol)/(QC,tr + QC,ve) (-) Stupanj iskorištenja gubitaka: ηC,ls = (1- γC-a)/( 1- γC-(a+1)) za γC>0 i za γC<>1 ηC,ls = a/(a+1) za γC=1 ηC,ls = 1 za γC<0 Gdje je: aC = aC,o + τ/τC,o = 1 + 34,70/15 = 3,31 Faktor smanjenja zbog prekidnog grijanja: αC,red = 1 - bC,red(τC,o/τ)γC(1-fC,day) (-), gdje je bC,red=3

mjesec vanj.

temp. Θe

(°C)

transmisijski

gubici

Qtr

(kWh)

ventilacijski gu-

bici

Qve

(kWh)

ukup. gubici

Qls=

Qtr+Qve

(kWh)

unutrašnji do-

bici

Qint

(kWh)

solarni dobici

Qsol

(kWh)

ukup. dobici

Qgn=

Qint+Qsol

(kWh)

omjer

dob/gub

γ=Qgn/Ql

s

(-)

iskor. gu-

bit.

ηC,ls

(-)

faktor u-

manj.

αC,red

(-)

potrebna en. za hla-

đenje

Qnd,C

(kWh) 1 siječanj 2,3 11.556 7.241 18.797 4.034 928 4.962 0,26 0,991 0,80 36

2 veljača 4,4 9.442 5.843 15.286 3.644 1.320 4.964 0,32 0,984 0,75 61

3 ožujak 8,4 8.431 4.999 13.430 4.034 2.423 6.457 0,48 0,952 0,64 196

4 travanj 13,0 5.876 3.201 9.077 3.904 3.007 6.911 0,76 0,860 0,42 410

5 svibanj 17,7 3.564 1.581 5.144 4.034 3.642 7.676 1,49 0,599 0,42 1.283

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 42

6 lipanj 21,0 1.652 356 2.007 3.904 3.745 7.649 3,81 0,260 0,42 2.358

7 srpanj 22,8 638 -294 344 4.034 4.016 8.050 23,38 0,043 0,42 3.211

8 kolovoz 22,4 828 -147 681 4.034 3.583 7.617 11,18 0,089 0,42 2.890

9 rujan 17,3 3.562 1.672 5.233 3.904 3.008 6.912 1,32 0,653 0,42 1.001

10 listopad 12,5 6.334 3.492 9.826 4.034 2.099 6.133 0,62 0,909 0,53 294

11 studeni 7,6 8.655 5.122 13.777 3.904 1.073 4.977 0,36 0,978 0,73 80

12 prosinac 2,6 11.489 7.131 18.620 4.034 688 4.722 0,25 0,992 0,81 30

Ukupno: 72.027 40.197 112.225 47.497 29.532 77.029 11.851

Potrebna energija za rasvjetu, Wt (kWh)

Namjena: Obrazovna ustanova A ukupna instalirana snaga rasvjete u zoni, Pn (W/m2): 4,51

ukupno instalirano parazitno opterećenje elem. kontrole i upravljanja rasvjetom za zonu, Ppc (W/m2): 0,082

ukupna inst. snaga nužne rasvjete u zoni, Pem (W): 0 faktor okupiranosti zone, FO (-): 1 faktor ovisnosti rasvjete o dnevnom osvjetljenju, FD (-): 1 faktor konstantnosti osvjetljenosti, FC (-): 1 radno vrijeme rasvjete za razdoblje dana, tD (h): 1800 radno vrijeme rasvjete za razdoblje noć, tN (h): 200 godišnji rad rasvjete, t0 (h): 2000 panik rasvjeta ugrađena DA automatska regulacija rasvjete ugrađena NE ugrađen sustav kontrole konstantne rasvijeljenosti NE LENI (Lighting Energy Numeric Indicator) (kWh/m2a) 9,5743 Potrebna energija za rasvjetu, Wt (kWh): 8.652

QH,nd = 26.277 (kWh) = 94.598 (MJ)

QC,nd = 11.851 (kWh) = 42.664 (MJ)

Q"H,nd = 29 (kWh/m2a), Q"H,nd,dop = 20 (kWh/m2a)

Q"C,nd = 13 (kWh/m2a), Q"C,nd,dop = 50 (kWh/m2a)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 43

REZULTATI PRORAČUNA ZONE: OSNOVNA ZONA - Toplinska zona zgrade s naj-većom Ak

Proračun konačne i primarne energije (kWh/a) te emisije CO2 (t/kWh)

Grijanje:

Godišnja potrebna energija za grijanje, QH,nd (kWh/a) 26.277

Toplinska energija za grijanje pripremljena sustavom solarnih kolektora Udio toplinske energije za grijanje pripremljena sustavom solarnih kolektora(%) 0,0

Godišnja potrebna toplinska energija za grijanje pripremljena sustavom solarnih ko-lektora QH,nd,sol (kWh/a)

0

Efikasnost podsustava razvoda, ηH,dis 0,98

Efikasnost podsustava predaje, ηH,dis 0,97

Efikasnost podsustava upravljanja, ηH,reg 1,00

Obnovljiva energija za grijanje proizvedena sustavom solarnih kolektora, ErenH,sol (kWh/a)

0

Toplinska energija za grijanje pripremljena osnovnim sustavom Energent osnovnog sustava: Električna energija

Udio toplinske energije za grijanje pripremljen osnovnim sustavom (%) 100,0

Godišnja potrebna toplinska energija za grijanje pripremljena osnovnim sustavom, QH,nd,sust (kWh/a)

26.277

Efikasnost osnovnog podsustava proizvodnje za grijanje, ηH,gen (-) 3,04

OE proizvedena osnovnim sustavom na lokaciji, ErenH,sust (kWh/a) 18.541

OE isporučena osnovnom sustavu, Eren1H,sust (kWh/a) 0

Ukupna efikasnost osnovnog sustava za grijanje, ηH (-) 2,89

Godišnja konačna energija za grijanje osnovnim sustavom, QH,sust (kWh/a) 9.102

Faktor primarne energije energenta osnovnog sustava, fp 1,614

Godišnja primarna en. za grijanje osnovnim sustavom, Eprim,sust(kWh/a) 14.691

Emisija CO2 energenta osnovnog sustava (kg/kWh) 0,2348 Emisija CO2 energenta osnovnog sustava (kg) 2.137,14 Godišnja pomoćna energija za grijanje, Waux (kWh/a) 2.500 Faktor primarne energije energenta pomoćnog sustava, fp 1,614

Godišnja primarna en. pomoćne energije za grijanje, Eprim,H,Waux (kWh/a) 4.035 Emisija CO2 energenta pom. energ. (kg/kWh) 0,23481 Emisija CO2 energenta pom. energ. (kg) 587,03 Godišnja isporučena energija za grijanje, Edel,H (kWh/a) 11.602 Godišnja primarna energija za grijanje, Eprim,H (kWh/a) 18.726 OE proizvedena na lokaciji, Eren (kWh/a) 18.541 OE isporučena sustavu, Eren1 (kWh/a) 0 Emisija CO2 (kg) 2.724

Rasvjeta: Godišnja potrebna energija za rasvjetu, QEL,nd (kWh/a) 8.652

Godišnja isporučena energija za rasvjetu, Edel,ras (kWh/a) 8.652

Faktor primarne energije, Fp 1,614

Godišnja primarna energija za rasvjetu, Eprim(kWh/a) 13.964

Emisija CO2 (kg/kWh) 0,23 Emisija CO2 (kg) 2.031,49

Ventilacija:

Godišnja potrebna pomoćna energija za ventilaciju, Waux,vent (kWh/a) 900 Faktor primarne energije energenta pomoćnog sustava, fp 1,614

Godišnja primarna pomoćna energija za ventilaciju, Eprim,Waux,vent (kWh/a) 1.453 Emisija CO2 energenta pom. energ. (kg/kWh) 0,23481 Emisija CO2 energenta pom. energ. (kg) 211,33

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 44

Pomoćna energija: Godišnja pomoćna energija za grijanje, Waux (kWh/a) 2.500

Godišnja pomoćna energija za hlađenje, Waux (kWh/a) 0

Godišnja pomoćna energija za pripremu PTV, Waux (kWh/a) 0

Godišnja pomoćna energija za ventilaciju, Waux,vent (kWh/a) 900

Rekapitulacija ZONE: OSNOVNA ZONA - Toplinska zona zgrade s najvećom Ak Godišnja isporučena en. za grijanje i PTV, EHW,del (kWh/a) 11.602 Godišnja isporučena en. za hlađenje, EC,del (kWh/a) 0 Godišnja pomoćna en. za rad termoteh. sustava, W (kWh/a) 3.400 Godišnja primarna en. za rad termoteh. sustava, W (kWh/a) 5.488 Ukupna godišnja isporučena energija, Edel,uk (kWh/a) 21.154 Ukupna godišnja primarna energija, Eprim,uk (kWh/a) 34.142 Ukupna godišnja Emisija CO2 (kg) 4.967 OE proizvedena na lokaciji, Eren (kWh/a) 18.541 OE isporučena sustavu, Eren1 (kWh/a) 0

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 45

REZULTATI PRORAČUNA ZA ZGRADU

Specifični trans. toplinski gubitak po jedinici oplošja grijanog dijela zgrade

Dozvoljeni koeficijent transmisijskog toplinskog gubitka H'tr,adj,dozv. = 1,05 (W/m2K) Izračunati koeficijent transmisijskog toplinskog gubitka H'tr,adj = 0,37 (W/m2K)

Specifični transmisijski gubitak zadovoljava zahtjeve tehničkog propisa!

Potrebna toplina za grijanje i hlađenje zgrade

mjesec vanj. temp.

(°C)

sati

(h)

potrebna toplina za grija-

nje,

QH,nd (kWh)

potrebna energija za hla-

đenje,

QC,nd (kWh)

1 siječanj 2,3 744 7.791 36

2 veljača 4,4 672 4.445 61

3 ožujak 8,4 744 1.394 196

4 travanj 13,0 720 276 410

5 svibanj 17,7 744 8 1.283

6 lipanj 21,0 720 0 2.358

7 srpanj 22,8 744 0 3.211

8 kolovoz 22,4 744 0 2.890

9 rujan 17,3 720 16 1.001

10 listopad 12,5 744 593 294

11 studeni 7,6 720 3.489 80

12 prosinac 2,6 744 8.265 30

26.277 11.851

QH,ls = 87.836 (kWh) = 316.211 (MJ) QH,int = 47.497 (kWh) = 170.989 (MJ) QH,sol = 70.922 (kWh) = 255.319 (MJ) QH,gn = 118.419 (kWh) = 426.308 (MJ) QH,nd = 26.277 (kWh) = 94.598 (MJ) QC,nd = 11.851 (kWh) = 42.664 (MJ) Godišnja potrebna toplinska energija za grijanje za stvarne klimatske podatke, QH,nd (kWh/a) 26.277

Bruto obujam grijanog dijela zgrade, V (m3) 6.074,51

Korisna površina, neto ploština grijanog dijela zgrade, Ak (m2) 903,67

Specifična godišnja potrebna toplinska energ. za grijanje za stvarne klimatske podatke, Q"H,nd (kWh/m2a) 29,08

Godišnja potrebna toplinska energija za grijanje za ref. klim. pod., QH,nd,ref (kWh/a) 30.283

Specifična godišnja potrebna toplinska energija za grijanje za referentne klimatske podatke, Q"H,nd (kWh/m2a)

33,51 Dopuštena vrijednost specifične godišnje potrebne toplinske energije za grijanje, Q"H,nd,dop (kWh/m2a), 20,10

prema TPRUETZZ

Godišnja potrebna toplinska energija za hlađenje za stvarne klimatske podatke, QC,nd (kWh/a) 11.851

Godišnja potrebna toplinska energija za hlađenje za referentne klimatske podatke, QC,nd,ref (kWh/a) 10.180

Specifična godišnja potrebna toplinska energija za hlađenje za stvarne klimatske podatke, Q"C,nd (kWh/m2a)

13,11

Dopušt. vrijed. specif. god. potrebne toplinske energije za hlađenje, Q"C,nd,dop (kWh/m2a), prema TPRUETZZ 50,00

Specifični transmisijski topl. gubitak, H'tr,adj (W/m2K) 0,369

Max. dozvoljeni pecifični transmisijski topl. gubitak, H'tr,adj,dozv (W/m2K) 1,050

Potrebna toplinska energija za grijanje zadovoljava zahtjeve tehničkog propisa!

Potrebna toplinska energija za hlađenje zadovoljava zahtjeve tehničkog propisa!

Vrijednosti izračunat godišnje potrebne toplinske energije za grijanje i godišnje potrebne toplinske energije za hlađenje po jedinici ploštine korisne površine zgrade za stvarne klimatske podatke Q’’H,nd [kWh/(m²·a)] i Q’’C,nd [kWh/(m²·a)] (za stambene ili nestambene zgrade) zadovoljavaju i kada su veće od dopuštenih vrijednosti, ukoliko je specifična vrijednosti Eprim niža za najmanje 20% od dopuštene vrijednosti prema članku 9. stavak (7) Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama.

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 46

ENERGETSKI RAZRED ZGRADE Specifična godišnja potrebna toplinska energija za grijanje

Q˝H,nd [kWh/(m2a)]

Specifična godišnja primarna e-nergija

Eprim [kWh/(m2a)]

33,51 40,26

Specifična godišnja isporučena energija Edel [kWh/(m2a)] 24,94

Specifična godišnja emisija CO2 [kg/(m2a)] 5,86

Upisati „nZEB“ ako energetsko svojstvo zgrade (Eprim) zadovoljava zah-tjeve za zgrade gotovo nulte energije propisane važećim TPRUETZZ nZEB

Energetski razred zgrade prema Q''H,nd i prema specifičnoj Eprim Vrsta zgrade prema pretežitoj namjeni iz PEPZEC NN 88/17: zgrade za obrazovanje Klimatsko područje: K Godišnja potrebna toplinska energija za grijanje za ref. klim. pod., QH,nd,ref (kWh/a): 30.282,69 Specifična godišnja potrebna toplinska energija za grijanje za referentne klimatske podatke, Q''H,nd,ref (kWh/m²a): 33,51 Energetski razred zgrade prema Q''H,nd,ref (kWh/a): B Godišnja primarna energija za referentne klimatske podatke, Eprim,ref (kWh/a): 36.381,72 Specifična godišnja primarna energija za referentne klimatske podatke, Eprim,ref/Ak (kWh/m²a): 40,26 Energetski razred zgrade prema Eprim (kWh/a): A+ Kriterij za kontrolu nZEB: Godišnja primarna energija za stvarne klimatske podatke, Eprim (kWh/a): 34.142,49 Korisna površina zgrade, Ak (m2): 903,67 Specifična godišnja primarna energija za stvarne klimatske podatke, Eprim/Ak (kWh/m²a): 37,78 < 55,00 - OSTVARENO Udio obnovljivih izvora u potrebnoj isporučenoj energiji, 46,7% >= 30% - OSTVARENO

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 47

Proračun primarne energije (kWh/a) te emisije CO2 (t/kWh)

Grijanje:

Godišnja potrebna energija za grijanje, QH,nd(kWh/a) 26.277

Godišnja konačna energija za grijanje, QH(kWh/a) 9.102

Godišnja isporučena energija za grijanje, EH,del(kWh/a) 11.602

Godišnja pomoćna energija za grijanje, Waux,H(kWh/a) 2.500

Godišnja primarna energija za grijanje, EH,prim(kWh/a) 18.726

OE proizvedena na lokaciji, ErenH (kWh/a) 18.541

OE isporučena sustavu, Eren1H (kWh/a) 0

Emisija CO2 (kg) 2.724 Hlađenje: Godišnja potrebna energija za hlađenje, QC,nd(kWh/a) 11.851 Godišnja konačna energija za hlađenje, QC(kWh/a) 0

Godišnja isporučena energija za hlađenje, EC,del(kWh/a) 0

Godišnja pomoćna energija za hlađenje, Waux,C(kWh/a) 0

Godišnja primarna energija za hlađenje, EC,prim(kWh/a) 0

OE proizvedena na lokaciji, ErenC (kWh/a) 0

Emisija CO2 (kg) 0 PTV: Potrebna toplinska energija za pripremu PTV, QW,nd (kWh/a) 0 Godišnja konačna energija za pripremu PTV, QW(kWh/a) 0

Godišnja isporučena energija za pripremu PTV, EW,del(kWh/a) 0

Godišnja pomoćna energija za pripremu PTV, Waux,W(kWh/a) 0

Godišnja primarna energija za pripremu PTV, EW,prim(kWh/a) 0

OE proizvedena na lokaciji, ErenW (kWh/a) 0

OE isporučena sustavu, Eren1W (kWh/a) 0

Emisija CO2 (kg) 0,00 Rasvjeta: Potrebna energija za rasvjetu, EL,nd(kWh/a) 8.652

Godišnja primarna energija za rasvjetu, EL,prim(kWh/a) 13.964

Emisija CO2 (kg) 2.031 Ventilacija: Godišnja pomoćna energija za ventilaciju, Waux,vent(kWh/a) 900

Godišnja primarna pomoćna energija za ventilaciju, Eprim,Waux,vent(kWh/a) 1.453

Emisija CO2 (kg) 211 Fotonaponski sustav: Električna energija proizvedena u fotonaponskom sustavu, Eel,PV,out (kWh/a) 0 Godišnja primarna energija fotonaponskog sustava Eprim,el,PV,out (kWh/a) 0 Emisija CO2 (kg) 0 Pomoćna energija za FN sustav, Eel,PV,aux (kWh/a) 0 Primarna energija pomoćne energije FN sustava, Eprim,el,PV,aux (kWh/a) 0

REKAPITULACIJA PRORAČUNA ZA ZGRADU

Godišnja isporučena energija za grijanje i PTV, EHW,del (kWh/a) 11.602

Godišnja isporučena energija za hlađenje, EC,del (kWh/a) 0

God. pomoćna en. za rad termotehničkih sustava, W (kWh/a) 3.400

God. primarna en. za rad termotehničkih sustava, Etermo,prim (kWh/a) 20.178

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 48

Ukupna godišnja isporučena energija, Edel,uk (kWh/a) 21.154

Ukupna godišnja primarna energija, Eprim,uk (kWh/a) 34.142 Ukupna godišnja Emisija CO2 (kg) 4.967 OE proizvedena na lokaciji, Eren (kWh/a) 18.541 OE isporučena zoni, Eren1 (kWh/a) 0

Pretežita namjena zgrade prema toplinskoj zoni najveće površine AK (m²) :

4. zgrade za obrazovanje

Ukupna površina svih topl. zona zgrade, AK (m2) 903,67 Spec. god. primarna en., Eprim/Ak (kWh/m2a) 37,78 Spec. god. primarna en., Eprim,dop/Ak (kWh/m2a) 65,00 Eprim ZADOVOLJAVA zahtjeve tehničkog propisa!

Zadovoljenje kriterija primjene obnovljivih izvora energije

Udio ukupne isporučene energije za rad sustava u zgradi podmireno energijom iz ob-novljivih izvora energije 46,71

[(Eren + Eren1) / (Eren + Edel,uk)] x 100

Udio obnovljivih izvora u isporučenoj energiji, 46,7 >= 20% OSTVARENO

pretežita namjena zgrade: zgrade za obrazovanje Eprim/AK (kWh/m2a) 37,78

Zadovoljavanje kriterija za G0EZ (nZEB) prema udjelu OIE i Eprim/Ak OSTVARENO

Zaštita pregrijavanja prostorija zgrade zbog djelovanja sunčeva zračenja tijekom ljeta

naziv pročelja prostorije orijentacija ploština proče-

lja prost. (m2)

ploština ostaklje-

nja prost. (m2) u sjeni

udio ostakljenja

(%)

stup. prop. topl.

energ. gtot (-) gtot * f (-)

dozvoljeni gtot

* f (-) greška

sjeverno pročelje N 5,65 3,95 х 0,70 0,21 0,15 0,40

sjeverno pročelje N 9,89 6,90 х 0,70 0,28 0,20 0,40

sjeverno pročelje N 9,00 7,50 х 0,83 0,38 0,32 0,40

istočno pročelje E 38,18 24,62 0,64 0,14 0,09 0,15

istočno pročelje E 168,00 75,50 0,45 0,11 0,05 0,15

južno pročelje S 14,60 8,96 0,61 0,14 0,09 0,15

južno pročelje S 5,37 3,75 0,70 0,21 0,15 0,15

južno pročelje S 90,00 7,50 0,08 0,38 0,03 0,15

zapadno pročelje W 168,00 49,10 0,29 0,11 0,03 0,15

zapadno pročelje W 16,60 7,26 0,44 0,21 0,09 0,15

Zaštita protiv sunčeva zračenja zadovoljava zahtjeve tehničkog propisa!

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 49

3. Program kontrole i osiguranja kvalitete PRIMIJENJENI PROPISI I NORME - Zakon o gradnji (NN 153/13, 20/17) - Zakon o prostornom uređenju (NN 153/13) - Zakon o komori arhitekata i komorama inženjera u graditeljstvu i prostornom uređenju (NN 78/15) - Zakon o normizaciji (NN 80/2013) - Zakon o tehničkim zahtjevima za proizvode i ocjeni sukladnosti (NN 80/13, 14/14) i na temelju čl. 26 tog Zakona preuzeti pravilnici - Zakona o zaštiti na radu (NN 71/14) - Zakon o zaštiti od požara (NN 92/10) - Zakon o energetskoj učinkovitosti (NN 127/14) - Pravilnik o tehničkim normativima za projektiranje i izvođenje završnih radova u građevinarstvu (Sl.gl. 21/90) - Pravilnik o jednostavnim i drugim građevinama i radovima (NN 79/14) - Pravilnik o obaveznom sadržaju i opremanju projekata građevina (NN 64/14) - Pravilnik o otpornosti na požar i drugim zahtjevima koji građevine moraju zadovoljiti u slučaju požara (NN 29/13) - Pravilnik o načinu i postupcima gospodarenja otpadom koji sadrži azbest (NN 42/07) - Pravilniku o izradi procjene opasnosti (NN 48/97, 114/02, 126/03, 144/09) - Pravilnik o zaštiti radnika od rizika zbog izlaganja azbestu (NN 40/07) - Pravilnik o uporabi osobnih zaštitnih sredstava (NN 39/06) - Pravilnik o energetskom pregledu zgrade i energetskom certificiranju (NN 88/17) - Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15, 70/18 i 73/18) - Tehnički propis za prozore i vrata (NN 69/06) - Tehnički propis za staklene konstrukcije NN 88/17 - HRN ISO 9836 - Standardi za svojstva zgrada – Definiranje i proračun površina i prostora (ISO 9836:2011) - Performance standards in building – Definition and calculation of area and space indicators (ISO 9836:2011) - HRN EN 13501-1 - Razredba građevnih proizvoda i građevnih elemenata prema ponašanju u požaru -- 1. dio: Razredba prema re-zultatima ispitivanja reakcije na požar (EN 13501-1:2007+A1:2009) - Fire classification of construction products and building elements -- Part 1: Classification using data from reaction to fire tests (EN 13501-1:2007+A1:2009) - HRN EN 13501-5 - Razredba građevnih proizvoda i građevnih elemenata prema ponašanju u požaru -- 5. dio: Razredba prema re-zultatima ispitivanja izloženosti krovova požaru izvana (EN 13501-5:2005+A1:2009) - Fire classification of construction products and building elements -- Part 5: Classification using data from external fire exposure to roofs tests (EN 13501-5:2005+A1:2009) - ETAG 004, 03/00, 06/08, EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING POPIS HRVATSKIH NORMI I DRUGIH TEHNIČKIH SPECIFIKACIJA KOJE UPUĆUJU NA ZAHTJEVE KOJE, U SVEZI S TOPLIN-SKOM ZAŠTITOM, TREBAJU ISPUNITI TOPLINSKO-IZOLACIJSKI GRAĐEVNI PROIZVODI ZA ZGRADE - HRN EN 13162:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od mineralne vune (MW) -- Specifika-cija (EN 13162:2012) Thermal insulation products for buildings -- Factory made mineral wool (MW) products -- Specification (EN 13162:2012) - HRN EN 13163:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekspandiranog polistirena (EPS) -- Specifikacija (EN 13163:2012) - Thermal insulation products for buildings -- Factory made expanded polystyrene (EPS) products -- Specification (EN 13163:2012) - HRN EN 13164:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekstrudirane polistirenske pjene (XPS) -- Specifikacija (EN 13164:2012)- Thermal insulation products for buildings -- Factory made extruded polystyrene foam (XPS) products -- Specification (EN 13164:2012) - HRN EN 13165:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od tvrde poliuretanske pjene (PUR) -- Specifikacija (EN 13165:2012)- Thermal insulation products for buildings -- Factory made rigid polyurethane foam (PU) products -- Specification (EN 13165:2012) - HRN EN 13166:2012 - Toplinsko izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od fenolne pjene (PF) -- Specifikacija (EN 13166:2012)- Thermal insulation products for buildings -- Factory made phenolic foam (PF) products -- Specification (EN 13166:2012) - HRN EN 13167:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ćelijastog (pjenastog) stakla (CG) -- Specifikacija (EN 13167:2012) - Thermal insulation products for buildings -- Factory made cellular glass (CG) products -- Specification (EN 13167:2012) - HRN EN 13168:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od drvene vune (WW) -- Specifikacija (EN 13168:2012) -Thermal insulation products for buildings -- Factory made wood wool (WW) products -- Specification (EN 13168:2012) - HRN EN 13169:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekspandiranog perlita (EPB) -- Spe-cifikacija (EN 13169:2012) -Thermal insulation products for buildings -- Factory made expanded perlite board (EPB) products -- Speci-fication (EN 13169:2012) - HRN EN 13170:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od ekspandiranog pluta (ICB) -- Speci-fikacija (EN 13170:2012) Thermal insulation products for buildings -- Factory made products of expanded cork (ICB) -- Specification (EN 13170:2012) - HRN EN 13171:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od drvenih vlakana (WF) -- Specifika-cija (EN 13171:2012) -Thermal insulation products for buildings Factory made wood fibre (WF) products -- Specification (EN 13171:2012) - HRN EN 13172:2012 - Toplinsko-izolacijski proizvodi -- Vrednovanje sukladnosti (EN 13172:2012) - Thermal insulation products -- Evaluation of conformity (EN 13172:2012) - HRN EN 14314:2013 - Toplinsko-izolacijski proizvodi za instalacije u zgradama i industriji -- Tvornički izrađeni proizvodi od fenolne pjene (PF) -- Specifikacija (EN 14314:2009+A1:2013)

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 50

- HRN EN 14315-1:2013 - Toplinsko-izolacijski proizvodi za zgrade -- Proizvodi od prskane krute poliuretanske (PUR) i poliizocijanura-tne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacija za sustav prskane krute pjene prije ugradnje (EN 14315-1:2013) - HRN EN 14318-1:2013 - Toplinsko-izolacijski proizvodi za zgrade -- Proizvodi od injektirane krute poliuretanske (PUR) i poliizocijanu-ratne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacija za sustav injektiranja krute pjene prije ugradnje (EN 14318-1:2013) - HRN EN 14319-1:2013 - Toplinsko-izolacijski proizvodi za instalacije u zgradama i industriji -- Proizvodi od krute poliuretanske (PUR) i poliizocijanuratne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacije za sustav injektiranja krute pjene prije ugradnje (EN 14319-1:2013) - HRN EN 14320-1:2013 - Toplinsko-izolacijski proizvodi za instalacije u zgradama i industriji -- Proizvodi od prskane krute poliuretan-ske (PUR) i poliizocijanuratne (PIR) pjene oblikovani na mjestu primjene -- 1. dio: Specifikacija za sustav prskane krute pjene prije ugradnje (EN 14320-1:2013)HRN EN 15732:2012 - Proizvodi ispunjeni laganim punjenjem i toplinsko-izolacijski proizvodi za primjenu u građevinarstvu (CEA) – Proizvodi od lakoagregatne kspandirane gline (LWA) (EN 15732:2012) - HRN EN 16069:2012 - Toplinsko-izolacijski proizvodi za zgrade -- Tvornički izrađeni proizvodi od polietilenske pjene (PEF) -- Specifi-kacija (EN 16069:2012) - HRN EN 13172:2012 - Toplinsko-izolacijski proizvodi -- Vrednovanje sukladnosti (EN 13172:2012)Thermal insulation products -- Evaluation of conformity (EN 13172:2012) - HRN EN 1745:2012 - Zidovi i proizvodi za zidanje -- Metode određivanja toplinskih svojstava (EN 1745:2012) -Masonry and masonry products -- Methods for determining thermal properties (EN 1745:2012) NORME ZA ISPITIVANJE NA KOJE UPUĆUJE PROPIS - HRN EN 674:2005 - Staklo u graditeljstvu – Određivanje koeficijenta prolaska topline (U-vrijednost) -- Metoda sa zaštićenom vrućom pločom (EN 674:1997) - HRN EN 1026:2001 - Prozori i vrata -- Propusnost zraka -- Metoda ispitivanja (EN 1026:2000) - HRN EN 12207:2001 - Prozori i vrata -- Propusnost zraka -- Razredba (EN 12207:1999) - HRN EN ISO 12412-2:2004 - Toplinske značajke prozora, vrata i zaslona -- Određivanje koeficijenta prolaska topline metodom vruće komore -- 2. dio: Okviri (EN 12412-2:2003) - HRN EN ISO 12567-1:2002 - Toplinske značajke prozora i vrata -- Određivanje prolaska topline metodom vruće komore -- 1. dio: Prozori i vrata u cjelini (ISO 12567-1:2000; EN ISO 12567-1:2000) - HRN EN 13829:2002 - Toplinske značajke zgrada -- Određivanje propusnosti zraka kod zgrada -- Metoda razlike tlakova (ISO 9972:1996, preinačena; EN 13829:2000) TEHNIČKA SVOJSTVA I DRUGI ZAHTJEVI ZA GRAĐEVNE PROIZVODE (1) Građevni proizvodi koji se ugrađuju u zgradu u svrhu racionalne uporabe energije i toplinske zaštite (u daljnjem tekstu: građevni proizvodi) moraju imati svojstva bitnih značajki propisanih posebnim propisom kojim su uređeni građevni proizvodi. (2) Građevni proizvod može se ugraditi ako: – je namijenjen za ugradnju u zgradu u svrhu racionalne uporabe energije i toplinske zaštite, – je za njega izdana izjava o svojstvima bitnih značajki građevnih proizvoda (dalje u tekstu: izjava o svojstvima) u skladu s posebnim propisom – je propisno označen, – ispunjava druge zahtjeve propisane posebnim propisima kojima se uređuje stavljanje na tržište odnosno stavljanje na raspolaganje na tržište građevnih proizvoda. (3) Vrste građevnih proizvoda jesu: – toplinsko-izolacijski građevni proizvodi, – povezani sustavi za vanjsku toplinsku izolaciju (ETICS), – ziđe i proizvodi za zidanje (4) Građevni i drugi proizvodi koji se ugrađuju u zgradu u svrhu racionalne uporabe energije i toplinske zaštite proizvode se u tvorni-cama izvan gradilišta, te moraju biti međusobno usklađeni na način da nakon izvedbe osiguravaju ispunjavanje zahtjeva određenih važećim propisima. (5) Ocjenjivanje sukladnosti toplinsko-izolacijskih građevnih proizvoda za zgrade provodi se na način uređen u skladu s posebnim zakonom kojim se uređuje područje građevnih proizvoda. ODRŽAVANJE ZGRADE U ODNOSU NA RACIONALNU UPORABU ENERGIJE I TOPLINSKU ZAŠTITU (1) Održavanje zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu mora biti takvo da se tijekom trajanja zgrade oču-vaju njezina tehnička svojstva i ispunjavaju zahtjevi određeni projektom zgrade i Tehničkim propisom o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15), te drugi zahtjevi koje zgrada mora ispunjavati u skladu s posebnim propisom donesenim u skladu sa Zakonom o prostornom uređenju i gradnji. (2) Održavanje zgrade koja je izvedena odnosno koja se izvodi u skladu s prije važećim propisima u odnosu na racionalnu uporabu energije i toplinsku zaštitu mora biti takvo da se tijekom trajanja zgrade očuvaju njezina tehnička svojstva i ispunjavaju zahtjevi odre-đeni projektom zgrade i propisima u skladu s kojima je zgrada izvedena. (1) Održavanje zgrade u smislu racionalne uporabe energije i toplinske zaštite podrazumijeva: – pregled zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu u razmacima i na način određen projektom zgrade i/ili na način određen posebnim propisom donesenim u skladu sa Zakonom o prostornom uređenju i gradnji, – izvođenje radova kojima se zgrada zadržava u stanju određenom projektom zgrade u odnosu na racionalnu uporabu energije i to-plinsku zaštitu i Tehničkim propisom o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15) odnosno propisom u skladu s kojim je zgrada izvedena. (2) Ispunjavanje propisanih uvjeta održavanja zgrade dokumentira se u skladu s projektom zgrade u odnosu na racionalnu uporabu

Proračun je napravljen s računalnim programom EnCert-HR2 proračun - str. 51

energije i toplinsku zaštitu, te: – izvješćima o pregledima i ispitivanjima zgrade i pojedinih njezinih dijelova, – zapisima o radovima održavanja, – na drugi prikladan način ako Tehničkim propisom o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15) ili posebnim propisom donesenim u skladu sa Zakonom o gradnji (NN 153/13) nije što drugo određeno. Za održavanje zgrade dopu-šteno je rabiti samo one građevne proizvode za koje je izdana isprava o sukladnosti prema posebnom propisu ili je uporabljivost dokazana u skladu s projektom zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu i Tehničkim propisom o racio-nalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15). OGRANIČENJA ZRAKOPROPUSNOSTI OMOTAČA ZGRADE, VENTILIRANJE PROSTORA ZGRADE (1) Zgrada mora biti projektirana i izgrađena na način da građevni dijelovi koji čine omotač grijanog prostora zgrade, uključivo mo-žebitne spojnice između pojedinih građevnih dijelova i prozirne elemente koji nemaju mogućnost otvaranja, budu zrakonepropusni u skladu s dosegnutim stupnjem razvoja tehnike i tehnologije u vrijeme izrade projekta. (2) Zrakopropusnost prozora, balkonskih vrata i krovnih prozora mora ispuniti zahtjeve iz tablice 3. iz Priloga »C« Tehničkog pro-pisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15). (3) Iznimno od stavka 2. ovoga članka dopuštena je i veća zrakopropusnost od propisane ako je to potrebno: – da se ne ugrozi higijena i zdravstveni uvjeti, i/ili – zbog uporabe uređaja za grijanje i/ili kuhanje s otvorenim plamenom. (1) Broj izmjena unutarnjeg zraka s vanjskim zrakom kod zgrade u kojoj borave ili rade ljudi treba iznositi najmanje n = 0,5 h-1 ako propisom donesenim u skladu s Zakonom o prostornom uređenju i gradnji kojim se uređuje to područje nije drukčije propisano. (2) U vrijeme kada ljudi ne borave u dijelu zgrade koji je namijenjen za rad i/ili boravak ljudi, potrebno je osigurati izmjenu unutar-njeg zraka od najmanje n = 0,2 h-1. (3) Najmanji broj izmjena zraka iz stavka 1. i stavka 2. ovoga članka mora biti veći u pojedinim dijelovima zgrade ako je to potre-bno: – da se ne ugrozi higijena i zdravstveni uvjeti, i/ili – zbog uporabe uređaja za grijanje i/ili kuhanje s otvorenim plamenom. (1) Ako se za ventiliranje zgrade osim prozora ili umjesto njih koriste i posebni uređaji s otvorima za ventiliranje, tada mora posto-jati mogućnost njihova jednostavnog ugađanja sukladno potrebama korisnika zgrade. (2) Odredba iz stavka 1. ovoga članka ne primjenjuje se kod ugradnje uređaja za ventiliranje s automatskom regulacijom propus-nosti vanjskog zraka. (3) Uređaji za ventiliranje u zatvorenom stanju moraju ispuniti zahtjeve utvrđene u tablici 3. iz Priloga »C« Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 110/08). (1) Ispunjavanje zahtjeva o zrakonepropusnosti iz odredbi članka 20. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15) dokazuje se i ispitivanjem na izgrađenoj zgradi prema HRN EN 13829:2002, metoda određivanja A. (2) Prilikom ispitivanja iz stavka 1. ovoga članka, za razliku tlakova između unutarnjeg i vanjskog zraka od 50 Pa, izmjereni tok zraka, sveden na obujam grijanog zraka, ne smije biti veći od vrijednosti n50 = 3,0 h-1 kod zgrada bez mehaničkog uređaja za provjetravanje, odnosno n50 = 1,5 h-1 kod zgrada s mehaničkim uređajem za provjetravanje. (1) Za višestambene zgrade (stambene zgrade koje imaju više od jednog stana) zahtjevi navedeni u člancima 20., 21., 22., i 23. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15) moraju biti zadovoljeni za svaki stan. (2) Za nestambene zgrade zahtjevi navedeni u člancima 20., 21., 22., i 23. Tehničkog propisa o racionalnoj uporabi energije i to-plinskoj zaštiti u zgradama (NN 128/15) odnose se na omotač grijanog dijela zgrade. PROZORI I VRATA (prema Tehničkom propisu za prozore i vrata (NN 69/06) Tehnička svojstva prozora i vrata moraju biti takva da, u predviđenom roku trajanja građevine, uz propisanu odnosno projektom određenu ugradnju i održavanje, oni podnesu sve utjecaje uobičajene uporabe i utjecaje okoline, tako da građevina u koju su u-građeni ispunjava bitne zahtjeve. Prozori i vrata smiju se ugraditi u građevinu ako ispunjavaju zahtjeve propisane Tehničkim propisom za prozore i vrata (NN 69/06) i ako su za prozor odnosno vrata izdane izjave o sukladnosti u skladu s odredbama posebnog propisa. Dokumentacija s kojom se isporučuju prozori i/ili vrata mora sadržavati: – podatke koji povezuju radnje i dokumentaciju o sukladnosti prozora odnosno vrata i izjave o sukladnosti, odnosno potvrde o suk-ladnosti prema Tehničkom propisu za prozore i vrata (NN 69/06) – podatke u vezi s označavanjem prozora odnosno vrata propisane u Prilogu iz članka 7. stavka 1.Tehničkog propisa za prozore i vrata (NN 69/06) – druge podatke značajne za rukovanje, prijevoz, pretovar, skladištenje, ugradnju, uporabu i održavanje prozora i/ili vrata te za njihov utjecaj na bitna svojstva i trajnost građevine. U slučaju nesukladnosti prozora odnosno vrata s tehničkim specifikacijama ili projektom za taj građevni proizvod, proizvođač pro-zora i/ili vrata mora odmah prekinuti njihovu proizvodnju i poduzeti mjere radi utvrđivanja i otklanjanja grešaka koje su nesuklad-nost uzrokovale. Ako dođe do isporuke nesukladnog prozora i/ili vrata proizvođač odnosno uvoznik mora, bez odgode, o nesukladnosti toga građe-vnog proizvoda obavijestiti sve kupce, distributere, ovlaštenu pravnu osobu koja je sudjelovala u potvrđivanju sukladnosti i Minis-tarstvo zaštite okoliša, prostornog uređenja i graditeljstva. Proizvođač odnosno uvoznik i distributer prozora i/ili vrata, te izvođač građevine, dužni su poduzeti odgovarajuće mjere u cilju održavanja svojstava prozora odnosno vrata tijekom rukovanja, prijevoza, pretovara, skladištenja i njihove ugradnje u građevinu.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 49

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

D) NACRTI

PRILOG:

TLOCRT PRIZEMLJA list 1 TLOCRT KATA list 2 TLOCRT KATA - RAZINA PROZORA list 3 TLOCRT KROVA list 4 PRESJEK A–A list 5

Napomena: Projektant Proračuna racionalne uporabe energije i toplinske zaštite (odnosno Proračuna fizikalnih svojstava zgrade glede racionalne uporabe energije i toplinske zaštite) nije odgovoran za razinu i način razrade nacrta građevine (dobivenih od glavnog projektanta) prema kojima je napravljen ovaj Proračun. Glavni projektant / projektant arhitektonskog dijela projekta dužan je uskladiti gore navedene svoje nacrte (podloge) s Proračunom racionalne uporabe energije i toplinske zaštite i Prikazom mjera zaštite od buke. Nacrti koji su sastavni dio ovog dijela projekta od strane Projektanta racionalne uporabe energije i toplinske zaštite prikazuju zone grijanja građevine, te označuju različite konstrukcije.

12693

50

30

31

8

31

83

0

12290180 12 12 290 12 12 150 12 160 122

5

15

01

225

710 710 710

15

15

15

64

2

12

32

81

24

66 125

504122425

2540

286

32

81

51

82

2936

5 120

374 46 125

10

65

02

3

41

7

41

37

02

80

17

23

73

17

84

710

23

21

30

18

22

54

58

30

16

95

03

21

36

61

06

50

15

6

14

41

HRN EN 1125

49

81

51

72

HRN EN 1125HRN EN 1125HRN EN 1125

SNEGRIJANI PROSTOR

Investitor :

Naziv građevine :

Lokacija :

Broj projekta - TD :

Datum izrade :

Mjerilo : 1:150

List broj : 1

Projektant:Željka Veseljakdipl.ing.arh.

Broj mape :

Zajednička oznaka projekta :

Razina razrade : GLAVNI PROJEKT

Vrsta projekta :

Naziv nacrta :

ARHITEKTONSKI PROJEKT -Proračun fizikalnih svojstava zgrade

siječanj, 2019.

Glavni projektant:Irena Gajšak Tonković,dipl.ing.arh.

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, Mlinarska cesta br.34, Zagreb

DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

Mlinarska cesta br.34, 10 000 Zagrebk.č.br. 333, k.o. CENTAR

PRIKAZ ZONA GRIJANJATLOCRT PRIZEMLJA

05-6/19

26-2019

2

Suradnik : Neno Veseljak, CAD specijalist

+20°C/22°C

+20°C/22°C

PZ1 PZ1 PZ1 PZ1

PZ1 PZ1

PZ1PZ1

Z1

Z1

Z1

Z1

Z1

Z1 Z1

Z1

Z1

Z1

Z1

UZ4 UZ4 UZ4 UZ4

UZ4

UZ4

UZ4 UZ4 UZ4

UZ4P1 P1

P1

P1

UZ4UZ4

UZ4

UZ4

UZ4

UZ4

P1

P1

P1

P1

UZ5

UZ1UZ1UZ1UZ2UZ2

UZ5UZ5UZ5

P1

P1

P1

P1

UZ4UZ4

UZ4

UZ5UZ5

P3

UZ5

P3

UZ5

UZ5

UZ5

P3

UZ5

P3UZ5

P1

P2P4

UZ3

M5M5

M5UZ1

Opis svih elemenata zaštite od pregrijavanja tijekom ljeta koji se koriste na prozirnim građevnim dijelovima:Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60.Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i maksimalnim g = 0,60.Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od sunca je riješena s mutnim neprozirnim staklom s g = 0,60.Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite od sunca je riješena sa staklom koje ima g = 0,33.

31

8

2800

15

00

30

15

143

0

3521201212 572

501 12 120

55

0

25

573

2

25

30

15

14

110

46

42

5

10

20

25

10

36

3

669

50 660 50 660 50 660 50 660 50 2323

80 646 64 646 64 646 64 646 80

2936

18

41

92

19

41

05

94

24

51

24

22

32

32

28

23

13

41

94

30

15

143

03

18

252

32

3

19

63

18

41

92

19

41

05

94

24

51

24

22

32

33

78

13

41

90

23

37

75

93

30 300 100 335 330 6423 252311501182

12

33

33

45

6

23

67

3

21

09

HRN EN 179

HRN EN 179

HRN

EN 1

79

HRN

EN 1

79

HRN

EN 1

79

EI 90-C500

500

EI

90

min90

NEGRIJANI PROSTOR S

+20°C/22°C

+20°C/22°C

Z2

Z2

Z2Z2Z2bZ2b

Z2

Z2a

Z2a

Z2a

Z2a

Z2aZ2aZ2aZ2aZ2a

Z2

Z2a

Z2a

Z2a

Z2a

Z2

Z2Z2 Z2 Z2

M2

M2

M2 M2 M2 M2 M2

M2

M2

M1

M1M1

M1

M1

M1

M1

M1

UZ1 UZ1 UZ1 UZ1UZ4 UZ4

P5

P5

P5

M3

UZ5

UZ5

P5P6

UZ4

UZ5

UZ5UZ5

P6

P6

UZ5

UZ4

UZ4

UZ5

M6M4

M5

M5

M5UZ4

Investitor :

Naziv građevine :

Lokacija :

Broj projekta - TD :

Datum izrade :

Mjerilo : 1:150

List broj : 2

Projektant:Željka Veseljakdipl.ing.arh.

Broj mape :

Zajednička oznaka projekta :

Razina razrade : GLAVNI PROJEKT

Vrsta projekta :

Naziv nacrta :

ARHITEKTONSKI PROJEKT -Proračun fizikalnih svojstava zgrade

siječanj, 2019.

Glavni projektant:Irena Gajšak Tonković,dipl.ing.arh.

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, Mlinarska cesta br.34, Zagreb

DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

Mlinarska cesta br.34, 10 000 Zagrebk.č.br. 333, k.o. CENTAR

PRIKAZ ZONA GRIJANJATLOCRT KATA

05-6/19

26-2019

2

Suradnik : Neno Veseljak, CAD specijalist

Opis svih elemenata zaštite od pregrijavanja tijekom ljeta koji se koriste na prozirnim građevnim dijelovima:Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60.Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i maksimalnim g = 0,60.Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od sunca je riješena s mutnim neprozirnim staklom s g = 0,60.Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite od sunca je riješena sa staklom koje ima g = 0,33.

2800

1620

2936

669

489

50 660 50 660 50 660 50 660 502323

80 646 64 646 64 646 64 646 80

2936

NEGRIJANI PROSTOR S

+20°C/22°C

+20°C/22°C

Z2a

Z2a

Z2a

Z2a

Z2a

Z2a

Z2a

Z2a

Z2a Z2a Z2a Z2a Z2a

Z3Z3 Z3 Z3 Z3

K2

K2

K2

K2

K2

K2K2a

K2a

Investitor :

Naziv građevine :

Lokacija :

Broj projekta - TD :

Datum izrade :

Mjerilo : 1:150

List broj : 3

Projektant:Željka Veseljakdipl.ing.arh.

Broj mape :

Zajednička oznaka projekta :

Razina razrade : GLAVNI PROJEKT

Vrsta projekta :

Naziv nacrta :

ARHITEKTONSKI PROJEKT -Proračun fizikalnih svojstava zgrade

siječanj, 2019.

Glavni projektant:Irena Gajšak Tonković,dipl.ing.arh.

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, Mlinarska cesta br.34, Zagreb

DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

Mlinarska cesta br.34, 10 000 Zagrebk.č.br. 333, k.o. CENTAR

PRIKAZ ZONA GRIJANJATLOCRT KATA - RAZINA PROZORA

05-6/19

26-2019

2

Suradnik : Neno Veseljak, CAD specijalist

Opis svih elemenata zaštite od pregrijavanja tijekom ljeta koji se koriste na prozirnim građevnim dijelovima:Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60.Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i maksimalnim g = 0,60.Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od sunca je riješena s mutnim neprozirnim staklom s g = 0,60.Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite od sunca je riješena sa staklom koje ima g = 0,33.

K2

31

NEGRIJANI PROSTOR S

K2

K2

K2

K2

K2

K2K2a

K2a

K1

K1

K1

K1

K1

K1

K1

K1

K1

K1

K1

Investitor :

Naziv građevine :

Lokacija :

Broj projekta - TD :

Datum izrade :

Mjerilo : 1:150

List broj : 4

Projektant:Željka Veseljakdipl.ing.arh.

Broj mape :

Zajednička oznaka projekta :

Razina razrade : GLAVNI PROJEKT

Vrsta projekta :

Naziv nacrta :

ARHITEKTONSKI PROJEKT -Proračun fizikalnih svojstava zgrade

siječanj, 2019.

Glavni projektant:Irena Gajšak Tonković,dipl.ing.arh.

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, Mlinarska cesta br.34, Zagreb

DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

Mlinarska cesta br.34, 10 000 Zagrebk.č.br. 333, k.o. CENTAR

PRIKAZ ZONA GRIJANJATLOCRT KROVA

05-6/19

26-2019

2

Suradnik : Neno Veseljak, CAD specijalist

Opis svih elemenata zaštite od pregrijavanja tijekom ljeta koji se koriste na prozirnim građevnim dijelovima:Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60.Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i maksimalnim g = 0,60.Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od sunca je riješena s mutnim neprozirnim staklom s g = 0,60.Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite od sunca je riješena sa staklom koje ima g = 0,33.

K2

IPE 550

27

6

28

66

02

60

18

611

6

41

6

30

0

60

0

1500

39

0

39

0

35

31

24

038

39

0

35

22

2

21

79

5

20

0

16

35

5

10

0

80

NEGRIJANI PROSTOR

+20°C/22°C

+20°C/22°C

K1K1K1

Z2a

Z2a

PZ1

Z1PZ1

K2K2K2

Z3

Z3

UZ1

UZ5UZ5

UZ4

P1 P1 P1P3P3P3

P5P5M2 M3M1M1M1

Investitor :

Naziv građevine :

Lokacija :

Broj projekta - TD :

Datum izrade :

Mjerilo : 1:150

List broj : 5

Projektant:Željka Veseljakdipl.ing.arh.

Broj mape :

Zajednička oznaka projekta :

Razina razrade : GLAVNI PROJEKT

Vrsta projekta :

Naziv nacrta :

ARHITEKTONSKI PROJEKT -Proračun fizikalnih svojstava zgrade

siječanj, 2019.

Glavni projektant:Irena Gajšak Tonković,dipl.ing.arh.

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, Mlinarska cesta br.34, Zagreb

DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU

Mlinarska cesta br.34, 10 000 Zagrebk.č.br. 333, k.o. CENTAR

PRIKAZ ZONA GRIJANJAPRESJEK A - A

05-6/19

26-2019

2

Suradnik : Neno Veseljak, CAD specijalist

Opis svih elemenata zaštite od pregrijavanja tijekom ljeta koji se koriste na prozirnim građevnim dijelovima:Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60.Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i maksimalnim g = 0,60.Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od sunca je riješena s mutnim neprozirnim staklom s g = 0,60.Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite od sunca je riješena sa staklom koje ima g = 0,33.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 50

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

E) KATALOG DOBRO RJEŠENIH TOPLINSKIH MOSTOVA NA ZGRADAMA - prilog D Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/2015, 070/2018, 073/2018, 086/2018)

PRILOG:

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 51

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 52

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 53

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 54

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 55

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 56

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 57

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 58

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 59

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA MLINARSKA CESTA br.34, 10 000 ZAGREB

Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u zdravstvu pri Školi za medicinske sestre Mlinarska

Vrsta projekta: ARHITEKTONSKI PROJEKT - Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB, k.č.br. 333 k.o. CENTAR

Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 60

Dio mape: dio a Proračun racionalne uporabe energije i toplinske zaštite

"STUDIO LINEAMENTA" d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh. Projektant: Željka Veseljak, dipl.ing.arh. Suradnik: Neno Veseljak, CAD specijalist

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta br.24A, tel/mob: 091/ 515-3810

www.lineamenta.hr, e-mail: studio@lineamenta.hr, OIB: 52601971360

Projektantski ured :

STUDIO LINEAMENTA d.o.o.

ČULINEČKA CESTA br.24A

10 040 ZAGREB

OIB: 52601971360

e-mail: studio@lineamenta.hr

Investitor :

ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34,

10 000 ZAGREB,

OIB: 63702214100

Naziv građevine / zahvata u prostoru :

DOGRADNJA DVORANE ZA ERGONOMIJU

RADNOG PROSTORA U ZDRAVSTVU PRI

ŠKOLI ZA MEDICINSKE SESTRE MLINARSKA U SVRHU USPOSTAVE REGIONALNOG CENTRA

KOMPETENTNOSTI U STRUKOVNOM

OBRAZOVANJU I OSPOSOBLJAVANJU, SEKTOR

ZDRAVSTVA

Lokacija građevine / zahvata u prostoru :

MLINARSKA CESTA br.34,

10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR

Zajednička oznaka projekta (ZOP) : Dokumentacijski broj projekta (TD) :

05-6/19 26-2019

Redni broj mape : Razina razrade :

MAPA 2 / dio b GLAVNI PROJEKT

Strukovna odrednica projekta :

ARHITEKTONSKI PROJEKT

Naziv projektiranog dijela građevine :

PRIKAZ MJERA ZAŠTITE OD BUKE

Projektanti :

PROJEKTANT : SURADNIK

Željka Veseljak, dipl.ing.arh., A-3245 Neno Veseljak, CAD specijalist

Mjesto i datum projekta : Odgovorna osoba u projektantskom uredu :

Zagreb, siječanj 2020. godine direktor:

Željka Veseljak,

dipl.ing.arh.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 2

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Računska analiza i ocjena akustičkih karakteristika građevinskih konstrukcija izrađena je prema slijedećim

pravilnicima:

- Zakon o prostornom uređenju (NN 153/2013, 065/2017, 114/2018, 039/2019, 098/2019)

- Zakon o gradnji (NN 153/2013, 020/2017, 039/2019, 125/2019)

- Zakon o normizaciji (NN 080/2013)

- Zakon o građevnim proizvodima (NN 076/2013, 030/2014, 130/2017, 039/2019)

- Tehnički propis o građevnim proizvodima (NN 035/2018, 104/2019)

- Zakon o tehničkim zahtjevima za proizvode i ocjenjivanju sukladnosti (NN 080/2013, 014/2014)

- Zakon o zaštiti od buke (NN 030/2009, 055/2013, 153/2013, 041/2016, 114/2018)

- Pravilnik o najvišim dopuštenim razinama buke u sredini u kojoj ljudi rade i borave (NN 145/2004)

- Pravilnik o zaštiti radnika od izloženosti buci na radu (NN 046/2008)

- HRN U.J6.001 (1982.) - akustika u građevinarstvu: Termini i definicije

- HRN U.J6.151 (1982.) - akustika u građevinarstvu: Standardne vrijednosti za ocjenu zvučne izolacije

- HRN U.J6.201 (1989.) - akustika u građevinarstvu: Tehnički uvjeti za projektiranje i građenje zgrada

- HRN U.J6.153 (1989.) - akustika u građevinarstvu: Metode izračunavanja zvučne izolacije jednim brojem

- HRN U.J6.205 (1990.) - akustika u građevinarstvu: Akustičko zoniranje prostora

- HRN U.J6.216 (1982.) - akustika u građevinarstvu: Akustička kvaliteta malih i srednje velikih prostorija

- DIN 4109 Schallschutz im Hochbau (zvučna zaštita u visokogradnji): Beiblatt 1 i 2 zu DIN 4109/89

- Pravilnik o djelatnostima za koje je potrebno utvrditi provedbu mjera za zaštitu od buke (NN 091/2007)

- Pravilnik o mjerama zaštite od buke izvora na otvorenom prostoru (NN 156/2008)

- HRN EN ISO 16283-1:2014 (zvučna izolacija)

Napomena izvođaču:

Analiza zaštite od buke izrađena je na osnovu navedenih važećih normativa i pravilnika kojih se treba pridržavati i

izvođač pri izvedbi. U slučaju promjene vrste materijala i koncepcije sastava konstrukcije, novi materijali ne smiju

imati slabije karakteristike od karakteristika prikazanih ovom analizom. Svi ugrađeni materijali trebaju imati ateste

od u Hrvatskoj mjerodavnih institucija.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 3

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

SADRŽAJ

a) OPĆENITO str. 4

1. Kategorizacija, lokacija str. 4

2. Prostorna dispozicija, konstrukcija str. 4

3. Strojarske instalacije - grijanje, hlađenje, ventilacija, klimatizacija str. 6

4. Zahtjevi str. 9

b) IZVEDBA str. 10

1. Podna konstrukcija – plivajući pod str. 10

2. Prodori instalacija kroz zidove i međukatne konstrukcije str. 11

3. Pregradni zidovi i pregrade između različitih korisnika (vanjske konstrukcije) str. 11

4. Prozori i vrata str. 12

5. Akustička obrada prostora str. 13

6. Izvedba kritičnih konstrukcija građevine str. 14

7. Program kontrole i osiguranja kvalitete str. 14

c) RAČUNSKE PREDPOSTAVKE: str. 15

1. Zid bez vrata između učionica (višenamjenska učionica, višenamjenska prostorija za

edukaciju)

str. 15

2. Zid bez vrata između učionice i kabineta (višenamjenska učionica / kabinet) str. 16

3. Zid s vratima između učionice ili kabineta i hodnika (Dw,min) str. 17

4. Zid prema bučnoj pogonskoj prostoriji str. 18

5. Međukatna konstrukcija između učionice ili kabineta i dvorane str. 20

6. Međukatna konstrukcija prema donjoj bučnoj prostoriji str. 21

7. Međukatna konstrukcija str. 22

d) VANJSKE KONSTRUKCIJE str. 23

e) VANJSKI IZVORI BUKE str. 26

f) BUKA STROJARSKIH JEDINICA str. 28

g) AKUSTIČKA OBRADA str. 33

h) ZAKLJUČAK str. 37

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 4

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

a) OPĆENITO

1. Kategorizacija, lokacija:

Na parceli koja se nalazi u Zagrebu, Mlinarska ulica br.34, na k.č.br. 333 k.o. Centar, se predviđa DOGRADNJA

DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU (PRI ŠKOLI ZA MEDICINSKE

SESTRE MLINARSKA). Ovim projektom je predviđena izgradnja dvorane, prostorija za edukaciju i popratnih

prostorija kao dogradnja odnosno dio Škole za medicinske sestre Mlinarska, a namjena cijele dogradnje je zgrada za

obrazovanje sa svim pratećim zatvorenim i otvorenim prostorima. Etažnost zgrade je: prizemlje+kat. Zgrada se

dograđuje sa istočne strane školskog kompleksa.

Teren na parceli je u padu po zapada prema istoku, prema Medvedgradskoj ulici. Sukladno važećoj prostorno planskoj

dokumentaciji (Generalnom urbanističkom planu Grada Zagreba), predmetna građevina nalazi se unutar zone javne i

društvene namjene – školska namjena (D5). Predmetna parcela omeđena je Mlinarskom ulicom na zapadu, te

Medvedgradskom ulicom na istoku. Dogradnja je okrenuta prema Medvedgradskoj ulici. Okolna izgradnja je prema

važećoj prostorno planskoj dokumentaciji u zoni mješovite pretežito poslovne namjene (M2).

U postojećoj građevini i njenoj dogradnji se nalazi jedan korisnik – škola za medicinske sestre.

Obzirom na tip građevine (dogradnja dvorane u sklopu škole za medicinske sestre) ona neće biti uzrokom narušavanja

mira u okolišu. Dogradnja zgrade se nalazi u sklopu postojećeg školskog kompleksa, u centru grada Zagreba.

Najviše dopuštene ocjenske razine buke imisije u otvorenom prostoru prema HRN U.J6.201/89 i Pravilniku o najvišim

dozvoljenim razinama buke u sredini u kojima ljudi rade i borave NN 145/04 dane u tablici 1 su LRAeq = 50 dB(A)

noću i LRAeq = 65 dB(A) danju, za zonu mješovite, pretežito poslovne namjene sa stanovanjem.

Dopuštena razina buke s obzirom na vrstu djelatnosti:

- manje zahtjevni uredski poslovi, pretežno rutinski umni rad koji zahtjeva usredotočenje ili neposredno govorno i/ili

telefonsko komuniciranje, komunikacijske centrale (kabinet i sl.)

Leq = 60 dB(A) - (a) razina buke na radnom mjestu koja potječe od proizvodnih izvora odnosno

Leq = 50 dB(A) - (a) razina buke na radnom mjestu koja potječe od neproizvodnih izvora.

Prema članku 11. Pravilnika o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i borave (NN

145/2004) najviše dopuštene ekvivalentne razine buke u zatvorenim prostorijama posebne namjene za izložbene

prostorije, predavaonice i slične prostorije su 35 dB(A) – višenamjenska učionica, višenamjenska prostorija za

edukaciju, dvorana.

U okolini građevine ne postoje izraziti izvori buke, a niti će predmetna dogradnja svojom namjenom glede buke

ugrožavati okolinu. Vanjske izvore buke predstavlja kolni promet na obližnjim ulicama. Najmanja udaljenost

stambene zgrade od predmetnog zahvata u prostoru je cca 17 m.

Navedeni sadržaji i namjena zgrade (dogradnja dvorane škole za medicinske sestre), te njena udaljenost od drugih

sadržaja naseljenog područja ne ometaju okolne sadržaje i namjenu (prije svega stanovanje) bukom, prometom,

neugodnim mirisima, prašinom i sl.

Građevina je predviđena za dnevno korištenje, odnosno namjena građevine sa svojom djelatnosti će se obavljati samo

danju i uvečer (između 07:00 i 23:00 sata), a nikako u noćnom terminu.

2. Prostorna dispozicija, konstrukcija

Kompleks se sastoji od: građevine škole povezane s učeničkim domom, prostora amfiteatra i drvenog objekta u kojem

se nalaze nastavni kabineti. Medicinska škola, đački dom i drveni objekt orijentirani su na Mlinarsku ulicu, dok je

građevina amfiteatra uz Medvedgradsku ulicu. Južno od građevine amfiteatra, planira se dogradnja dvorane za

ergonomiju. Dogradnja je sa školom povezana spojnim hodnikom na etaži kata

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 5

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Dogradnja se sastoji od gornje etaže (kata) gdje je smještena dvorana za ergonomiju s pratećim sanitarijama i

kabinetima- spremištima medicinske opreme, te donje etaže (prizemlja) gdje su višenamjenske prostorije za edukaciju,

višenamjenska učionica s pripadajućim kabinetom, sanitarije i spremište.

Na etaži kata smještena je dvorana za ergonomiju koja će se prema potrebi moći podijeliti pokretnim panelima u dva

dijela radi istovremenog održavanja različitih predavanja.

Nosiva konstrukcija su armiranobetonski zidovi debljine 20cm, 25cm i 30cm, ukrućeni punim armiranobetonskim

pločama debljine 22cm. Zgrada je temeljena na trakastim temeljima koji su povezani podnom armiranobetonskom

pločom debljine 20cm.

U podu prema tlu grijanih prostorija prizemlja ispod lagano armirane betonske podloge (tzv. cementne glazure) su

ugrađene ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 10 cm, te 2 cm elastificiranog

ekspandiranog polistirena EPS-T koji je u funkciji i toplinske i zvučne izolacije.

U podu prema tlu grijanih prostorija kata ispod lagano armirane betonske podloge (tzv. cementne glazure) su ugrađene

ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 5 cm, te 2 cm elastificiranog

ekspandiranog polistirena EPS-T koji je u funkciji i toplinske i zvučne izolacije, dok se ispod podne ploče ugrađuje

još sloj ekstrudiranog polistirena XPS debljine 5 cm.

U podu prema tlu negrijanog prostora spremišta u prizemlju ispod lagano armirane betonske podloge (tzv. cementne

glazure) su ugrađene ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 6 cm, te 2 cm

elastificiranog ekspandiranog polistirena EPS-T koji je u funkciji i toplinske i zvučne izolacije. Toplinska izolacija je

postavljena radi sprečavanja toplinskih mostova na konstrukcijama.

Međukatna konstrukcija je predviđena kao puna armiranobetonska stropna ploče debljine 22 cm. Sve međukatne

konstrukcije i podovi na tlu predviđene su u izvedbi s prigušnim slojem elastificiranog ekspandiranog polistirena kao

prvenstveno zvučnom izolacijom između etaža ("plivajući pod"). U plivajućem podu međukatnih konstrukcija osim 2

cm elastificiranog ekspandiranog polistirena EPS-T se nalaze još dodatno i ploče samogasivog ekspandiranog

polistirena EPS-150 (ili EPS-100) debljine 1cm odnosno 5cm (ovisno o poziciji na kojoj se nalazi).

U podgled međukatne konstrukcije iznad otvorenog gdje je predviđeno ventilirano pročelje, prema grijanom prostoru

iznad predviđena je postava toplinske izolacije sa fasadnim pločama mineralne vune za ventilirano pročelje debljine

16 cm (ploče kao Knauf Insulation ploče za ventilirane fasade s crnim voalom NaturBoard Ventacusto GVB ili

NaturBoard Venti GVB ili jednakovrijedan materijal), sa završnom oblogom ventiliranog pročelja na podkonstrukciji

prema izboru projektanta, sve izvedeno prema preporukama proizvođača ventiliranog pročelja.

U podgled međukatne konstrukcije iznad negrijanog prostora spremišta u prizemlju, prema grijanom prostoru iznad

predviđena je postava toplinske izolacije fasadnim pločama od mineralne vune (kao Knauf Insulation ploče za

kontaktne fasade FKD S Thermal ili jednakovrijedan materijal) debljine 5 cm, sa završnom polimercementnom

žbukom, kao kompaktni fasadni sustav, sve izvedeno prema preporukama proizvođača za izvedbu žbuke na pločama

mineralne vune (ETICS fasada). U plivajućem podu iznad osim 2 cm elastificiranog ekspandiranog polistirena EPS-

T nalaze se još dodatno i ploče samogasivog ekspandiranog polistirena EPS-150 (ili EPS-100) debljine 1cm.

Krov iznad dvorane je laki ravni zeleni krov sa čeličnom konstrukcijom kao slagani krov, sa kompaktnim pločama od

tvrde mineralne vune debljine 25 cm položenom na trapezni profilirani lim (kao Knauf Insulation ploče za ravne

krovove SMARTROOF thermal debljine 15 cm + Knauf Insulation ploče za ravne krovove SMARTROOF TOP

debljine 10 cm ili jednakovrijedni materijali). Ispod toplinske izolacije je potrebno postaviti parnu branu, dok je iznad

predviđena hidroizolacijska traka na bazi FPO/TPO-a. Iznad hidroizolacije je predviđen ploča ekstrudiranog

polistirena XPS debljine 5 cm kao dodatna zaštita hidroizolacije od slojeva zelenog krova. Navedeni laki krov je

predviđen kao zeleni krov, sve izvedeno prema preporukama proizvođača zelenih krovova.

Iznad nižeg dijela kata postoji ravni teški neprohodni krov sa teškom armiranobetonskom pločom debljine 16 cm kao

nosivim dijelom krova. Toplinska izolacija krova je predviđena pločama ekstrudiranog polistirena XPS debljine 30

cm položenim na armiranobetonsku ploču, te hidroizolacijom krova postavljenom iznad toplinske izolacije i parnom

branom ispod toplinske izolacije. Kao završna obloga krova je predviđen zaštitni sloj oblutaka.

Vanjski zidovi od armiranog betona su obloženi toplinskom izolacijom sa fasadnim pločama mineralne vune za

ventilirano pročelje debljine 14cm u prizemlju i 16cm na katu (ploče kao Knauf Insulation ploče za ventilirane fasade

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 6

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

s crnim voalom NaturBoard Ventacusto GVB ili NaturBoard Venti GVB ili jednakovrijedan materijal), sa završnom

oblogom ventiliranog pročelja na podkonstrukciji prema izboru projektanta, sve izvedeno prema preporukama

proizvođača ventiliranog pročelja.

Kod podnožja vanjskih zidova izloženih prskanju kiše toplinska izolacija se izvodi s pločama ekstrudiranog polistirena

XPS minimalne debljine 12cm odnosno 14cm, sa završnom polimercementnom žbukom ili sl., kao kompaktni fasadni

sustav sokla iznad tla / terasa.

Vanjski zid zapadnog pročelja zgrade iznad razine prvog kata je armiranobetonski predviđen kao ETICS fasada, s

predviđenom toplinskom izolacijom od mineralne vune za ETICS fasade (kao Knauf Insulation ploče za kontaktne

fasade FKD S Thermal) debljine 16 cm, sa završnom polimercementnom žbukom, kao kompaktni fasadni sustav, sve

izvedeno prema preporukama proizvođača za izvedbu žbuke na pločama mineralne vune (ETICS fasada).

Armiranobetonski zid grijanog prostora prema negrijanom prostoru spremišta u prizemlju su obloženi toplinskom

izolacijom fasadnim pločama od mineralne vune (kao Knauf Insulation ploče za kontaktne fasade FKD S Thermal ili

jednakovrijedan materijal) debljine 10 cm, sa završnom polimercementnom žbukom, kao kompaktni fasadni sustav,

sve izvedeno prema preporukama proizvođača za izvedbu žbuke na pločama mineralne vune (ETICS fasada).

Zidovi prema tlu predviđeni sa dodatnom toplinskom izolacijom s vanjske strane nosivog zida, toplinsko izolacijskim

pločama ekstrudiranog polistirena XPS debljine 12 cm te zaštićeni hidroizolacijom.

Zid između grijanog i negrijanog dijela prizemlja koji je predviđen kao laka montažna pregradna stijena je od

gipskartonskih ploča kao tipa Knauf Diamant ploče na metalnoj podkonstrukciji (debljine 15 cm), s ispunom

međuprostora mineralnom vunom (kao Knauf Insulation filc za pregradne zidove TI 140 W, Knauf Insulation ECOSE

filc za pregradne zidove DECIBEL ili jednakovrijedni materijal debljine 10 cm), s obavezno postavljenom parnom

branom s toplije strane toplinske izolacije.

Unutarnji novi pregradni zidovi su predviđeni kao lake montažne pregradne stijene od gipskartonskih ploča na

metalnoj podkonstrukciji (debljine minimalno 10 cm), s ispunom međuprostora mineralnom vunom (kao Knauf

Insulation filc za pregradne zidove TI 140 W, Knauf Insulation ECOSE filc za pregradne zidove DECIBEL ili

jednakovrijedni materijal debljine 5 cm). Pregrade je potrebno izvoditi do nosive konstrukcije, iznad razine spuštenog

stropa (ukoliko on postoji kao interijerska završna obrada stropa).

Kod zidova gdje je potrebna bolja zvučna izolacija između različitih prostorija predviđena je upotreba gipskartonskih

ploča kao tipa Knauf Diamant ploče umjesto običnih gipskartonskih ploča (zidovi učionice, dvorane, prostorija za

edukaciju, kabineta i sl) debljine 15 cm ispunjenu mineralnom vunom debljine 10cm.

Iz razloga zvučne izolacije se projektirana debljina zida ne smije tanjiti (prilikom montiranja instalacija), te je iz

razloga provođenja instalacija potrebno izvoditi dodatni parapetni zid (u prostorijama sanitarija). Sva unutarnja

stolarija je predviđena drvena.

3. Strojarske instalacije - grijanje, hlađenje, ventilacija, klimatizacija

Kratki opis iz strojarskog projekta:

4.1.1.GRIJANJE I HLAĐENJE- VRV SUSTAV

Za potrebe grijanja dijela građevine; predviđen je direktni koncept grijanja i hlađenja putem zrakom hlađenih dizalica topline

s promjenjivimvolumenomradne tvari (VRV sustav). VRV sustav s direktnom ekspanzijom radnog medija sastoji se od većeg

broja unutarnjih jedinica(isparivača/kondenzatora) spojenih na jednu vanjsku (kondenzator + kompresor). …

Vanjske jedinice smještene su u zasebnoj prostoriji u prizemlju. Moduli se postavljaju na postolje izrađeno iz čeličnih

kvadratnih profila. Između postolja i jedinice postavljaju se gumeni antivibracijski podlošci. Prilikom postavljanja jedinice

potrebno se pridržavati minimalnih potrebnih udaljenoisti od bočnih zidova, te minimalne potrebne visine ugradnje.

Ovisno o konfiguraciji prostorija potrebnih za grijanje/hlađenje, izabrane su slj. unutarnje jedinice VRV sustava:

Parapetna podna jedinica… zidna jedinica… ili kazetna četverosmjerna jedinica - ugradbena.

4.1.2.GRIJANJE VODENI SUSTAV

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 7

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Za pripremu ogrjevne i rashladne vode za potrebe podnog grijanja predviđen je kondenzacijski kotao modularne izvedbe

ukupne toplinske snage 230kW, tipa Power Plus Box 1002 P EXT, proizvođača BERETTA, EWAQ025CWP. Kotao se nalazi

na krovu prema postojećem dijelu škole.

VODENO PODNO GRIJANJE/HLAĐENJE SANITARIJA I GARDEROBA

Grijanje sanitarija i grderoba riješeno je podnim površinskim grijanjem. Sustav podnog grijanja priključuje se na toplinski

sustav kondenzacijskog kotla na krovu zgrade. Predviđeni temperaturni režim podnog grijanja iznosi 40/37ºC. …

GRIJANJE DVORANE

Grijanje dvorane riješeno je pomoću radijatora koji su temeljni sustav i ventilacijske komore koja je dodatni sustav.

4.1. VENTILACIJA Sve prostorije koje nemaju vlastite prozore za provjetravanje, trebaju biti ventilirane prisilno pomoću ventilatora i ventilacijskih

kanala. Zadatak ventilacije u takvim prostorijama je izmjena zraka radi održavanja vlažnosti zraka, čistoće i kretanja zraka po

normativima koji odgovaraju potrebama čovjekovog zdravlja i ugodnog boravka. ….

4.2.1. VENTILACIJA DVORANE ZA ERGONOMIJU

Za potrebe ventiliranja dvorane za ergonomiju i kabineta u prizemlju predviđena je prisilna ventilacija putem klima komore

(KK1) s povratom topline (rekuperatorska jedinica),. Rekuperatorska - ventilacijska jedinica kompaktnemonoblock izvedbe,

opremljena je sa visokoučinskim pločastim rekuperatorom (temperaturna učinkovitost 89%), tlačnim i odsisnim elektronički

upravljanim ventilatorima, filterima klase M5 i prigušivačima na tlačnom i odsisnom kanalu, te svim potrebnim elementima

za zaštitu, kontrolu i regulaciju uređaja.

Klima komora je smještena na ravnom dijelu krova prema postojećem dijelu građevine. Prilikom postavljanja jedinice

potrebno se pridržavati minimalnih potrebnih servisnih udaljenoisti od bočnih zidova, te minimalne potrebne visine ugradnje.

Zrak se od komore do usisnih i odsisnih mjesta distribuira putem limenih pocinčanih kanala, odgovarajućih dimenzija,

vođenih u spuštenom stropu. Kanali svježeg i otpadnog zraka izoliraju se paronepropusom izolacijom od kamene vune tipa

Larock, kao proizvod Rockwool, debljine prema specifikaciji.

Odsisavanje zraka vrši se preko zračnih odsisnih ventila tipa LVS, proizvod kao TROX,. Na granama tlačnih kanala ugrađeni

su regulatori konstantnog protoka, tipa VFL, proizvod kao TROX, za automatsku regulaciju protoka. Kako bi se omogučilo

strujanje zraka od mjesta ubacivanja do mjesta odsisavanja (sanitarije) zraka vrata između prostorija potrebno je podrezati

ili na ista ugraditi adekvatne prestrujne rešetke.

4.2.1. VENTILACIJA VIŠENAMJENSKIH PROSTORIJA ZA EDUKACIJU

Za potrebe ventiliranja višenamjenskih prostorija u prizemlju predviđena je prisilna ventilacija putem klima komore (KK2) s

povratom topline (rekuperatorska jedinica),. Rekuperatorska - ventilacijska jedinica kompaktnemonoblock izvedbe,

opremljena je sa visokoučinskim pločastim rekuperatorom (temperaturna učinkovitost 89%), tlačnim i odsisnim elektronički

upravljanim ventilatorima, filterima klase M5 i prigušivačima na tlačnom i odsisnom kanalu, te svim potrebnim elementima

za zaštitu, kontrolu i regulaciju uređaja.

Klima komora je smještena na ravnom dijelu krova prema postojećem dijelu građevine. Prilikom postavljanja jedinice

potrebno se pridržavati minimalnih potrebnih servisnih udaljenoisti od bočnih zidova, te minimalne potrebne visine ugradnje.

Zrak se od komore do usisnih i odsisnih mjesta distribuira putem limenih pocinčanih kanala, odgovarajućih dimenzija,

vođenih u spuštenom stropu. Kanali svježeg i otpadnog zraka izoliraju se paronepropusom izolacijom od kamene vune tipa

Larock, kao proizvod Rockwool, debljine prema specifikaciji. …

4.2.3. VENTILACIJA SANITARIJA

Ventilacija sanitarija predviđena je putem nadžbuknih ventilatora tipa ER-100-VZ količine odsisa 100 m3/h, kao proizvod MAICO.

Ventilatori imaju ugrađeni timer koji odgađa početak rada nakon paljenja putem strujne sklopke i odgađa prestanak rada

ventilatora za 6 min nakon gašenja putem sklopke. Ventilatori se priključuju na zajednički ventilacijskikanal, a otpadni zrak

izbacuje se u okolinu preko krova građevine. … Odsisani zrak iz prostorija nadomješta se zrakom iz susjednih prostorija preko

prestrujnih rešetki, odnosno zazora ispod vrata (usaglasiti sa dobavljačem unutarnje stolarije i arhitektom).

Projektant :

Darko Bailo, dipl.ing.stroj.

Svi prostori u zgradi grijati će se na prosječnu temperaturu od +20 °C, sistemom centralnog grijanja prostora preko

dizalice topline (COP=3,91) i plinskih bojlera. Sistem grijanja prostora je putem ventilokonvektora, radijatora i

podnog grijanja, te ventilacionih komora s rekuperacijom, sve prema strojarskom projektu. Tako se ne postavljaju

posebni zahtjevi za toplinsko izolacionu vrijednost pregrada između grijanih prostorija istog korisnika.

Priprema medija za hlađenje (i grijanje) prostora u zgradi se radi u dizalicama topline (EER=5,05), čije vanjska

jedinice su smještene u prizemlju u prostoriji spremišta sa jugozapadne strane dogradnje zgrade. Vanjske jedinice

klima komora kojima se vrši ventilacija podrumskih prostorija za edukaciju i ventilacije dvorane su smještene na

razini ravnog krova iznad prvog kata dogradnje zgrade sa zapadne strane zgrade. Za hlađenje zgrade preko ljetnih

mjeseci, proračuni su rađeni prema Algoritmu (MGIPU, Zagreb, svibanj 2017.) na prosječnu temperaturu od +22 °C.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 8

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

U zgradi koja je predmet ovog projekta postoji negrijani prostor spremišta u prizemlju zgrade (jugozapadni ugao) gdje

su smještene vanjske jedinice dizalice topline. Prostorije u grijanom dijelu zgrade bez zasebnih grijaćih tijela su

posredno grijane prostorije. Zgrada je toplinski izolirana prema svim vanjskim i negrijanim prostorima sve u skladu

sa Algoritmom (MGIPU, Zagreb, svibanj 2017.).

Svi boravišni prostori u građevini imaju mogućnost prirodnog ventiliranja (mogućnost otvaranja prozora) i prirodnog

osvjetljenja. Oni prostori koji nemaju prozora su umjetno ventilirani (mehanička ventilacija sa sanitarnim

ventilatorima) putem ventilacionog kanala preko krova građevine. Prostorije za edukaciju i višenamjenska učionica u

prizemlju te dvorana na katu imaju predviđeno mehaničko provjetravanje s izmjenjivačem topline (sustav za povrat

topline – rekuperacija sa cca 89%).

Potrošna topla voda (PTV) se dobiva navedenim plinskim bojlerima za vanjsku ugradnju koji služe i za grijanje zgrade.

Grijanje građevine riješit će se centralnim sustavom grijanja preko sustava s dizalicom topline na krovu zgrade, s

podstropnim razvodom cijevi u spuštenim stropovima ili podnim razvodom cijevi iznad ploča elastificiranog

polistirena u podnoj oblozi ili s oblogom cijevi pjenastom elastičnom trakom (dovod i odvod sistema grijanja). Cijevi

koje prolaze spuštenim stropovima moraju imati prigušivače buke da se buka koja se proizvodi u sustavu grijanja i

ventilacije ne širi u boravišne zone zgrade. U ovakvoj izvedbi grijanje neće predstavljati kritičan izvor buke i vibracija.

Iz razloga zvučne izolacije, projektirana debljina zida se ne smije tanjiti (prilikom montiranja instalacija), te je iz

razloga provođenja instalacija potrebno izvoditi dodatni parapetni zid (u prostorijama sanitarija).

U građevini nije predviđena izvedba pogonskih prostora koji mogu predstavljati kritične izvore buke, a koji se nalaze

uz boravišne prostore. Sve tehničke prostorije sa strojarskim postrojenjima su grupirane i smještene na izdvojenim

pozicijama u zgradi (jugozapadni dio zgrade u prizemlju uz pomoćne prostorije i na krovu zgrade). U građevini nema

dizala.

Instalacije unutar građevine ponavljaju se po vertikali na istom mjestu. Sanitarni čvorovi unutar građevine su

grupirani, te buka iz prostora sanitarija neće narušavati ostale prostorije.

Razvod svih glavnih vodova je riješen u instalacionim vertikalama koje su obložene lakim pregradnim stijenama kao

tipa Knauf. U sanitarijama u podnožju nekih zidova prema susjednim prostorijama (s drugačijim korištenjem,

boravišne prostorije i sl.) se predviđa izvođenje parapetnog zida u kojem se predviđa vođenje velikih instalacija

(kanalizacija i sl.).

Ukoliko se interijerski razmjesti predviđena postava sanitarija, potrebno je predvidjeti izvođenje parapetnog zida u

kojem se predviđa vođenje velikih instalacija (kanalizacija i sl.) kod pregradnih zidova sanitarija prema susjednim

boravišnim prostorijama (višenamjenska učionica, višenamjenska prostorija za edukaciju, kabinet, dvorana i sl.).

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 9

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

4. Zahtjevi:

Zahtjevi minimalne vrijednosti zvučne izolacije i maksimalne vrijednosti nivoa zvuka udara (prema HRN U.J6.201,

tabela 1/F):

RW, min (dB) LW, max (dB)

F.1 Zid bez vrata između učionica (višenamjenska učionica,

višenamjenska prostorija za edukaciju) 52 -

F.1 Zid bez vrata između učionice i kabineta (višenamjenska učionica /

kabinet) 52 -

F.3 Zid s vratima između učionice ili kabineta i hodnika (Dw,min) 37 -

F.4 Zid prema bučnoj pogonskoj prostoriji 57 -

F.6 Međukatna konstrukcija između učionice ili kabineta i dvorane 60 63

F.7 Međukatna konstrukcija prema donjoj bučnoj prostoriji 57 68

F.10 Međukatna konstrukcija 52 63

Interakcije unutar prostorne dispozicije:

Prostorije Kabinet 1 – spremište medicinske opreme i Kabinet 2 – spremište medicinske opreme su u služnosti dvorane

i zapravo su njen sastavni dio. Iz tog razloga se ta dva prostora ne promatraju bez međusobne interakcije kako u

funkcionalnom smislu, tako i u pogledu zvučne izolacije.

Obzirom na tip građevine (dogradnja dvorane u sklopu škole za medicinske sestre) ona neće biti uzrokom narušavanja

mira u okolišu. Dogradnja zgrade se nalazi u sklopu postojećeg školskog kompleksa, u centru grada Zagreba.

Najviše dopuštene ocjenske razine buke imisije u otvorenom prostoru prema HRN U.J6.201/89 i Pravilniku o najvišim

dozvoljenim razinama buke u sredini u kojima ljudi rade i borave NN 145/04 dane u tablici 1 su LRAeq = 50 dB(A)

noću i LRAeq = 65 dB(A) danju, za zonu mješovite, pretežito poslovne namjene sa stanovanjem.

Dopuštena razina buke s obzirom na vrstu djelatnosti:

- manje zahtjevni uredski poslovi, pretežno rutinski umni rad koji zahtjeva usredotočenje ili neposredno govorno i/ili

telefonsko komuniciranje, komunikacijske centrale (kabinet i sl.)

Leq = 60 dB(A) - (a) razina buke na radnom mjestu koja potječe od proizvodnih izvora odnosno

Leq = 50 dB(A) - (a) razina buke na radnom mjestu koja potječe od neproizvodnih izvora.

Prema članku 11. Pravilnika o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i borave (NN

145/2004) najviše dopuštene ekvivalentne razine buke u zatvorenim prostorijama posebne namjene za izložbene

prostorije, predavaonice i slične prostorije su 35 dB(A) – višenamjenska učionica, višenamjenska prostorija za

edukaciju, dvorana.

Sastav svih obodnih i pregradnih konstrukcija interesantnih za proračune zvučne zaštite naveden je u

Proračunu racionalne uporabe energije i toplinske zaštite (MAPA 2 dio a).

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 10

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

b) IZVEDBA

1. Podna konstrukcija – plivajući pod:

Međukatna konstrukcija je puna armiranobetonska stropna ploča debljine 22 cm - pregrada dostatne mase, a svi podovi

predviđeni su u izvedbi kao "plivajući".

Plivajući pod:

Zahtjevi za plivajuću podnu konstrukciju:

Slojevi plivajuće podne konstrukcije trebaju se izvesti materijalima određenih mehaničko – fizikalnih svojstava, a

konstrukcija u cjelini u uvjetima određene tehnološke kvalitete.

a) Površina armiranobetonske ploče: ukoliko je potrebno (jako neravna gornja ploha armiranobetonske stropne

ploče) treba izvesti izravnanje grubo izvedene konstrukcije stropne ploče kako bi se izbjeglo nastajanje zvučnih

mostova na mjestu neravnina. Izravnanje treba izvesti cementnim namazom M 20, debljine 1 – 2 cm ili nivelir

masom za izravnanje. Izravnanje cementnim namazom treba izvesti najkasnije 3 dana od izvedbe stropne ploče.

b) Mekoelastični sloj od elastificiranig ekspandiranog polistirena: dimenzija 50x100 cm u dva ili tri sloja debljine

po 1 cm (minimalno dva sloja). Elastificirani, ekspandirani polistiren treba biti gustoće 16 kg/m3, dinamičke

krutosti s' = 30 MN/m3, dimenzijski stabilan (odležan najmanje 3 mjeseca).

c) "Plivajući" namaz od armiranog (rabiciranog) mikrobetona: treba imati čvrstoću na tlak najmanje 30 N/mm2,

čvrstoću na savijanje 4 N/mm2, a tvrdoću (otpor na prodiranje) 60 N/mm2. Namaz se treba dobro zbiti, najveće

zrno agregata je 15 mm. Dobrim sastavom i pažljivom obradom svježeg betona treba se postići što manje

skupljanje namaza.

Obodno, namaz treba biti rubnim reškama odvojen od zidova. Rubne se reške izvode s elastificiranim

ekspandirani polistirenskim trakama min. debljine 1 cm, a rubni završeci poda uza zid trebaju se izvesti dilatirani

da se na tim spojevima spriječi nastajanje zvučnih mostova. Namaz se armira u sredini visine točkasto zavarenom

mrežom 5 mm s oknima maksimalno 10/10 cm. Moguće je armiranje "plivajućeg" namaza polipropilenskim

vlaknima.

Površina namaza obrađuje se izvedbom tzv. usječenih reški (najviše do pola visine namaza). Položaj usječenih

reški se određuje tako da odnos stranica nepodijeljenog polja bude cca 2:5, a najveća površina polja 4 m2.

Namaz se izvodi nakon postavljenog mekoelastičnog sloja i to na razdjelnu polietilensku foliju debljine 0,2 mm.

Preklapanje folija na mjestu spojeva iznosi 10 cm.

Gornja površina estriha mora biti vodoravna, završno obrađena i u potpunosti pripremljena za postavu podne

obloge

Također je potrebno sve završne podne slojeve također dilatirati od zidova i zidnih obloga.

Stubišni krakovi predviđaju se u izvedbi dilatirani od obodnih zidova, vezani samo na podeste.

Kod krovne konstrukcije s armiranobetonskom pločom kao podlogom za smještaj strojarskih postrojenja se kao sloj

za prigušenje topota primjenjuje se folija od ekstrudiranog polistirena, sa betonskom lagano armiranom podlogom

iznad. Ovako izvedene trake (tipa Dow Chemical Ethafoam 222-E u dva sloja (2x0,5 cm)), postižu razinu prigušenja

topota ΔLw = 25 dB.

Kao dodatna izolacija zračnog zvuka u međukatnim konstrukcijama dvorane prema prostorijama ispod se predviđa

postava mineralne vune debljine min.10 cm kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL ili

jednakovrijedan materijal u međuprostoru između nosivih profila konstrukcije i sa spuštenim stropom od

gipskartonskih ploča.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 11

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

2. Prodori instalacija kroz zidove i međukatne konstrukcije:

Prodori instalacija kroz pregrade između prostora trebaju se izvesti s omotačem od mineralne vune s potpunim

elastičnim brtvljenjem reški, s oslanjanjem na elastične nosače kako bi se spriječio prijenos strukturalnog zvuka i

vibracija na konstrukciju objekta. Eventualni uređaji i strojevi koji u svom radu stvaraju vibracije trebaju se izvesti

oslonjeni na podlogu preko elastičnih (gumenih) podložaka, koje treba isporučiti proizvođač dotične opreme, i koji će

onemogućiti u najvećoj mogućoj mjeri prijenos vibracija na nosivu konstrukciju građevine.

Kod pregradnih ili nosivih zidova između prostora, nije dozvoljeno smanjenje projektirane debljine zida prorezima za

vođenje instalacija (vodovod, kanalizacija i sl…). Sve potrebne instalacije treba voditi u dodatnom parapetnom obzidu

visine 90 cm (sanitarije), kako ne bi došlo do opadanja zvučnoizolacijskih karakteristika pregrade. Razvodne kutije

električnih instalacija i kutije za utičnice ne smiju se ugrađivati kod pregradnih ili nosivih zidova jedne nasuprot

drugoj, minimalni razmak između kutija mora iznositi 50 cm.

Predvidjeti u izvedbi tip "Baltik" zahodskih školjki, s horizontalnim spojem na kanalizacionu vertikalu, kako ne bi

došlo do prodora međukatnih konstrukcija, a time i nastanka zvučnih mostova između različitih prostora korisnika.

Razvod centralnog grijanja (dovod vode do grijaćeg tijela) predviđen je pod stropovima zgrade ili u plivajućim

podovima (ovisno o prostoru). Cijevi koje prolaze spuštenim stropovima moraju imati prigušivače buke da se buka

koja se proizvodi u sustavu grijanja, hlađenja i ventilacije ne širi u boravišne zone građevine. Cijevi koje prolaze

slojevima poda moraju biti omotane elastičnim slojem (filcom) (ako se vode u sloju elastificiranog polistirena) ili se

moraju voditi u cementnom estrihu (glazuri) iznad plivajućeg sloja (elastificiranog polistirena i polietilenske folije).

Zvučna izolacija od strukturalnog zvuka i vibracija

1. Za opremu i uređaje potrebno je predvidjeti antivibracijsko pričvršćenje opreme i druge mjere aktivne

akustičke zaštite na samim izvorima buke, što je predmet tehnološkog projekta.

2. Sva pričvršćenja opreme, cijevi i instalacijskih vodova na konstrukciji moraju biti izvedena elastičnim

ovjesom ili oslonjena na podmetače od gume ili plastike.

3. Svi prodori i cijevi koje prolaze kroz konstrukciju moraju biti izolirani mineralnom vunom, ili pustom, a na

vanjskim površinama obrađeni trajno elastičnim kitom, da se izbjegne kruta veza instalacija i konstrukcije.

4. Sve podove treba izvesti prema svim principima za "plivajuće" podove.

5. Svi instalacijski vodovi moraju biti i dodatno zvučno izolirani kamenom vunom, s indeksom kancerogenosti

Ki ≥ 40, mjereno prema TRGS 905.

6. Vertikalna okna za instalacije moraju biti obzidana punom opekom, prekinuta na etažnoj ploči,

zvukoizolirana mineralnom vunom, uz zrakotijesno brtvljenje i izoliranje svih proboja.

3. Pregradni zidovi i pregrade između različitih korisnika (vanjske konstrukcije)

Vanjski zidovi su predviđeni kao masivne pregrade – armiranobetonski zidovi debljine 20cm, 25cm i 30cm. S vanjske

strane zidovi su obloženi s toplinskom izolacijom fasadnim pločama od mineralne vune. Većina zidova je predviđena

kao ventilirano pročelje sa fasadnim pločama mineralne vune za ventilirano pročelje debljine 14cm u prizemlju i 16cm

na katu (ploče kao Knauf Insulation ploče za ventilirane fasade s crnim voalom NaturBoard Ventacusto GVB ili

NaturBoard Venti GVB ili jednakovrijedan materijal), sa završnom oblogom ventiliranog pročelja na podkonstrukciji

prema izboru projektanta, sve izvedeno prema preporukama proizvođača ventiliranog pročelja.

Vanjski zid zapadnog pročelja zgrade iznad razine prvog kata je armiranobetonski predviđen kao ETICS fasada, s

predviđenom toplinskom izolacijom od mineralne vune za ETICS fasade (kao Knauf Insulation ploče za kontaktne

fasade FKD S Thermal ili jednakovrijedan materijal) debljine 16 cm, sa završnom polimercementnom žbukom, kao

kompaktni fasadni sustav, sve izvedeno prema preporukama proizvođača za izvedbu žbuke na pločama mineralne

vune (ETICS fasada).

Kod podnožja vanjskih zidova izloženih prskanju kiše toplinska izolacija se izvodi s pločama ekstrudiranog polistirena

XPS minimalne, sa završnom polimercementnom žbukom ili sl., kao kompaktni fasadni sustav sokla iznad tla / terasa.

Krov iznad dvorane je laki ravni zeleni krov sa čeličnom konstrukcijom kao slagani krov, sa kompaktnim pločama od

tvrde mineralne vune debljine 25 cm položenom na trapezni profilirani lim.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 12

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Iznad nižeg dijela kata postoji ravni teški neprohodni krov sa teškom armiranobetonskom pločom debljine 16 cm kao

nosivim dijelom krova. Toplinska izolacija krova je predviđena pločama ekstrudiranog polistirena XPS debljine 30

cm položenim na armiranobetonsku ploču, te hidroizolacijom krova postavljenom iznad toplinske izolacije i parnom

branom ispod toplinske izolacije. Kao završna obloga krova je predviđen zaštitni sloj oblutaka.

Zid između grijanog i negrijanog dijela prizemlja koji je predviđen kao laka montažna pregradna stijena je od

gipskartonskih ploča kao tipa Knauf Diamant ploče na metalnoj podkonstrukciji (debljine 15 cm), s ispunom

međuprostora mineralnom vunom (kao Knauf Insulation filc za pregradne zidove TI 140 W, Knauf Insulation ECOSE

filc za pregradne zidove DECIBEL ili jednakovrijedni materijal debljine 10 cm), s obavezno postavljenom parnom

branom s toplije strane toplinske izolacije.

Unutarnji novi pregradni zidovi su predviđeni kao lake montažne pregradne stijene od gipskartonskih ploča na

metalnoj podkonstrukciji (debljine minimalno 10 cm), s ispunom međuprostora mineralnom vunom (kao Knauf

Insulation filc za pregradne zidove TI 140 W, Knauf Insulation ECOSE filc za pregradne zidove DECIBEL ili

jednakovrijedni materijal debljine 5 cm). Pregrade je potrebno izvoditi do nosive konstrukcije, iznad razine spuštenog

stropa (ukoliko on postoji kao interijerska završna obrada stropa).

Kod zidova gdje je potrebna bolja zvučna izolacija između različitih prostorija predviđena je upotreba gipskartonskih

ploča kao tipa Knauf Diamant ploče umjesto običnih gipskartonskih ploča (zidovi učionice, dvorane, prostorija za

edukaciju, kabineta i sl) debljine 15 cm ispunjenu mineralnom vunom debljine 10cm.

4. Prozori i vrata:

U odnosu na veličinu otvora na fasadi najviše izloženih vanjskoj buci u odnosu na masu punog zida, i intenzitet buke

prometa, vanjska buka nije kritična, te se pretpostavlja ugradnja jednostrukih prozora i ostakljenih stijena u

plastificiranim aluminijskim okvirima, s prekinutim toplinskim mostom i toplinski poboljšanim svojstvima.

Ostakljenje je sa dvostrukim termoizolacijskim staklom (IZO staklom) staklenih ploha debljine min. 4 mm, sa

zatvorenim zračnim međuslojem min. 12 mm i barem jednom neprekinutom brtvom na spoju krila i doprozornika.

Međurazmak je ispunjen plinom argonom.

Prema potrebi unutarnje staklo sigurnosno lamelirano – veće staklene površine i prema potrebi prostora.

Svi prozori imaju mogućnost otvaranja zbog prirodne ventilacije prostora.

Prozori i balkonska vrata su otklopno zaokretni ili klizni.

Zaštita od sunčevog zračenja:

Zaštita od sunčevog zračenja prozora u prizemlju je riješena unutarnjim žaluzinama bijele ili reflektirajuće površine i

male transparentnosti (ili sličnom zaštitom od sunca, rolo ili sl.), strehom i maksimalnim g = 0,60.

Zaštita od sunčevog zračenja istočnog i zapadnog pročelja dvorane za ergonomiju je riješena vanjskim brisolejima i

maksimalnim g = 0,60.

Zaštita od sunčevog zračenja prozora na dvorani za ergonomiju (sjeverno i južno pročelje) bez dodatne zaštite od

sunca je riješena s mutnim neprozirnim staklom s g = 0,60.

Zaštita od sunčevog zračenja ulaznih ostakljenih vrata (sjeverno i južno pročelje / prizemlje i kat) bez dodatne zaštite

od sunca je riješena sa staklom koje ima g = 0,33.

Navedeni prozori i staklene stijene predviđene u plastificiranim aluminijskim okvirima s prekinutim toplinskim

mostom i toplinski poboljšanim svojstvima, ostakljenje IZO staklom; dva sloja stakla 4+16+6 mm mogu postići

zvučno gušenje (prema laboratorijskim ispitivanjima) cca Rw= 33 dB.

Prozori koji prema certifikatu imaju Rw= 32 dB, kao ugrađeni postižu zvučno gušenje Rw= 31 dB.

Unutarnja vrata trebaju se izvesti slijedeće kvalitete:

Rw, min = 25 – 29 dB (2. klasa) za sanitarije i pomoćne prostorije

Rw. min = 30 – 32 dB (1. klasa) za sve ostale prostorije (kabinet).

Rw. min = ≥32 dB (1. klasa) za sve učionice / prostorije za edukaciju, dvoranu.

Spoj krila s dovratnikom treba biti brtvljen s minimalno jednom kontinuiranom gumenom trakom.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 13

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Izolacijsku vrijednost ugrađenih vrata i prozora treba dokazati laboratorijskim ispitivanjima, a kategorizaciju provesti

sa stručnom službom investitora, odnosno dokazati certifikatima proizvođača ugrađenih vrata i prozora (dokazima o

laboratorijskim ispitivanjima s zadovoljavajućim postignutim rezultatima).

Prozore, ostakljena vrata i staklene stijene obavezno izvoditi (ugrađivati) prema uputama i preporukama proizvođača.

Posebni uvjeti za prozirne konstrukcije:

1. Krila moraju čvrsto prilijegati na okvire.

2. Prozori moraju imati brtve u nasjednim utorima, dovoljne krutosti.

3. Svi zazori moraju biti dodatno neprekidno brtvljeni sa mekanom zaštitnom trakom, trajno elastičnom, otpornom

na starenje, koja se može lako čistiti, čemu je udovoljeno.

4. Prozori moraju biti osigurani s dovoljnim brojem učvrsnih zapora ("rigli") i šarki i tako konstruirani da se osigura

jednoličan pritisak, dovoljnog intenziteta na nalijegajućim plohama.

5. Prozorski okviri imaju minimalno dvostruke utore, što također zadovoljava citiranu normu, gdje se traži

najmanje 1 utor, odnosno nalijegajuća ploha.

6. Međuprostori između stakala ne smiju biti ventilirani.

7. Uložak za odmagljivanje međuprostora mora biti ugrađen na način da ne smanjuje zvučnu izolaciju.

8. Kakvoća stakala s obzirom na sigurnost od loma i mogućnosti izazivanja povreda (laminirano, kaljeno i

slično specijalno staklo) nije predmet ovog dijela projekta. Navedene debljine stakala određene su samo

kao akustički minimalne debljine, odnosno zadovoljavanje parametara u odnosnu na uštedu toplinske

energije i toplinsku zaštitu.

9. Za toplinske uvjete vidjeti projekt zgrade u odnosnu na uštedu toplinske energije i toplinsku zaštitu.

5. Akustička obrada prostora:

Rješenjem interijera treba riješiti akustičku obradu prostora radi vremena odjeka kod prostora u kojima je to potrebno

(učionica, prostorija za edukaciju, dvorana i sl.), a sve ovisno o interijerskoj postavi i koorištenim završnim

materijalima obloga zidova, stropova i podova kao interijerskim pomičnim oblogama (panoi, tepisi, zavjese i sl.).

Da bi se navedeni prostori zaštitili od prevelike buke i odjeka u njima potrebno je obložiti pojedine plohe akustik

oblogama (npr. perforirane ploče za upijanje zvuka na podgledu stropne konstrukcije i sl…) ili birati namještaj čiji

materijali imaju učinak upijanja zvuka. Odabir akustik obloge i razmještaj na površinama zida i stropova definirati će

se projektom interijera te projektom akustike (ukoliko postoji zahtjev za njim, postava razglasa ili sl.).

Kao akustička obloga predlažu se perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE

12/25 Q – ploče s akustičkim voalom (standardno crne boje) (koji zamjenjuje u smislu zvučne izolacije 5 cm mineralne

vune) + 5 cm mineralne vune (u podgledu stropa, odnosno obloge zida). Akustik ploče treba montirati na odmaku od

podloge (stropa) cca 200 mm, dok su ploče od zida odmaknute cca 50 mm ili više.

Sloj zraka između podloge i akustičke obloge je ventiliran unutarnjim zrakom kako bi se spriječila neželjena

kondenzacija. Perforirana površina gore navedenih ploča je cca 18,1 %.

Detaljni odabir akustik obloge i razmještaj na površinama zidova i stropova obavezno će se definirati projektom

interijera. Isto tako će se u projektu interijera za sve prostore u kojima je to potrebno definirat razmještaj materijala

za završne obloge zidova, stropova i podova, te odabir namještaja radi vremena odjeka.

Kod svakog interijerskog zahvata i promijene materijala obloga zidova, podova, stropova, postave namještaja i slične

promijene ulaznih podataka, izračuni se mijenjaju.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 14

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

6. Izvedba kritičnih konstrukcija građevine:

Da bi se širenje buke i vibracija iz tehničkih prostora građevine i buke ostalih tehničkih (strojarskih) uređaja svelo na

minimum, predviđene su slijedeće tehničke mjere:

- obodne konstrukcije izvesti će se kao pregrade koje imaju dostatnu zvučnu izolaciju,

- pod će se izvesti kao plivajući pod sa obavezno izvedenom rubnom trakom koja odvaja slojeve poda od obodnih

zidova,

- uređaji se sidre u plivajuću podnu podlogu koju treba dimenzionirati ovisno o težini uređaja i statičkom proračunu,

ali ne manje od pretpostavljene debljine,

- uređaji koji u svom radu stvaraju vibracije oslonit će se na podlogu preko odgovarajućih vibroizolatora, koje je

dužan isporučiti proizvođač dotične opreme,

- sva instalacija razvoda biti će ugrađena s fleksibilnim ovjesima kojima se prigušuju eventualno nastale vibracije,

- sva pričvršćenja ostalih elemenata koji su povezani sa izvorom buke i vibracija povezuju se za konstrukciju objekta

isključivo preko elastičnih veza,

- kanali/otvori za usis i ispuh zraka na vanjskom oplošju građevine ne smiju imati nivo buke na rešetki više od 65

dB(A) mjereno na udaljenosti 1 metar od elementa. Ukoliko se prema strojarskim proračunima utvrdi da pad razine

buke neće biti u predviđenim veličinama obavezna je ugradnja zvuko-apsorbirajućih elemenata ili konstrukcija koji

će smanjiti nivo buke ispod dozvoljene granice. Ove elemente obraditi u ostaloj tehničkoj dokumentaciji.

- za izvedbu vanjskih usisnih i ispušnih elemenata treba primijeniti odgovarajuće prigušivače zvuka kako bi se nivo

buke u okolini građevine zadržao u pretpostavljenim veličinama.

Nivo buke na vanjskim elementima za usis i ispuh zraka ne smije preći nivo pretpostavljene buke na udaljenosti 1

metar od elementa koji iznosi ukupno max 65 dB(A). U tu svrhu potrebno je u strojarskim proračunima dokazati

pretpostavljenu veličinu, te prema potrebi ugraditi prigušivače buke.

Nakon izvedbe građevine ukoliko se za to ukaže potreba (ukoliko su izabrani i ugrađeni strojarski uređaji bučniji od

parametara pretpostavljenih ovim proračunima i sl.) ispitivanjem na terenu utvrditi pretpostavljene veličine. U slučaju

rezultata nepovoljnijih od predviđenih poduzeti dodatne mjere kako bi se buka uređaja i elemenata, te njen utjecaj na

okolne zahtjevne prostore sveo u dozvoljene granice.

Detaljan nacrt tehničkih prostora i načini ugradnje strojarskih uređaja i elemenata sastavni su dio strojarske tehničke

dokumentacije. Prilikom izvedbe treba tražiti od proizvođača razrađeni projekt i konstrukcijske detalje u smislu

postavljene koncepcije rješenja.

7. Program kontrole i osiguranja kvalitete:

Program kontrole i osiguranja kvalitete izrađen na temelju Zakona o gradnji (NN 153/2013, 020/2017, 039/2019,

125/2019).

Prema zahtjevima nadzornog inženjera potrebno je mjerenjem dokazati da nivo buke u prostorijama najbližim javnim

prometnicama ne prelazi dozvoljeni nivo. Prema zahtjevima nadzornog inženjera potrebno je provjeriti akustička

svojstva ugrađenih materijala radi zadovoljavanja konstrukcija na zvuk udara. Prema zahtjevima nadzornog inženjera

prije naknadne ugradnje bilo kojeg bučnog uređaja izvan građevine potrebno je provjeriti da buka od uređaja ispred

najbliže susjedne građevine odnosno međe parcele ne prelazi 50 dB(A) u noćnom radu i 65 dB(A) po danu, prema

zahtjevima iz Pravilnika o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i borave NN 145/04.

Prema zahtjevima nadzornog inženjera prije naknadne ugradnje bilo kojeg bučnog uređaja u građevinu potrebno je

provjeriti da buka u obrazovnim prostorijama (učionica, prostorija za edukaciju, dvorana) ne prelazi najviše dozvoljeni

nivo buke od 35 dB(A), prema zahtjevima iz Pravilnika o najvišim dozvoljenim razinama buke u sredini u kojima

ljudi rade i borave NN 145/04.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 15

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

c) RAČUNSKE PRETPOSTAVKE

1. Zid bez vrata između učionica (višenamjenska učionica, višenamjenska prostorija za edukaciju) :

Laka pregradna stijena s poboljšanim zvučnim karakteristikama d=15,0cm (između dvije višenamjenske prostorije za

edukaciju i prema drugom prostorijama, laki zid dvorane prema drugim prostorijama, zidovi kabineta), laka pregradna

stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm; kao Knauf pregradni zid

W112 Diamant pregradni zid; jednostruka podkonstrukcija + dvoslojna obloga Diamant pločama (konstrukcija oznake

UZ4)

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima -

kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili jednakovrijedan materijal

ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne

obloge je 10 cm

10 cm

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

Potkonstrukcija je od čeličnih MW ili CW profila širine 10 cm i obostrano se oblaže dvostrukom oblogom od

gipskartonskih ploča tipa Diamant (protupožarna izolacija, poboljšana zvučna izolacija, vlagootpornost) d= 1,25 cm

gustoće cca 1024 kg/m3. U međuprostor se postavlja 10 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN

13162.

Gipskartonske ploče se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama.

Na tako postavljene gipskartonske ploče, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene

keramičke pločice (prostori sanitarija i sl.).

ZVUČNA IZOLACIJA stijene W112 - Diamant pregradni zid debljine 15,0 cm JE 63 dB (A) – prema specifikacijama

proizvođača. Preporuka je da se Knauf ploče spajaju klamanjem, a ne vijcima, jer se dobije još bolja zvučna izolacija

izvedenih zidova.

Laka pregrada kao tipa "Knauf W112 Diamant pregradni zid" debljine 15,0 cm, koja se sastoji od jedne metalne

potkonstrukcije širine 10,0 cm koja je sa obje strane obložena dvjema gipskartonskim pločama tipa Diamant, a

međuprostor je ispunjen sa 10,0 cm mineralne vune. Ukupna širina takve pregrade iznosi 15,0 cm.

Prema katalogu proizvođača takva pregrada ima vrijednost zvučne izolacije RW = 63 dB. Kod ugradnje u obodne

pregrade zbog bočnog prijenosa zvuka (posredni putevi prijenosa zvuka), vrijednost zvučne izolacije takve pregrade

se umanjuje za cca 5 dB i ona u tom slučaju postiže zvučnu izolaciju od Rw = RW – 5 dB,

što iznosi: Rw = 63 - 5 dB = 58 dB.

Rw= 58 dB > Rw,min= 52 dB

Rw,min= 52 dB za zidove između promatranih prostora, te konstrukcija zadovoljava u pogledu propisane vrijednosti

zvučne izolacije zračnog zvuka.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 16

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

2. Zid bez vrata između učionice i kabineta (višenamjenska učionica / kabinet) :

Laka pregradna stijena s poboljšanim zvučnim karakteristikama d=15,0cm (između dvije višenamjenske prostorije za

edukaciju i prema drugom prostorijama, laki zid dvorane prema drugim prostorijama, zidovi kabineta), laka pregradna

stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm; kao Knauf pregradni zid

W112 Diamant pregradni zid; jednostruka podkonstrukcija + dvoslojna obloga Diamant pločama (konstrukcija oznake

UZ4)

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima -

kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili jednakovrijedan materijal

ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne

obloge je 10 cm

10 cm

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

Potkonstrukcija je od čeličnih MW ili CW profila širine 10 cm i obostrano se oblaže dvostrukom oblogom od

gipskartonskih ploča tipa Diamant (protupožarna izolacija, poboljšana zvučna izolacija, vlagootpornost) d= 1,25 cm

gustoće cca 1024 kg/m3. U međuprostor se postavlja 10 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN

13162.

Gipskartonske ploče se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama.

Na tako postavljene gipskartonske ploče, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene

keramičke pločice (prostori sanitarija i sl.).

ZVUČNA IZOLACIJA stijene W112 - Diamant pregradni zid debljine 15,0 cm JE 63 dB (A) – prema specifikacijama

proizvođača. Preporuka je da se Knauf ploče spajaju klamanjem, a ne vijcima, jer se dobije još bolja zvučna izolacija

izvedenih zidova.

Laka pregrada kao tipa "Knauf W112 Diamant pregradni zid" debljine 15,0 cm, koja se sastoji od jedne metalne

potkonstrukcije širine 10,0 cm koja je sa obje strane obložena dvjema gipskartonskim pločama tipa Diamant, a

međuprostor je ispunjen sa 10,0 cm mineralne vune. Ukupna širina takve pregrade iznosi 15,0 cm.

Prema katalogu proizvođača takva pregrada ima vrijednost zvučne izolacije RW = 63 dB. Kod ugradnje u obodne

pregrade zbog bočnog prijenosa zvuka (posredni putevi prijenosa zvuka), vrijednost zvučne izolacije takve pregrade

se umanjuje za cca 5 dB i ona u tom slučaju postiže zvučnu izolaciju od Rw = RW – 5 dB,

što iznosi: Rw = 63 - 5 dB = 58 dB.

Rw= 58 dB > Rw,min= 52 dB

Rw,min= 52 dB za zidove između promatranih prostora, te konstrukcija zadovoljava u pogledu propisane vrijednosti

zvučne izolacije zračnog zvuka.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 17

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

3. Zid s vratima između učionice ili kabineta i hodnika (Dw,min) :

Laka pregradna stijena s poboljšanim zvučnim karakteristikama d=15,0cm (između dvije višenamjenske prostorije za

edukaciju i prema drugom prostorijama, laki zid dvorane prema drugim prostorijama, zidovi kabineta), laka pregradna

stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm; kao Knauf pregradni zid

W112 Diamant pregradni zid; jednostruka podkonstrukcija + dvoslojna obloga Diamant pločama (konstrukcija oznake

UZ4)

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima -

kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili jednakovrijedan materijal

ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne

obloge je 10 cm

10 cm

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

Potkonstrukcija je od čeličnih MW ili CW profila širine 10 cm i obostrano se oblaže dvostrukom oblogom od

gipskartonskih ploča tipa Diamant (protupožarna izolacija, poboljšana zvučna izolacija, vlagootpornost) d= 1,25 cm

gustoće cca 1024 kg/m3. U međuprostor se postavlja 10 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN

13162.

Gipskartonske ploče se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama.

Na tako postavljene gipskartonske ploče, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene

keramičke pločice (prostori sanitarija i sl.).

ZVUČNA IZOLACIJA stijene W112 - Diamant pregradni zid debljine 15,0 cm JE 63 dB (A) – prema specifikacijama

proizvođača. Preporuka je da se Knauf ploče spajaju klamanjem, a ne vijcima, jer se dobije još bolja zvučna izolacija

izvedenih zidova.

Laka pregrada kao tipa "Knauf W112 Diamant pregradni zid" debljine 15,0 cm, koja se sastoji od jedne metalne

potkonstrukcije širine 10,0 cm koja je sa obje strane obložena dvjema gipskartonskim pločama tipa Diamant, a

međuprostor je ispunjen sa 10,0 cm mineralne vune. Ukupna širina takve pregrade iznosi 15,0 cm.

Prema katalogu proizvođača takva pregrada ima vrijednost zvučne izolacije RW = 63 dB. Kod ugradnje u obodne

pregrade zbog bočnog prijenosa zvuka (posredni putevi prijenosa zvuka), vrijednost zvučne izolacije takve pregrade

se umanjuje za cca 5 dB i ona u tom slučaju postiže zvučnu izolaciju od Rw = RW – 5 dB,

što iznosi: Rw = 63 - 5 dB = 58 dB.

Kako pregradna stijena između učionice ili kabineta i hodnika ima vrata potrebno je izračunati da li takav zid sa

vratima zadovoljava predviđene kriterije zvučne izolacije.

Vrata koja su između učionice, prostorije za edukaciju i hodnika imaju Rw, min = 32 dB.

Rzida= 58 dB; Rvrata= 32 dB;

Azida= 2,89 m²; Avrata= 2,10 m²;

Prema izrazu iz DIN 4109:

R w,srednji = -10 * log ( 2,10 * 10 -3,2 + 2,89 * 10 -5,8 ) / 4,99

R w,srednji = 35,7 dB

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 18

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Pa prema izrazu:

Dw,srednje (zid s vratima) = Rw,srednji - 10 log Sg/A + 16 log d - 3

Sg = ukupna vanjska površina zida kod ulaznih vrata: Sg = 4,99 m2

A = ekvivalentna apsorpcijska površina, približno: površina poda prostorije x 0,8 :

A = 32,24 x 0,8 = 25,79 m2

d = udaljenost od izvora buke do boravišne prostorije; d = 6,75 m

D w,srednje = 35,7 - 10 log 4,99 / 25,79 + 16 log 6,75 - 3

D w,srednje = 53,1 dB

Dw,srednje (zida s vratima) > Dw,min

53,1 > 37 dB

zadovoljava

Dw,min= 37 dB za zidove između promatranih prostora, te konstrukcija zadovoljava u pogledu propisane vrijednosti

zvučne izolacije zračnog zvuka.

4. Zid prema bučnoj pogonskoj prostoriji :

a) armiranobetonski zid debljine 30cm s ETICS fasadom (konstrukcija oznake UZ2)

produžna žbuka 1800 kg/m3 2 cm 36 kg/m2

armirani beton 2300 kg/m3 30 cm 690 kg/m2

mineralna vuna 115 kg/m3 10 cm 12 kg/m2

polimercementno ljepilo 1800 kg/m3 0,3 cm 5,4 kg/m2

završna žbuka 1800 kg/m3 0,2 cm 3,6 kg/m2

M .= 747 kg/m2

promatrano kao jednostruka konstrukcija, površinska težina obodnih pregrada > 300 kg/m2;

prema DIN 4109, Beiblatt 1, tab. 1: Rw > 59 dB

Uz izvedbu naknadne postave ploča obloge, bez krute veze sa podlogom, neće doći do opadanja prosječne

zvučnoizolacijske moći pregrade, a kod izvedbe obloge pločama sa mineralnom vunom, može se očekivati poboljšanje

prosječne zvučnoizolacijske vrijednosti pregrade od najmanje 5 dB.

Doprinos ploča mineralne vune

Rw > 59 dB + 5 dB > 64 dB

Rw= 64 dB > Rw,min= 57 dB

Rw,min= 57 dB za zidove između promatranih prostora, te konstrukcija zadovoljava u pogledu propisane vrijednosti

zvučne izolacije zračnog zvuka.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 19

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

b) Laka pregradna stijena između grijanog i negrijanog prostora d=15,0cm (prema spremištu u prizemlju), laka

pregradna stijena od gipskartonskih ploča tipa Diamant na metalnoj potkonstrukciji - debljine 15,0 cm; kao

Knauf pregradni zid W112 Diamant pregradni zid; jednostruka podkonstrukcija + dvoslojna obloga Diamant

pločama (konstrukcija oznake UZ3)

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

- parna brana – kao Sarnavap 1000 E (polietilenska parna brana, obavezno sa ljepljenjem

preklopa i uz rubna ljepljenja) ili Knauf Insulation HOMESEAL LDS 100 AluPlus parna brana

(90 g/m2) ili jednakovrijedan materijal, postava parne brane u svemu prema uputama

proizvođača (moguće ih je zabrtviti i ljepljivim trakama kao Soliplan i Solifit) (Klasa gorivosti

po HRN EN 13501-1: E)

0,02 cm

- mineralna vuna između hladno oblikovanih profila potkonstrukcije nosača od čeličnog lima -

kao Knauf Insulation ECOSE filc za pregradne zidove TI 140W - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,037 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili kao Knauf Insulation ECOSE filc za pregradne zidove DECIBEL - deklarirana toplinska

provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa gorivosti po HRN EN 13501-1: A1

ili jednakovrijedan materijal

ispuna elastične potkonstrukcije limenih CW ili MW profila; međurazmak između ploča zidne

obloge je 10 cm

10 cm

- tvrda protupožarna impregnirana gipskartonska ploča tipa kao Knauf Diamant ploča (1024

kg/m3) ili jednakovrijedan materijal, 2 x 12,5 mm (Klasa gorivosti po HRN EN 13501-1: A2-s1,

d0); na potkonstrukciji

2,5 cm

Potkonstrukcija je od čeličnih MW ili CW profila širine 10 cm i obostrano se oblaže dvostrukom oblogom od

gipskartonskih ploča tipa Diamant (protupožarna izolacija, poboljšana zvučna izolacija, vlagootpornost) d= 1,25 cm

gustoće cca 1024 kg/m3. U međuprostor se postavlja 10 cm mineralne vune gustoće 15-30 kg/m3 prema HRN EN

13162.

Gipskartonske ploče se gletaju i bojaju disperzivnim ili silikatnim (perivim) bojama.

Na tako postavljene gipskartonske ploče, ovisno o prostoru u kojem se nalazi, prema potrebi se postavljaju lijepljene

keramičke pločice (prostori sanitarija i sl.).

ZVUČNA IZOLACIJA stijene W112 - Diamant pregradni zid debljine 15,0 cm JE 63 dB (A) – prema specifikacijama

proizvođača. Preporuka je da se Knauf ploče spajaju klamanjem, a ne vijcima, jer se dobije još bolja zvučna izolacija

izvedenih zidova.

Laka pregrada kao tipa "Knauf W112 Diamant pregradni zid" debljine 15,0 cm, koja se sastoji od jedne metalne

potkonstrukcije širine 10,0 cm koja je sa obje strane obložena dvjema gipskartonskim pločama tipa Diamant, a

međuprostor je ispunjen sa 10,0 cm mineralne vune. Ukupna širina takve pregrade iznosi 15,0 cm.

Prema katalogu proizvođača takva pregrada ima vrijednost zvučne izolacije RW = 63 dB. Kod ugradnje u obodne

pregrade zbog bočnog prijenosa zvuka (posredni putevi prijenosa zvuka), vrijednost zvučne izolacije takve pregrade

se umanjuje za cca 5 dB i ona u tom slučaju postiže zvučnu izolaciju od Rw = RW – 5 dB,

što iznosi: Rw = 63 - 5 dB = 58 dB.

Rw= 58 dB > Rw,min= 57 dB

Rw,min= 57 dB za zidove između promatranih prostora, te konstrukcija zadovoljava u pogledu propisane vrijednosti

zvučne izolacije zračnog zvuka.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 20

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

5. Međukatna konstrukcija između učionice ili kabineta i dvorane :

puna armiranobetonska stropna pločom debljine 22 cm + spušteni strop s mineralnom vunom (konstrukcija oznake

M1):

sportski pod .- kg/m3 5 - 7 cm .- kg/m2

plivajući cementni estrih 2200 kg/m3 4 cm 88 kg/m2

PE folija 1000 kg/m3 0,02 cm 0,2 kg/m2

ekspandirani polistiren EPS 150 25 kg/m3 1 cm 0,25 kg/m2

elastificirani polistiren EPS-T 15 kg/m3 2 cm 0,3 kg/m2

armiranobetonska ploča 2300 kg/m3 22 cm 506 kg/m2

neventilirani zrak+potkonstrukcija + MW 15 kg/m3 5 cm 1 kg/m2

gipskartonske ploče 700 kg/m3 1,25 cm 8,75 kg/m2

M .= 604,25 kg/m2

M-1 .= 88 kg/m2

M-2 .= 506 kg/m2

prema DIN 4109, Beiblatt 1, tab. 12, stropna ploča površinske težine M = 506 kg/m2, s plivajućom podnom oblogom

i mineralnom vunom u podgledu stropa (spušteni strop)

Rw = 62 dB

površinska težina obodnih pregrada u suterenu > 350 kg/m2, pa prema DIN 4109, Beiblatt 1, tab. 13

Rw = 62 dB + 1 dB = 63 dB

Rw= 63 dB > Rw,min= 60 dB

Rw,min= 60 dB za međukatnu konstrukciju između navedenih prostora, te konstrukcija zadovoljava u pogledu

propisane vrijednosti zvučne izolacije zračnog zvuka.

Izolacija od udarnog zvuka:

kritična frekvencija:

Edin = 0,6 MN/m2 a = 0,02 m fo = 160 √30/88 = 93,42 < 100 Hz

Iu,ploče = 35 log 506 - 101 = - 6,4 dB

L500 = 40 log 500/fo = 40 log 500/93,42 = 29,1 dB

Iu,ukupno = I u,ploče + L500 - 2 dB – 5 dB = - 6,4 dB + 29,1 dB – 2 dB – 5 dB = 15,7 dB

Lw = 68 – 15,7 = 52,3 dB < 63 dB

Razina zvuka udara za promatranu konstrukciju je manja od najveće dozvoljene vrijednosti koja iznosi Lw,max= 63 dB,

pa se može ocijeniti da projektirana stropna konstrukcija zadovoljava i u pogledu zvučne izolacije udarnog zvuka.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 21

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

6. Međukatna konstrukcija prema donjoj bučnoj prostoriji :

puna armiranobetonska stropna pločom debljine 22 cm + ETICS fasada (konstrukcija oznake M6):

plivajući cementni estrih 2200 kg/m3 4 cm 88 kg/m2

PE folija 1000 kg/m3 0,02 cm 0,2 kg/m2

ekspandirani polistiren EPS 150 25 kg/m3 5 cm 1,25 kg/m2

elastificirani polistiren EPS-T 15 kg/m3 2 cm 0,3 kg/m2

armiranobetonska ploča 2300 kg/m3 22 cm 506 kg/m2

mineralna vuna 115 kg/m3 5 cm 6 kg/m2

polimercementno ljepilo 1800 kg/m3 0,3 cm 5,4 kg/m2

završna žbuka 1800 kg/m3 0,2 cm 3,6 kg/m2

M .= 610,5 kg/m2

M-1 .= 88 kg/m2

M-2 .= 506 kg/m2

prema DIN 4109, Beiblatt 1, tab. 12, stropna ploča površinske težine M = 506 kg/m2, s plivajućom podnom oblogom

Rw = 59 dB

površinska težina obodnih pregrada u suterenu > 350 kg/m2, pa prema DIN 4109, Beiblatt 1, tab. 13

Rw = 59 dB + 1 dB = 60 dB

Uz izvedbu naknadne postave ploča obloge, bez krute veze sa podlogom, neće doći do opadanja prosječne

zvučnoizolacijske moći pregrade, a kod izvedbe obloge pločama sa mineralnom vunom, može se očekivati poboljšanje

prosječne zvučnoizolacijske vrijednosti pregrade od najmanje 5 dB.

Doprinos ploča mineralne vune

Rw = 60 dB + 5 dB = 65 dB

Rw= 65 dB > Rw,min= 57 dB

Rw,min= 57 dB za međukatnu konstrukciju između navedenih prostora, te konstrukcija zadovoljava u pogledu

propisane vrijednosti zvučne izolacije zračnog zvuka.

Izolacija od udarnog zvuka:

kritična frekvencija:

Edin = 0,6 MN/m2 a = 0,02 m fo = 160 √30/88 = 93,42 < 100 Hz

Iu,ploče = 35 log 506 - 101 = - 6,4 dB

L500 = 40 log 500/fo = 40 log 500/93,42 = 29,1 dB

Iu,ukupno = I u,ploče + L500 - 2 dB – 5 dB = - 6,4 dB + 29,1 dB – 2 dB – 5 dB = 15,7 dB

Lw = 68 – 15,7 = 52,3 dB < 68 dB

Razina zvuka udara za promatranu konstrukciju je manja od najveće dozvoljene vrijednosti koja iznosi Lw,max= 68 dB,

pa se može ocijeniti da projektirana stropna konstrukcija zadovoljava i u pogledu zvučne izolacije udarnog zvuka.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 22

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

7. Međukatna konstrukcija:

puna armiranobetonska stropna pločom debljine 22 cm (konstrukcije oznaka M3, M4):

- međukatna konstrukcija i međukatna konstrukcija u sanitarijama su jednake osim što u sanitarijama postoji još

pričuvna hidroizolacija

plivajući cementni estrih 2200 kg/m3 4 cm 88 kg/m2

PE folija 1000 kg/m3 0,02 cm 0,2 kg/m2

ekspandirani polistiren EPS 150 25 kg/m3 5 cm 1,25 kg/m2

elastificirani polistiren EPS-T 15 kg/m3 2 cm 0,3 kg/m2

armiranobetonska ploča 2300 kg/m3 22 cm 506 kg/m2

neventilirani zrak+potkonstrukcija 0 kg/m3 5 cm 0 kg/m2

gipskartonske ploče 700 kg/m3 1,25 cm 8,75 kg/m2

M .= 604,5 kg/m2

M-1 .= 88 kg/m2

M-2 .= 506 kg/m2

prema DIN 4109, Beiblatt 1, tab. 12, stropna ploča površinske težine M = 506 kg/m2, s plivajućom podnom oblogom

(i spuštenim stropom, ali bez dodatne zvučne zaštite korištenjem mineralnom vunom – ne uzima se u obzir)

Rw = 59 dB

površinska težina obodnih pregrada u suterenu > 350 kg/m2, pa prema DIN 4109, Beiblatt 1, tab. 13

Rw = 59 dB + 1 dB = 60 dB

Rw= 60 dB > Rw,min= 52 dB

Rw,min= 52 dB za međukatnu konstrukciju između navedenih prostora, te konstrukcija zadovoljava u pogledu

propisane vrijednosti zvučne izolacije zračnog zvuka.

Izolacija od udarnog zvuka:

kritična frekvencija:

Edin = 0,6 MN/m2 a = 0,02 m fo = 160 √30/88 = 93,42 < 100 Hz

Iu,ploče = 35 log 506 - 101 = - 6,4 dB

L500 = 40 log 500/fo = 40 log 500/93,42 = 29,1 dB

Iu,ukupno = I u,ploče + L500 - 2 dB – 5 dB = - 6,4 dB + 29,1 dB – 2 dB – 5 dB = 15,7 dB

Lw = 68 – 15,7 = 52,3 dB < 63 dB

Razina zvuka udara za promatranu konstrukciju je manja od najveće dozvoljene vrijednosti koja iznosi Lw,max= 63 dB,

pa se može ocijeniti da projektirana stropna konstrukcija zadovoljava i u pogledu zvučne izolacije udarnog zvuka.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 23

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

d) VANJSKE KONSTRUKCIJE

vanjski ventilirani zid od armiranog betona – debljine 25 cm (konstrukcija oznake Z1) :

produžna žbuka 1800 kg/m3 2 cm 36 kg/m2

armirani beton 2300 kg/m3 25 cm 575 kg/m2

mineralna vuna 50 kg/m3 14 cm 7 kg/m2

ventilirani sloj zraka .- kg/m3 4 cm .- kg/m2

obloga zida .- kg/m3 .- cm .- kg/m2

M .= 618 kg/m2

promatrano kao jednostruka konstrukcija, površinska težina obodnih pregrada > 300 kg/m2;

prema DIN 4109, Beiblatt 1, tab. 1: Rw > 56 dB

Uz izvedbu naknadne postave ploča obloge, bez krute veze sa podlogom, neće doći do opadanja prosječne

zvučnoizolacijske moći pregrade, a kod izvedbe obloge pločama sa mineralnom vunom, može se očekivati poboljšanje

prosječne zvučnoizolacijske vrijednosti pregrade od najmanje 5 dB.

Doprinos ploča mineralne vune

Rw > 56 dB + 5 dB > 61 dB

vanjski ventilirani zid od armiranog betona – debljine 30 cm (konstrukcija oznake Z2, Z2a) :

produžna žbuka 1800 kg/m3 2 cm 36 kg/m2

armirani beton 2300 kg/m3 30 cm 690 kg/m2

mineralna vuna 50 kg/m3 16 cm 8 kg/m2

ventilirani sloj zraka .- kg/m3 4 cm .- kg/m2

obloga zida .- kg/m3 .- cm .- kg/m2

M .= 734 kg/m2

promatrano kao jednostruka konstrukcija, površinska težina obodnih pregrada > 300 kg/m2;

prema DIN 4109, Beiblatt 1, tab. 1: Rw > 59 dB

Uz izvedbu naknadne postave ploča obloge, bez krute veze sa podlogom, neće doći do opadanja prosječne

zvučnoizolacijske moći pregrade, a kod izvedbe obloge pločama sa mineralnom vunom, može se očekivati poboljšanje

prosječne zvučnoizolacijske vrijednosti pregrade od najmanje 5 dB.

Doprinos ploča mineralne vune

Rw > 59 dB + 5 dB > 64 dB

vanjski armiranobetonski zid s ETICS fasadom – debljine 30 cm (za konstrukcije oznaka Z3) :

armirani beton 2300 kg/m3 30 cm 690 kg/m2

mineralna vuna 115 kg/m3 16 cm 18 kg/m2

polimercementno ljepilo 1800 kg/m3 0,3 cm 5,4 kg/m2

završna žbuka 1800 kg/m3 0,2 cm 3,6 kg/m2

M .= 717 kg/m2

promatrano kao jednostruka konstrukcija, površinska težina obodnih pregrada > 300 kg/m2;

prema DIN 4109, Beiblatt 1, tab. 1: Rw > 59 dB

Uz izvedbu naknadne postave ploča obloge, bez krute veze sa podlogom, neće doći do opadanja prosječne

zvučnoizolacijske moći pregrade, a kod izvedbe obloge pločama sa mineralnom vunom, može se očekivati poboljšanje

prosječne zvučnoizolacijske vrijednosti pregrade od najmanje 5 dB.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 24

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Doprinos ploča mineralne vune

Rw > 59 dB + 5 dB > 64 dB

prozori, staklene stijene, ostakljeni dijelovi (konstrukcija oznake PR1) :

Vanjski prozori, ostakljena vrata i staklene stijene su predviđene u plastificiranim aluminijskim okvirima s prekinutim

toplinskim mostom i toplinski poboljšanim svojstvima, ostakljenje IZO staklom dva sloja stakla min. 4+16+6 mm (4

LowE + 16/argon + 6). Minimalni razmak između stakla je 12 mm, jedno staklo mora biti low energie staklo (vanjska

strana unutarnjeg stakla), a međurazmak je ispunjen plinom argonom.

ZVUČNA IZOLACIJA gore opisane staklene stijene JE min. 33 dB (A) – prema specifikacijama proizvođača.

Predviđeni opisani prozori i staklene stijene mogu postići zvučno gušenje (prema laboratorijskim ispitivanjima) cca

Rw= 33 dB. Kao ugrađeni oni mogu postići zvučno gušenje Rw= 31 dB.

laki slagani krov (za konstrukcije oznaka K1) :

- biljni sloj kao SEDUM MIX – 100% gusto prorašteni sedum tepih na kokosovoj prostirci -

- supstrat za ekstenzivne zelene krovove (mješavina mineralnih sastojaka odgovarajuće

granulacije i tresetno – humusnog dodatka) – kao HUMOKOMPOVIT H6 R ili jednakovrijedan

materijal; debljina supstrata 10cm - 12 cm

10 - 12 cm

- prostirka za retenciju vode od kamene vune bez veziva, kao URBANSCAPE GREEN ROLL

ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: A1)

2 cm

- filterski sloj (kao tipa FIBRAN SF32 ili jednakovrijedan materijal), netkani polipropilenski

geotekstil termički vezanih vlakana (Klasa gorivosti po HRN EN 13501-1: E)

-

- drenažno akumulacijske ploče – EPS kadice; kao KEMPOR ZK60 ili jednakovrijedan

materijal (Klasa gorivosti po HRN EN 13501-1: E)

6 cm

- zaštitni sloj (kao FIBRAN skin SEAL ili jednakovrijedan materijal), difuzno otvorena

membrana za bržu odvodnju vode (Klasa gorivosti po HRN EN 13501-1: E)

-

- ploče ekstrudiranog polistirena XPS (cca 40 kg/m3); (deklarirana toplinska provodljivost po

HRN EN 12667: λD = 0,033 W/mK, Klasa gorivosti po HRN EN 13501-1: E), kao FIBRAN

XPS 300 L, d=50mm ili jednakovrijedan materijal, kao mehanička zaštita hidroizolacije

5 cm

- razdjelni sloj, filc od netkanog staklenog voala (300-500 g/m2) – geotekstil, termički obrađen

PES geotekstil (Klasa gorivosti po HRN EN 13501-1: E), postava prema uputama proizvođača

odabrane hidroizolacije

-

- sintetička krovna hidroizolacijska membrana za balastne prohodne, neprohodne i zelene

krovove na bazi TPO; jednoslojna hidroizolacijska membrana od sintetičke gume (FPO/TPO)

ojačana staklenim voalom (1200 – 1600 kg/m3) – kao Sarnafil TG66, Bauder Thermolin 018

ili jednakovrijedan materijal (Klasa gorivosti po HRN EN 13501-1: E)

potrebno je da odabrana hidroizolacija otporna na korijenje; izvedba sve prema uputama

proizvođača odabranog sustava hidroizolacije, toplinske izolacije i slojeva zelenog krova

0,18 cm

- tvrde ploče mineralne vune - kao Knauf Insulation ploča za ravne krovove SMARTROOF

TOP ili jednakovrijedan materijal, ploče polagane po slojevima na ravnoj armiranobetonskoj

ploči (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa

gorivosti po HRN EN 13501-1: A1)

10 cm

- tvrde ploče mineralne vune - kao Knauf Insulation ploča za ravne krovove SMARTROOF

THERMAL ili jednakovrijedan materijal, ploče polagane po slojevima na ravnoj

armiranobetonskoj ploči (deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,036

W/mK, Klasa gorivosti po HRN EN 13501-1: A1)

15 cm

- parna brana – kao Sarnavap 1000 E (polietilenska parna brana, obavezno sa ljepljenjem

preklopa i uz rubna ljepljenja) ili Knauf Insulation HOMESEAL LDS 100 AluPlus parna brana

(90 g/m2) ili jednakovrijedan materijal, postava parne brane u svemu prema uputama

0,02 – 0,4 cm

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 25

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

proizvođača (moguće ih je zabrtviti i ljepljivim trakama kao Soliplan i Solifit) (Klasa gorivosti

po HRN EN 13501-1: E)

- čelični trapezni profilirani lim, samonosivi, visine 155 mm

+ neventilirani zračni sloj

0,1 cm

- čelična krovna konstrukcija nosača IPE 550, L60/60/6 i HEA 120, sve prema statičkom

proračunu, zaštićeno protupožarnim premazom

cca 73 cm

- elastično ovješena potkonstrukcija limenih profila (CD 60x27) + neventilirani zračni prostor

između potkonstrukcije

(podkonstrukcija spuštenog stropa mora imati reakciju na požar A2 za ZPS3)

+ mineralna vuna između potkronstrukcije debljine min.5cm kao Knauf Insulation ECOSE filc

DECIBEL - deklarirana toplinska provodljivost po HRN EN 12667: λD = 0,038 W/mK, Klasa

gorivosti po HRN EN 13501-1: A1 ili jednakovrijedan materijal

≥ 5 cm

- spušteni strop na elastično ovješenoj metalnoj potkonstrukciji – akustičke ploče, perforirana

drvena obloga kao TOPAKUSTIK ploče GR 28/4 32/16 (drvo) odmaknute od podloge (+ 5cm

mineralne vune - gore opisana) (sve prema specifikacijama proizvođača)

ili perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE 12/25 Q – ploče

s akustičkim voalom (standardno crne boje)

ili jednakovrijedan materijal

(završna stropna obloga spuštenog stropa mora imati reakciju na požar najmanje D-d0 za ZPS3)

≥ 1,25 cm

promatrano kao jednostruka konstrukcija: Rw ≥ 45 dB.

ravni neprohodni krov - puna armiranobetonska ploča ukupne debljine 16 cm (konstrukcija oznake K2, K2a)

zaštitni sloj oblutaka 2200 kg/m3 8 cm 176 kg/m2

geotekstil 1000 kg/m3 0,02 cm 0,2 kg/m2

hidroizolacija (TPO ili PVC) 1200 kg/m3 0,15 cm 1,8 kg/m2

geotekstil 1000 kg/m3 0,02 cm 0,2 kg/m2

ekstrudirani polistiren 40 kg/m3 30 cm 12 kg/m2

parna brana 1000 kg/m3 0,4 cm 4 kg/m2

laki beton u padu 1200 kg/m3 4 cm 48 kg/m2

armiranobetonska ploča 2300 kg/m3 16 cm 368 kg/m2

produžna žbuka 1800 kg/m3 2 cm 36 kg/m2

M .= 646,2 kg/m2

M-1 .= 176 kg/m2

M-2 .= 452 kg/m2

prema DIN 4109, Beiblatt 1, tab. 12, stropna ploča površinske težine M = 452 kg/m2, s plivajućom podnom oblogom

Rw = 58 dB

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 26

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

e) VANJSKI IZVORI BUKE

U okolini građevine vanjski izvori buke potječu uglavnom od prometa obližnjim ulicama, Medvedgradskoj ulici s

koje postoji i kolni i pješački pristup na parcelu. Točni podaci o buci prometa nisu poznati, no s obzirom na kategoriju

prometnice i udaljenost najizloženijeg dijela fasade koja je najbliža izvoru buke, razina buke je približno izračunata

po izrazu:

Leq = 36,3 + 10 log n + 10 log 25 / d - K ; gdje je:

n - broj vozila na sat (prema statističkim pokazateljima);

d - udaljenost pročelja objekta od prometnice;

K - 0-15, ovisno o izloženosti objekta;

Za najbližu prometnicu (Medvedgradska ulica) uzima se n = 200, d = cca 14,50 m

Leq = 36,3 + 10 log 200 + 10 log 25 / 14,50

R w,potrebno = 61,7 dB na najizloženijem pročelju (učionica - zid s prozorom na istočnom pročelju najbližem navedenoj ulici).

Ove vrijednosti su približne i trebalo bi ih potvrditi mjernim ispitivanjima na terenu.

Proračun potrebnih rezultirajućih zvučnih izolacija pojedinih pročelja:

Prema metodologiji proračuna iz VDI 2719 - "Zvučna izolacija prozora i opreme" potrebna rezultirajuća, ponderirana

vrijednost zvučnog prigušenja vanjske pročeljne stijene, izračunava se prema izrazu.

Rw,potrebno = Le – Li + 10 log Sg/A + K + W

Od čega je:

Le = vanjska ekstremna buka: Le = Lvani + 3 dB = 61,7 + 3 = 64,7 dB

Li = dopuštena razina unutarnje buke: Li = 35 dB (danju) – predavaonica / učionica

Sg = ukupna vanjska površina pročelja: Sg = 19,65 m2

A = ekvivalentna apsorpcijska površina, približno: površina poda prostorije x 0,8 :

A = 23,44 x 0,8 = 18,75 m2

K = dodatna popravna vrijednost zavisna o spektru vanjske buke, tj. vrste prometa koji je uzrokuje: K = 3

W = dodatna popravna vrijednost vezana za kut upada buke: W = 0

R w,potrebno = 64,7 - 35 + 10 log 19,65 / 18,75 + 3 + 0

R w,potrebno = 32,9 dB

Treba udovoljiti zahtjevu:

Rw,srednje (stijene s prozorima) > Rw,potrebno

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 27

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Najviša dozvoljena razina buke u učionicama, prostorijama za edukaciju i dvorani iznosi 35 dB(A). Iz pretpostavljenih

vrijednosti razine buke uz pročelje zgrade i zvučno izolacione moći pregrade (vanjskog zida) dobivamo vrijednosti

razine buke u najizloženijim prostorijama građevine. Za najkritičniju pregradu (zid prostorije za edukaciju sa

prozorima i orijentacijom najviše okrenutima prema ulici), gdje je u proračun uzet zid sa najnepovoljnijim omjerom

plohe punog zida i prozora, sa:

Rzida= 61 dB; Rprozora= 31 dB;

Azida= 9,44 m²; Aprozora= 10,21 m²;

Prema izrazu iz DIN 4109:

R w,srednji = -10 * log ( 10,21 * 10 -3,1 + 9,44 * 10 -6,1 ) / 19,65

R w,srednji = 33,8 dB

Rw,srednje (stijene s prozorima) > Rw,potrebno

33,8 dB > 32,9 dB

zadovoljava

Razina buke u učionici / prostorijama za edukaciju / dvorani neće prelaziti dozvoljenu vrijednost razine buke od 35

dB(A).

OPASKA:

Ove vrijednosti su približne i trebalo bi ih potvrditi mjernim ispitivanjima na terenu.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 28

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

f) BUKA STROJARSKIH JEDINICA

Podaci o razini zvuka dobiveni su od projektanta strojarskih postrojenja, a odnose se na pravilno (prema proizvođačkoj

uputi i projektu) ugrađenu opremu (postolja na gumenim podlogama, antivibracijski podlošci, prigušivači ...), što je

detaljno opisano u strojarskim dijelovima glavnog projekta.

Potencijalna buka od strojarskih sustava:

DIZALICA TOPLINE (grijanje/hlađenje)

Vanjska jedinica 1 ima razinu buke od cca 57 dB(A) zvučnog tlaka na udaljenosti od 1m i visini od 1,5m od uređaja.

Vanjska jedinica 2 ima razinu buke od cca 63 dB(A) zvučnog tlaka na udaljenosti od 1m i visini od 1,5m od uređaja.

Smještene su u prostoriji spremišta u prizemlju zgrade.

+

KLIMA KOMORE (ventilacija)

Vanjska jedinica za učionice ima razinu buke od cca 64 dB(A) zvučnog tlaka na udaljenosti od 1m od uređaja.

Vanjska jedinica za dvoranu ima razinu buke od cca 64 dB(A) zvučnog tlaka na udaljenosti od 1m od uređaja.

Vanjski krovni odsisni ventilator ima razinu buke od cca 50 dB(A) zvučnog tlaka na udaljenosti od 1m od uređaja.

Smješteni su na ravnom neprohodnom krovu iznad kata nižeg dijela zgrade.

Unutarnje jedinice sustava: zvučna snaga [dB(A)]: 25 – 35 dB(A) na udaljenosti od 1,5m od uređaja.

Odsisni ventilatori sanitarija, paljenje sa rasvjetom + timer

- povremeni rad, silent box ventilatori: cca 45 dB(A)

Iz gore navedenih parametara dobivenih od projektanta strojarskog dijela projekta buka na svim vanjskim i unutarnjim

jedinicama grijanja, hlađenja, ventilacije i klimatizacije je ispod onih dopuštenih u zoni u kojoj se nalazi građevina

(Pravilnik o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i borave NN 145/04, tablica 1 gdje je

LRAeq = 50 dB(A) noću i LRAeq = 65 dB(A) danju, za zonu mješovite, pretežito poslovne namjene sa stanovanjem), te

jedinice (s bukom ispod 65 dB(A)) neće biti uzrok buke u okolišu.

Postoje izvori buke koji se prenose na okolinu i u prostor građevine kao i buka koja se prenosi sustavima ventilacije,

grijanja i hlađenja. Osnovni izvori buke su rotirajući elementi ventilatora, cirkulacionih crpki, ventilatori klima

uređaja, odsisa...

Za sprečavanje prijenosa nedozvoljenog nivoa buke strojarskim uređajima i sustavima predviđena je ugradnja

prigušivača buke. Brzine strujanja zraka u prostorima su u skladu s pravilima struke i kao takva zadovoljavaju

propisom predviđene uvjete u radnim i boravišnim prostorima.

Podaci o razini zvuka dobiveni su od projektanta strojarskih postrojenja, a odnose se na pravilno (prema proizvođačkoj

uputi i projektu) ugrađenu opremu (postolja na gumenim podlogama, antivibracijski podlošci, prigušivači ...), što je

detaljno opisano u strojarskim dijelovima glavnog projekta.

Buka od vanjskih jedinica ventilacije koje se nalaze na ravnom neprohodnom krovu iznad kata zgrade

Vanjske jedinice na krovu zgrade:

Prema podacima projektanta strojarskog projekta, vanjske jedinice emitiraju buku razine

Leq = 64 dB(A), na 1 m udaljenosti 2 komada

Leq = 50 dB(A), na 1 m udaljenosti 1 komad

Svi uređaji se postavljaju na čelične nosače koji se pričvršćuju na nosivu podnu ploču pomoću elastičnih podmetača

od tvrde gume. Oprema i instalacijski uređaji moraju biti antivibracijski učvršćeni.

Razina buke koju emitiraju ovi uređaji pri istovremenom radu iznosi:

Leq = 10 log (2x106,4 + 105,0) = 64,2 dB(A)

Buka od vanjskih jedinica ventilacije prema granici prostora (međi susjedne parcele)

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 29

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Prema izrazu za izračun buke za najbliže pročelje susjedne građevine odnosno do granice parcele (udaljenost izvora

buke od susjedne građevinske parcele) gdje je:

Li = razina zvuka na susjednoj (najbližoj) pregradi, odnosno granici parcele

LW = razina buke na "izvoru buke" = 64,2 dB(A) na udaljenosti od 1 m

r = udaljenost do granice parcele = 20,5 m

Li = 64,2 – 10 log 20,5 / 1,00

Li = 51,1 dB

Li = 51,1 dB(A) ≤ LRAeq,dop = 65 dB(A) danju,

što zadovoljava zahtjev postavljen Pravilnikom o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i

borave NN 145/04 (LRAeq = 50 dB(A) noću i LRAeq = 65 dB(A) danju, za zonu mješovite, pretežito poslovne namjene

sa stanovanjem).

Buka od vanjske jedinica ventilacije prema prostoru u građevini:

Najviše dopuštene ocjenske razine buke u zatvorenim prostorijama učionica po zonama buke prema članku 11.

Pravilnika o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i borave (NN 145/2004) je 35 dB(A).

Buka od strojarskih uređaja na pročelju zgrade

Li = razina zvuka na susjednoj (najbližoj) pregradi, odnosno granici parcele

LW = razina buke na "izvoru buke" = 64,2 dB(A) na udaljenosti od 1 m

r = udaljenost do zgrade = 1,50 m

Li = 64,2 – 10 log 1,50 / 1,00

Li = 62,4 dB

Za zid prema dvorani:

Vrijednost zvučne izolacije zida (konstrukcije oznake Z3) najbližeg bučnim strojarskim instalacijskim uređajima

iznosi Rwmin = 64 dB.

Buka od strojarskih uređaja, koja se smatra točkastim izvorom buke biti će niža od dopuštene razine u zvučno štićenom

prostoru:

Leq = 62,4 – 64 + 5 = 3,4 dB(A) < LRAeq,dop = 35 dB(A).

(5 dB dodaje se zbog mogućih posrednih puteva prijenosa buke i superponiranja s drugim izvorima).

Buka koju emitiraju vanjske jedinice sustava ventilacija neće ugroziti zvučno štićene prostore građevine u dogradnji

zgrade (dvorani).

Za krov prema prostoru ispod:

Vrijednost zvučne izolacije krova (konstrukcije oznake K2) najbližeg bučnim strojarskim instalacijskim uređajima

iznosi Rwmin = 58 dB.

Buka od strojarskih uređaja, koja se smatra točkastim izvorom buke biti će niža od dopuštene razine u zvučno štićenom

prostoru:

Leq = 62,4 – 58 + 5 = 9,4 dB(A) < LRAeq,dop = 35 dB(A).

(5 dB dodaje se zbog mogućih posrednih puteva prijenosa buke i superponiranja s drugim izvorima).

Buka koju emitiraju vanjske jedinice sustava ventilacija neće ugroziti zvučno štićene prostore građevine u dogradnji

zgrade (dvorani).

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 30

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Prema postojećem "starom" dijelu zgrade - učionice:

Buka od strojarskih uređaja na pročelju zgrade

Li = razina zvuka na susjednoj (najbližoj) pregradi, odnosno granici parcele

LW = razina buke na "izvoru buke" = 64,2 dB(A) na udaljenosti od 1 m

r = udaljenost do zgrade = 6,2 m

Li = 64,2 – 10 log 6,20 / 1,00

Li = 56,3 dB

Vrijednost zvučne izolacije zida (konstrukcije zid od opeke) najbližeg bučnim strojarskim instalacijskim uređajima

iznosi Rwmin = 47 dB – blok opeka debljine 25cm obostrano ožbukana.

Buka od strojarskih uređaja, koja se smatra točkastim izvorom buke biti će niža od dopuštene razine u zvučno štićenom

prostoru:

Leq = 56,3 – 47 + 5 = 14,3 dB(A) < LRAeq,dop = 35 dB(A).

(5 dB dodaje se zbog mogućih posrednih puteva prijenosa buke i superponiranja s drugim izvorima).

Buka koju emitiraju vanjske jedinice sustava ventilacija neće ugroziti zvučno štićene prostore građevine u dogradnji

zgrade (dvorani).

Buka od vanjskih jedinicae dizalice topline koje se nalaze u zasebnoj prostoriji u prizemlju zgrade

U prizemlju jugozapadnog dijela zgrade nalazi se prostorija spremišta u kojoj su smještene vanjske jedinice sustava

grijanja i hlađenja (vanjske jedinice dizalice topline) čija maximalna razina buke je 64 dB(A) (prema strojarskom

projektu), prilikom rada obje (2) jedinice istovremeno (maksimalan režim rada). Uređaji se nalaze u zatvorenom

prostoru.

Vanjske jedinice dizalice topline sustava grijanja i hlađenja postavljene su zasebnoj prostoriji.

Ukoliko mjerna ispitivanja na terenu utvrde prekomjernu buku unutar prostora, potrebno je unutrašnjost prostorije

izolirati zvučnom oblogom tj svi zidovi i plafon obložiti su oblogom i to sa površinski reljefnim piramidalnim

ORIFON PP-70 koji upija zvukove tako da u okolni prostor odlazi minimalna buka.

Vanjske jedinice ugrađuju se na tipske nosače preko antivibracionih podmetača, radi onemogućavanja prijenosa

vibracija.

Na otvorima prostorije spremišta u prizemlju potrebno je postaviti prigušivače buke da se prekomjerna buka iz

navedene prostorije ne bi širila u okolni prostor.

Podaci o razini zvuka dobiveni su od projektanta strojarskih postrojenja, a odnose se na pravilno (prema proizvođačkoj

uputi i projektu) ugrađenu opremu (postolja na gumenim podlogama, antivibracijski podlošci, prigušivači ...), što je

detaljno opisano u strojarskim dijelovima glavnog projekta.

Razina buke koju emitiraju ovi uređaji pri istovremenom radu iznosi:

Leq = 10 log (105,7 + 106,3) = 64,0 dB(A)

Razina buke u spremištu u kojem su smještene dizalice topline neće prelaziti ekvivalentnu razinu od

Leq = 64,0 dB(A).(izvor podataka: strojarski projekt)

Prema tome po odredbama HRN U.J6.201 ne radi se o "bučnoj" prostoriji jer je Leq < 70 dB(A).

Prostorija "strojarnice" prema prostoru iznad (kabinet)

Dozvoljena razina buke u prostorima od stacionarnih izvora buke: Leq = 35 dB(A).

buku u prostoru strojarnice je maksimalnog intenziteta do cca 64,0 dB(A)

pa Rw,potrebno = Le – Li + 10 log Sg/A + K + W

Od čega je:

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 31

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

LWi = 64,0 – 10 log 1/ 1 = 64,0 dB

Le = vanjska ekstremna buka: Le = Lvani + 3 dB = 64,0 + 3 = 67,0 dB

Li = dopuštena razina unutarnje buke: Li = 35 dB (danju)

Sg = ukupna vanjska površina poda: Sg = 15,35 m2

A = ekvivalentna apsorpcijska površina, približno: površina poda prostorije x 0,8 :

A = 15,17 x 0,8 = 12,14 m2

K = dodatna popravna vrijednost zavisna o spektru vanjske buke, tj. vrste prometa koji je uzrokuje: K = 3

W = dodatna popravna vrijednost vezana za kut upada buke: W = 0

R w,potrebno = 67,0 - 35 + 10 log 15,35 / 12,14 + 3 + 0

R w,potrebno = 36,0 dB

međukatna konstrukcija prema prostoru iznad - puna armiranobetonska ploča ukupne debljine 22 cm (konstrukcija

oznake M3):

plivajući cementni estrih 2200 kg/m3 4 cm 88 kg/m2

PE folija 1000 kg/m3 0,02 cm 0,2 kg/m2

ekspandirani polistiren EPS 150 25 kg/m3 5 cm 1,25 kg/m2

elastificirani polistiren EPS-T 15 kg/m3 2 cm 0,3 kg/m2

armiranobetonska ploča 2300 kg/m3 22 cm 506 kg/m2

neventilirani zrak+potkonstrukcija 0 kg/m3 5 cm 0 kg/m2

gipskartonske ploče 700 kg/m3 1,25 cm 8,75 kg/m2

M .= 604,5 kg/m2

M-1 .= 88 kg/m2

M-2 .= 506 kg/m2

prema DIN 4109, Beiblatt 1, tab. 12, stropna ploča površinske težine M = 506 kg/m2, s plivajućom podnom oblogom

(i spuštenim stropom, ali bez dodatne zvučne zaštite korištenjem mineralnom vunom – ne uzima se u obzir)

Rw = 59 dB

površinska težina obodnih pregrada u suterenu > 350 kg/m2, pa prema DIN 4109, Beiblatt 1, tab. 13

Rw = 59 dB + 1 dB = 60 dB

Rw= 60,0 dB > Rw,min= 36,0 dB

što zadovoljava zahtjev postavljen Pravilnikom o najvišim dozvoljenim razinama buke u sredini u kojima međukatna

konstrukcija zadovoljava zahtjev za zaštitom od buke.

Gornji proračun nije rađen s dodatkom koji daje postavljena zvučna obloga - površinski reljefne piramidalne ploče

ORIFON PP-70 koje dodatno snižavaju razinu buke.

Prostorija "strojarnice" prema granici prostora (međi susjedne parcele / zida učionica)

Izračun zvučno izolacione moći pregrade:

Promatrana stijena ima Rzida= 61 dB

pa uz izračun zvučne snage pregrade (zida prostorije spremišta / strojarnice u prizemlju):

LW = LWi - Rzida - 4 + 10 log Suk

Od čega je:

LWi = maksimalna razina buke u prostoriji strojarnice (prema strojarskom projektu) = 64 dB (A) na 1 m udaljenosti

Suk = ukupna vanjska površina pročelja: Suk = 17,34 m2

Lw = 64,0 - 61 - 4 + 10 log 17,34

Lw = 11,4 dB

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 32

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

zvučna snaga vanjske pregrade

Izračun opadanja intenziteta zvuka s udaljenošću od izvora. Prema izrazu: Li = LW – 10 log r/(r1) (dB) za najbliže

pročelje susjedne građevine odnosno do granice parcele (udaljenost strojarnice od granice parcele / zida učionica ja

5,70 m).

gdje je:

Li = razina zvuka na susjednoj (najbližoj) pregradi, odnosno granici susjedne parcele

LW = zvučna snaga pregrade = 11,4 dB

r = udaljenost cca = 5,70 m

Li = 11,4 – 10 log 5,70 / 1

Li = 3,8 dB

što zadovoljava zahtjev postavljen Pravilnikom o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i

borave NN 145/04 (LRAeq = 50 dB(A) noću i LRAeq = 65 dB(A) danju, za zonu mješovite, pretežito poslovne namjene

sa stanovanjem).

Gornji proračun nije rađen s dodatkom koji daje postavljena zvučna obloga - površinski reljefne piramidalne ploče

ORIFON PP-70 koje dodatno snižavaju razinu buke.

Na otvorima prostorije spremišta u prizemlju potrebno je postaviti prigušivače buke da se prekomjerna buka iz

navedene prostorije ne bi širila u okolni prostor.

Kako je buka na ostalim vanjskim i unutarnjim jedinicama grijanja, hlađenja i ventilacije ispod onih dopuštenih u zoni

u kojoj se nalazi građevina (Pravilnik o najvišim dozvoljenim razinama buke u sredini u kojima ljudi rade i borave

NN 145/04, tablica 1 su LRAeq = 50 dB(A) noću i LRAeq = 65 dB(A) danju, za zonu mješovite, pretežito poslovne

namjene sa stanovanjem), te jedinice (s bukom ispod 65 dB(A)) neće biti uzrok buke u okolišu.

Ove gore navedene vrijednosti su približne i ukoliko se ukaže potreba (više razine buke ugrađenih uređaja) trebalo bi

ih potvrditi mjernim ispitivanjima na terenu.

Obaveza je izvođača radova da dostavi nadzornom i projektnom timu na uvid i odobrenje, prije početka radova, u

trenutku kad bude poznat potencijalni dobavljač opreme, svu relevantnu tehničku dokumentaciju proizvođača glede

zvučno-izolacijskih karakteristika opreme i zvučno-izolacijskih rješenja, naročito u pogledu izvođenja akustičkih

obloga, prigušivača i specijalnih vrata, uključivo potrebne izvještaje o ispitivanju, odnosno certifikate. Za sve

prigušivače zvuka treba dostaviti jasne dokazne akustičke (zvučno-izolacijske) proračune s izračunatom konačnom

razinom buke. Proračun će se temeljiti na konkretnim proizvođačkim podacima o buci pojedinih elemenata opreme.

Eventualno prevelike razine buke i vibracija u odnosu na dozvoljene vrijednosti izvođač mora riješiti ugradnjom

efikasnijih prigušivača i boljih vibroizolatora, a ne smanjenjem protoka zraka, padom tlaka ili smanjenjem intenziteta

rada dotičnog uređaja.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 33

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

g) AKUSTIČKA OBRADA

VIŠENAMJENSKA UČIONICA

Predloženo je da se u podgleda stropa kao spušteni strop postavi obloga od akustičnih ploča – perforiranih

gipskartonskih ploča.

Kao akustička obloga predviđaju se perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE

12/25 Q – ploče s akustičkim voalom (standardno crne boje) koji zamjenjuje u smislu zvučne izolacije 5 cm mineralne

vune. Akustik ploče treba montirati na odmaku od podloge (stropa) cca 200 mm.

Akustik ploče – strop, odmak cca 200mm:

mHz 125 250 500 1000 2000 4000

α 0,58 0,92 0,99 0,86 0,84 0,64

Sloj zraka između podloge i akustičke obloge je ventiliran unutarnjim zrakom kako bi se spriječila neželjena

kondenzacija. Perforirana površina gore navedenih ploča je cca 18,1 %.

Nakon izvedbe građevine ovu vrijednost treba obavezno ispitati mjerenjem, te u slučaju rezultata koji ne bi zadovoljili

pretpostavljeni kriterij treba poduzeti odgovarajuće mjere.

(V= 244,73 m3 < 1000 m3)

Optimalno vrijeme odjeka u učionici ovisi o volumenu učionice. Volumen učionice je cca 244,73 m3, a optimalno

vrijeme odjeka varira od 0,65 sek. do 0,8 sek. za auditorij (maksimalno).

Vrijeme odjeka u dvorani odnosno učionici se računa prema formuli

Tsred = 0,16 x V / A i A = Σ Si * αi

gdje je:

Tsred = srednje vrijeme odjeka

V = volumen prostorije

A = ukupna apsorpcijska površina prostorije

Si = površina

αi = koeficijenti apsorpcije zvuka

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 34

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Površinska obrada s koeficijentima apsorbcije:

vrsta materijala površina frekv. 125 250 500 1000 2000 4000

zid - žbuka 93,31 m2 0,03 0,03 0,02 0,03 0,04 0,05

gipskarton Si * αi 2,7993 2,7993 1,8662 2,7993 3,7324 4,6655

pod -poliuretanski pod 78,44 m2 0,10 0,08 0,07 0,07 0,10 0,10

Si * αi 7,844 6,2752 5,4908 5,4908 7,844 7,844

strop - akustik ploče 78,44 m2 0,58 0,92 0,99 0,86 0,84 0,64

/perforirane (Rigiton) Si * αi 45,4952 72,1648 77,6556 67,4584 65,8896 50,2016

prozori - staklo 24,60 m2 0,10 0,04 0,03 0,02 0,02 0,02

Si * αi 2,46 0,984 0,738 0,492 0,492 0,492

cca 26 učenika 27 kom 0,33 0,33 0,44 0,44 0,46 0,46

.+ predavač Si * αi 8,91 8,91 11,88 11,88 12,42 12,42

drvena vrata 2,31 m2 0,14 0,14 0,06 0,06 0,10 0,10

Si * αi 0,3234 0,3234 0,1386 0,1386 0,231 0,231

A = Σ Si * αi 67,8 91,4567 97,7692 88,3 90,609 75,8541

Tsred = 0,163 * V / A .= 0,588086 0,436174 0,408012 0,451976 0,440254 0,525891

V = 244,73

Srednja vrijednost odjeka prostora Tsred = 0,475065 < Tsred, n = 0,8

OPASKA:

U ovom projektu je obrađen zahtjev za neželjenom bukom odnosno jekom koja se može pojaviti u dvoranama u

odnosu na završne obloge podova, zidova i sl.

Pozicija akustičnih obloga ne ovisi o vremenu odjeka u prostoru.

Pozicija akustičnih ploča je u ovom projektu stavljena prema slobodnim plohama zidova i stropova, ukoliko prilikom

izrade projekta interijera prostora dođe do drugačijeg riješena postave akustičkih obloga, novim proračunom će se dati

dokazi o ispunjenu zahtjeva za smanjenjem neželjenog odjeka.

Što se tiče akustike prostora (da je sami prostor dovoljno akustičan) potrebno je napraviti projekt akustike prostora.

Kod svakog interijerskog zahvata i promijene materijala obloga zidova, podova, stropova, postave namještaja i sl.

gore navedeni podatci i izračuni se mijenjaju.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 35

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

DVORANA ZA ERGONOMIJU

Predloženo je da se u podgleda stropa kao spušteni strop i kau unutarnja obloga zidova postavi obloga od akustičnih

ploča – perforiranih gipskartonskih ploča, .

Kao akustička obloga predviđaju se perforirane gipskartonske ploče kao Rigipssove ploče RIGITON AMBIANCE

12/25 Q – ploče s akustičkim voalom (standardno crne boje) koji zamjenjuje u smislu zvučne izolacije 5 cm mineralne

vune. Akustik ploče treba montirati na odmaku od podloge (stropa) cca 200 mm, dok su ploče od zida odmaknute cca

50 mm.

Akustik ploče – zid, odmak cca 50mm:

mHz 125 250 500 1000 2000 4000

α 0,10 0,34 0,69 0,88 0,78 0,64

Akustik ploče – strop, odmak cca 200mm:

mHz 125 250 500 1000 2000 4000

α 0,58 0,92 0,99 0,86 0,84 0,64

Sloj zraka između podloge i akustičke obloge je ventiliran unutarnjim zrakom kako bi se spriječila neželjena

kondenzacija. Perforirana površina gore navedenih ploča je 23,0 %.

Nakon izvedbe građevine ovu vrijednost treba obavezno ispitati mjerenjem, te u slučaju rezultata koji ne bi zadovoljili

pretpostavljeni kriterij treba poduzeti odgovarajuće mjere.

(V= 2.520 m3 < 10000 m3)

Prema važećim "Normativima s uputama o programiranju, projektiranju ...." (Prosvjetni vjesnik br. 4/1976.), za

nezauzete djeljive sportske dvorane traži se vrijeme odjeka od max. T=1,7 sek.

Optimalno vrijeme odjeka u dvorani za auditorij je cca 0,8 sek.

Vrijeme odjeka u dvorani odnosno učionici se računa prema formuli

Tsred = 0,16 x V / A i A = Σ Si * αi

gdje je:

Tsred = srednje vrijeme odjeka

V = volumen prostorije

A = ukupna apsorpcijska površina prostorije

Si = površina

αi = koeficijenti apsorpcije zvuka

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 36

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

Površinska obrada s koeficijentima apsorbcije:

vrsta materijala površina frekv. 125 250 500 1000 2000 4000

pod - pvc pod 420,00 m2 0,10 0,08 0,07 0,07 0,10 0,10

Si * αi 42 33,6 29,4 29,4 42 42

zid - akustik ploče 339,65 m2 0,10 0,34 0,69 0,88 0,78 0,64

/perforirane (Rigiton) Si * αi 33,965 115,481 234,3585 298,892 264,927 217,376

strop - akustik ploče 420,00 m2 0,58 0,92 0,99 0,86 0,84 0,64

/perforirane (Rigiton) Si * αi 243,6 386,4 415,8 361,2 352,8 268,8

prozori - staklo 124,60 m2 0,10 0,04 0,03 0,02 0,02 0,02

Si * αi 12,46 4,984 3,738 2,492 2,492 2,492

cca 15 učenika 16 kom 0,33 0,33 0,44 0,44 0,46 0,46

.+ predavač Si * αi 5,28 5,28 7,04 7,04 7,36 7,36

drvena vrata 15,75 m2 0,14 0,14 0,06 0,06 0,10 0,10

Si * αi 2,205 2,205 0,945 0,945 1,575 1,575

A = Σ Si * αi 339,5 547,95 691,2815 700,0 671,154 539,603

Tsred = 0,163 * V / A .= 1,209861 0,74963 0,594201 0,586826 0,61202 0,761226

V = 2.520,00

Srednja vrijednost odjeka prostora Tsred = 0,752294 < Tsred, n = 0,8 auditorij

Srednja vrijednost odjeka prostora Tsred = 0,752294 < Tsred, n = 1,7 sport

OPASKA:

U ovom projektu je obrađen zahtjev za neželjenom bukom odnosno jekom koja se može pojaviti u dvoranama u

odnosu na završne obloge podova, zidova i sl.

Pozicija akustičnih obloga ne ovisi o vremenu odjeka u prostoru.

Pozicija akustičnih ploča je u ovom projektu stavljena prema slobodnim plohama zidova i stropova, ukoliko prilikom

izrade projekta interijera prostora dođe do drugačijeg riješena postave akustičkih obloga, novim proračunom će se dati

dokazi o ispunjenu zahtjeva za smanjenjem neželjenog odjeka.

Što se tiče akustike prostora (da je sami prostor dovoljno akustičan) potrebno je napraviti projekt akustike prostora.

Kod svakog interijerskog zahvata i promijene materijala obloga zidova, podova, stropova, postave namještaja i sl.

gore navedeni podatci i izračuni se mijenjaju.

Investitor: ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA

MLINARSKA CESTA br.34, 10 000 ZAGREB Razina razrade: Glavni projekt

Naziv građevine: Dogradnja dvorane za ergonomiju radnog prostora u

zdravstvu pri Školi za medicinske sestre Mlinarska Vrsta projekta:

ARHITEKTONSKI PROJEKT

- Proračun fizikalnih svojstava zgrade

Lokacija: MLINARSKA CESTA br.34, 10 000 ZAGREB,

k.č.br. 333 k.o. CENTAR Mjesto i datum izrade: Zagreb, siječanj 2020. godine

Broj mape: 2 Dokumentacijski broj projekta (TD) : 26-2019 Zajednička oznaka projekta (ZOP) : 05-6/19 Str. 37

Dio mape: dio b Prikaz mjera zaštite od buke

"STUDIO LINEAMENTA"

d.o.o. za projektiranje, nadzor i usluge,

10 040 Zagreb - Dubrava, Čulinečka cesta 24A

Glavni projektant: Irena Gajšak Tonković, dipl.ing.arh.

Projektant: Željka Veseljak, dipl.ing.arh.

Suradnik: Neno Veseljak, CAD specijalist

h) ZAKLJUČAK

Predloženi sastavi pregrada zadovoljiti će propisima zahtijevane kriterije zaštite za zvučnu izolaciju od zračnog i gdje

je to potrebno, udarnog zvuka. Nivo buke unutar građevine biti će ispod najvećih dopuštenih vrijednosti kako od buke

unutar građevine, tako i od vanjske buke. Može se zaključiti da, glede zaštite od buke,

DOGRADNJA DVORANE ZA ERGONOMIJU RADNOG PROSTORA U ZDRAVSTVU PRI ŠKOLI ZA

MEDICINSKE SESTRE MLINARSKA U SVRHU USPOSTAVE REGIONALNOG CENTRA KOMPETENTNOSTI U STRUKOVNOM OBRAZOVANJU I

OSPOSOBLJAVANJU, SEKTOR ZDRAVSTVA

Investitora : ŠKOLA ZA MEDICINSKE SESTRE MLINARSKA, OIB: 63702214100

MLINARSKA CESTA br.34, 10 000 ZAGREB

na lokaciji : MLINARSKA CESTA br.34, 10 000 ZAGREB

k.č.br. 333 k.o. CENTAR

ZADOVOLJAVA.

U Zagrebu, siječanj 2020. godine

Projektant : Željka Veseljak, dipl.ing.arh.

DIREKTOR : Željka Veseljak, dipl.ing.arh.

"STUDIO LINEAMENTA"_____________________________________________________________________ d.o.o. za projektiranje, nadzor i usluge, 10 040 Zagreb - Dubrava, Čulinečka cesta br.24A